全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

Quality and Safety in the Phlebotomy Units of Medical Structures in Lubumbashi

DOI: 10.4236/oalib.1109966, PP. 1-10

Subject Areas: Diagnostics

Keywords: Phlebotomy, Quality, Security

Full-Text   Cite this paper   Add to My Lib

Abstract

A correct pre-analytical phase procedure is essential to obtain an adequate sample, unfortunately this phase is littered with many errors and risks. It is within this framework that we carried out a survey in the laboratories of the city of Lubumbashi, Likasi and Kolwezi in the Democratic Republic of Congo and this by a questionnaire imposed on the heads of the laboratories. 3588 responses were validated and analyzed. Our results showed that the first line of the health level is more represented by Health Centers (CS), followed by Polyclinics, Reference Health Centers (CRS) and Hospitals Reference Generals (RGH). We have observed variations in the implementation of the reference standards on good sampling practice both in terms of general organization and in terms of risk management, for the staff and for the patient. What requires training, the establishment of a quality management system in phlebotomy units.

Cite this paper

Ilunga, E. K. , Kambote, A. K. , Masanka, P. K. and Mposhy, E. P. M. (2023). Quality and Safety in the Phlebotomy Units of Medical Structures in Lubumbashi. Open Access Library Journal, 10, e9966. doi: http://dx.doi.org/10.4236/oalib.1109966.

