全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

XRF Analysis of Impurity Metal Elements in Iron Base Alloy

DOI: 10.4236/oalib.1107846, PP. 1-5

Subject Areas: Nuclear Physics

Keywords: Iron Base Alloy, XRF, Matrix Effect, Linear Regression

Full-Text   Cite this paper   Add to My Lib

Abstract

The content of Si, Mn, V, Cu and other impurity elements in tool steel samples was analyzed by wavelength dispersive X-ray fluorescence spectrometry (XRF). Using Ag target X-ray tube and the SDD detector (FWHM < 135 eV@5.9 keV). The best working conditions of the instrument are tested before measurement, including tube pressure, flow, filter used and measuring time. The repeatability of the instrument is verified to meet the standard. Finally, the detection limit of the instrument is tested. In the analysis and comparison, linear regression method is used to eliminate the matrix effect among the elements in the sample, and it is found that the multiple linear regression method has a good correction effect on the matrix effect. The results show that the average relative errors of Si, Mn, V and Cu are 3.24%, 3.05%, 0.29% and 0.59% respectively by using the optimal linear regression analysis. The method improves the control requirements of impurity elements in iron base alloy.

Cite this paper

Zhang, B. , Shi, J. , Jiang, Y. , Zhou, J. and Li, S. (2021). XRF Analysis of Impurity Metal Elements in Iron Base Alloy. Open Access Library Journal, 8, e7846. doi: http://dx.doi.org/10.4236/oalib.1107846.

References

[1]  Chen, X.Q. (2010) Study on XRF Method and Technology for Analyzing the Content of Main Elements in Copper Alloys. Chengdu University of Technology, Chengdu.
[2]  Ji, A., Zhuo, S.J. and Tao, G.Y. (2001) Application of Energy Dispersive X-Ray Fluorescence Spectroscopy in Iron and Steel Industry. Iron and Steel, 10, 64-68.
[3]  Tian, W.H., Wang, Z.Q. and Zhang, M. (2008) Determination of Molybdenum, Lead, Iron and Copper in Molybdenum Ore by Energy Dispersive X-Ray Fluorescence Spectrometry. Rock Ore Test, 3, 236.
[4]  Zhu, L.P., Li, X.X. and Sun, H.R. (2020) Discussion and Application of Detection Methods of Al, Cu, Mn, Si and P in Ferrotitanium. Scientific and Technological Innovation, 31, 22-23.
[5]  Liang, X.Y. (2011) Quantitative Analysis of Standard Free X-Ray Fluorescence Spectrometer. Hangzhou University of Electronic Science and Technology, Hangzhou.
[6]  Li, D. (2008) Study on the Application of EDI-Ⅲ X-Ray Tube in Energy Dispersive X-Ray Fluorescence Analysis. Chengdu University of Technology, Chengdu.

Full-Text


comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133

WeChat 1538708413