Monte Carlo software MCNPX was used to simulate the influence of geometric factors and doping concentration of CLYC-6 scintillator detector on detection efficiency and luminous efficiency. It is found that with the increase of CLYC-6 crystal size, the detection efficiency increases nonlinearly, while the luminous efficiency decreases nonlinearly, and the changing trend of both decreases with the increase of crystal size. Under different particle radiation energies, the thickness of the CLYC-6 crystal is 2.54 cm, the bottom diameter is 17.78 cm, and the doping concentration (Ce3 ) is 0.5%. The luminescence efficiency reaches the maximum value, and it has good detection efficiency. This result can provide a reference for the development of the CLYC-6 detector.
Cite this paper
Wu, P. , Feng, M. and Song, B. (2022). The Influence of Geometric Factors of CLYC-6 Crystal on Detection Efficiency and Luminous Efficiency. Open Access Library Journal, 9, e9096. doi: http://dx.doi.org/10.4236/oalib.1109096.
Smith, M.B., Achtzehn, T., et al. (2015) Fast Neutron Measurements Using Cs2LiYCl6:Ce (CLYC) Scintillator. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 784, 162-167.
https://doi.org/10.1016/j.nima.2014.09.021
D’Olympia, N., Chowdhury, P., Lister, C.J., Glodo, J., Hawrami, R., Shah, K. and Shirwadkar, U. (2013) Pulse-Shape Analysis of CLYC for Thermal Neutrons, Fast Neutrons, and Gamma-Rays. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 714, 121-127. https://doi.org/10.1016/j.nima.2013.02.043
Woolf, R.S., Wulf, E.A., Phlips, B.F., Chowdhury, P. and Jackson, E.G. (2020) Identification of Internal Radioactive Contaminants in Elpasolites (CLYC, CLLB, CLLBC) and Other Inorganic Scintillators. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 954, Article ID: 161228. https://doi.org/10.1016/j.nima.2018.09.063
Glodo, J., Higgins, W.M., van Loef, E.V.D. and Shah, K.S. (2008) Scintillation Properties of 1 Inch Cs2LiYCl6: Ce Crystals. IEEE Transactions on Nuclear Science, 55, 1206-1209. https://doi.org/10.1109/TNS.2007.913467
Martinez, T., Pérez de Rada, A., et al. (2013) Characterization of a CLYC Detector for Underground Experiments. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 906, 150-158. https://doi.org/10.1016/j.nima.2018.07.087
Glodo, J., et al. (2013) Fast Neutron Detection with Cs2LiYCl6. IEEE Transactions on Nuclear Science, 60, 864-870. https://doi.org/10.1109/TNS.2012.2227499
D’Olympia, N., et al. (2012) Optimizing Cs2LiYCl6 for Fast Neutron Spectroscopy. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 694, 140-146.
https://doi.org/10.1016/j.nima.2012.07.021
Huang, K. and Zhong, W.Y. (2018) MC Simulation of BaBrI (Eu) Scintillator Light Yield and Detection Efficiency. Nuclear Electronics and Detection Technology, 38, 865-869.
Qin, J.G. and Zheng, P. (2016) Cs2LiYCl6:Ce Scintillator Detector γ Response and Characteristics. National Annual Conference on Nuclear Electronics and Nuclear Detection Technology, Chengdu, 9.
Ren, G.H. and Yang, F. (2017) The Research History and Current Situation of Halide Scintillation Crystals. SCIENTIA SINICA Technologica, 47, 1149-1164.
https://doi.org/10.1360/N092017-00108
Zhong, D.S. and Cai, X.J. (2019) Simulation Study on the Influence of Geometric Factors of LaBr3 Crystal on Luminous Efficiency and Detection Efficiency. Nuclear Electronics and Detection Technology, 39, 664-667.