References

[1]  Beastall, G.H. (2013) Adding Value to Laboratory Medicine: A Professional Responsibility. Clinical Chemistry and Laboratory Medicine (CCLM), 51, 221-227. https://doi.org/10.1515/cclm-2012-0630
[2]  Ngo, A., Gandhi, P. and Miller, W.G. (2017) Frequency that Laboratory Tests Influence Medical Decisions. The Journal of Applied Laboratory Medicine, 1, 410-414. https://doi.org/10.1373/jalm.2016.021634
[3]  Clinical and Laboratory Standards Institute (CLSI) (2007) Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture; Approved Standard—Sixth Edition. CLSI Document H3-A6 (ISBN 1-56238-650-6), Clinical and Laboratory Standards Institute.
[4]  Plebani, M., Sciacovelli, L., Marinova, M., Marcuccitti, J. and Chiozza, M.L. (2013) Quality Indicators in Laboratory Medicine: A Fundamental Tool for Quality and Patient Safety. Clinical Biochemistry, 46, 1170-1174. https://doi.org/10.1016/j.clinbiochem.2012.11.028
[5]  Chenge, M., Van der Vennet, J., Porignon, D., Luboya, N., Kabyla, I. and Criel, B. (2010) La carte sanitaire de la ville de Lubumbashi, République Démocratique du Congo. Partie I: Problématique de la couverture sanitaire en milieu urbain congolais. [The Health Map of Lubumbashi, Democratic Republic of the Congo. Part I: Problem of Health Coverage in Urban Congolese]. Global Health Promotion, 17, 63-74. (In French) https://doi.org/10.1177/1757975910375173
[6]  Bosongo, S., Chenge, F., Mwembo, A. and Crielnt, B. (2021) L’influence des prestations des médecins à la première ligne de soins sur le système intégré de district sanitaire à Kisangani, République Démocratique du Congo: Une étude qualitative. Pan African Medical Journal, 39, Article 215. https://doi.org/10.11604/pamj.2021.39.215.25737
[7]  Bosongo, S.I., Mukalenge, F.C., Tambwe, A.M. and Criel, B. (2021) [Les médecins prestataires à la première ligne des soins dans la ville de Kisangani en République Démocratique du Congo: Vers une typologie]. African Journal of Primary Health Care & Family Medicine, 13, a2617. (In French) https://doi.org/10.4102/phcfm.v13i1.2617
[8]  Lima-Oliveira, G., Lippi, G., Salvagno, G.L., Montagnana, M., Picheth, G. and Guidi, G.C. (2012) Impact of the Phlebotomy Training Based on CLSI/NCCLS H03-a6—Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture. Biochemia Medica, 22, 342-351. https://doi.org/10.11613/BM.2012.036
[9]  Lima-Oliveira, G., Volanski, W., Lippi, G., Picheth, G. and Guidi, G.C. (2017) Pre-Analytical Phase Management: A Review of the Procedures from Patient Preparation to Laboratory Analysis. Scandinavian Journal of Clinical and Laboratory Investigation, 77, 153-163. https://doi.org/10.1080/00365513.2017.1295317
[10]  World Health Organization (WHO)/International Labour Organization (ILO) (2008) Guidelines on Post Exposure Prophylaxis (PEP) to Prevent Human Immunodeficiency Virus (HIV) Infection. OMS/BIT.
[11]  Health Protection Authority (HPA) (2005) Eye of the Needle—Surveillance of Significant Occupational Exposure to Blood-Borne Viruses in Healthcare Personnel. HPA.
[12]  Sacar, S., et al. (2006) Poor Hospital Infection Control Practice in Hand Hygiene, Glove Utilization, and Usage of Tourniquets. American Journal of Infection Control, 34, 606-609. https://doi.org/10.1016/j.ajic.2006.02.006
[13]  Rourke, C., Bates, C. and Read, R. (2001) Poor Hospital Infection Control Practice in Blood Sampling and Use of Tourniquets. Journal of Hospital Infection, 49, 59-61. https://doi.org/10.1053/jhin.2001.1038
[14]  Kermode, M. (2004) Health Worker Safety Is a Prerequisite for Injection Safety in Developing Countries. International Journal of Infectious Diseases, 8, 325-327. https://doi.org/10.1016/j.ijid.2004.03.005
[15]  WHO (2010) Guidelines on Drawing Blood: Best Practices in Phlebotomy.
[16]  Kiechle, F.L. (2007) So You’re Going to Collect a Blood Specimen: An Introduction to Phlebotomy. 12th Edition, College of American Pathologists.
[17]  Organisation mondiale de la Santé (2005) Gestion des déchets d’activités de soins solides dans les centres de soins de santé primaires: Guide d’aide à la décision. Organisation mondiale de la Santé. http://whqlibdoc.who.int/publications/2005/9242592749_fre.pdf
[18]  Corey, K.E., et al. (2009) Pilot Study of Postexposure Prophylaxis for Hepatitis C virus in Healthcare Workers. Infection Control and Hospital Epidemiology, 30, 1000-1005. https://doi.org/10.1086/605718
[19]  Picheansanthian, W. and Chotibang, J. (2015) Glove Utilization in the Prevention of cross Transmission: A Systematic Review. JBI Database of Systematic Reviews and Implementation Reports, 13, 188-230. https://doi.org/10.11124/01938924-201513040-00013
[20]  Hegde, S. (2020) Which Type of Personal Protective Equipment (PPE) and which Method of Donning or Doffing PPE Carries the Least Risk of Infection for Healthcare Workers? Evidence-Based Dentistry, 21, 74-76. https://doi.org/10.1038/s41432-020-0097-3
[21]  Verbeek, J.H., Rajamaki, B., Ijaz, S., Sauni, R., Toomey, E., Blackwood, B., Tikka, C., Ruotsalainen, J.H. and Balci, F.S.K. (2020) Personal Protective Equipment for Preventing Highly Infectious Diseases Due to Exposure to Contaminated Body Fluids in Healthcare Staff. Cochrane Database of Systematic Reviews, 4, CD011621. https://doi.org/10.1002/14651858.CD011621.pub4
[22]  WHO. (2010) WHO Guidelines on Drawing Blood: Best Practices in Phlebotomy. World Health Organization.
[23]  Cruickshank-Quinn, C., Zheng, L.K., Quinn, K., Bowler, R., Reisdorph, R. and Reisdorph, N. (2018) Impact of Blood Collection Tubes and Sample Handling Time on Serum and Plasma Metabolome and Lipidome. Metabolites, 8, Article 88. https://doi.org/10.3390/metabo8040088
[24]  Dhondt, J.L. (2001) Le chaînon manquant: Qualité de l’identification et phase pré-analytique [The Missing Link: Quality in the Identification and Preanalytic Phase]. Annales de Biologie Clinique, 59, 231-232. (In French)
[25]  Valenstein, P.N. and Sirota, R.L. (2004) Identification Errors in Pathology and Laboratory Medicine. Clinics in Laboratory Medicine, 24, 979-996, https://doi.org/10.1016/j.cll.2004.05.013
[26]  Green, S.F. (2013) The Cost of Poor Blood Specimen Quality and Errors in Preanalytical Processes. Clinical Biochemistry, 46, 1175-1179. https://doi.org/10.1016/j.clinbiochem.2013.06.001
[27]  Salgueiro-Oliveira, A.S., Costa, P.J.D.S., Braga, L.M., Graveto, J.M.G.N., Oliveira, V.S. and Parreira, P.M.S.D. (2019) Health Professionals’ Practices Related with Tourniquet Use during Peripheral Venipuncture: A Scoping Review. Revista Latino-Americana de Enfermagem, 27, e3125.
[28]  Grohmann, M., Schomakers, L., Wolschendorf, F., Grosch, J., Lindner, S. and Witte, A.K. (2020) Reduced Bacterial Contamination Rates Detected on Silicone Tourniquets Compared to Conventional Tourniquets in Clinical Routine. BMC Infectious Diseases, 20, Article No. 247. https://doi.org/10.1186/s12879-020-04975-y

Full-Text


comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133

WeChat 1538708413