The angular response function F(θ, φ) is used as an airborne gamma spectrometer to measure the basic physical quantity of the contribution of each nuclide to the total dose rate by the all-energy peak method, which is facing the difficulty of experimental calibration. In this paper, the Monte Carlo program MCNP5 is used to calculate the full-energy peak angle response function F(θ, φ) of a single NaI(Tl) crystal (40 cm × 10 cm × 5 cm) to Cs-137. It has been verified that when the point source is directly below the spectrometer, the relative error between the dose rate calculated by a single crystal γ spectrometer using the all-energy peak method and the dose rate measured by the high-pressure ionization chamber does not exceed 15%. When the distance between the crystal and the point source is 7 m and the elevation and azimuth angles are both 45°, the relative error between the two is 13.891%, which verifies the feasibility of the analog scale of the angular response function.
Cite this paper
Wan, Q. , Hu, Y. , Xu, R. and Liu, Q. (2020). Monte Carlo Simulation of Angular Response Function of Airborne Gamma Spectrometer. Open Access Library Journal, 7, e06638. doi: http://dx.doi.org/10.4236/oalib.1106638.
Li, H.Y., Jiang, M.Z., Chen, G.S., Quan, X.D. and Chang, S.S. (2018) The Brilliant Achievements and Technological Innovation of Airborne Radioactivity Survey in China. The Material Exploration and the Chemical Exploration, No. 42, 645-652.
Wang, J.D., Gao, G.L., Yang, J.Z., Cai, W.J., An, Z.W. and Ni, W.C. (2017) The Estimation of Radon Background in the Data Processing of UAV Gamma-ray Spectrometry. Uranium Ore Geology, 33, 37-44.
Wang, N.P., Pei, S.Y., Huang, Y., Xiao, L., Liu, S.M., Gao, B.L. and Cheng, Y.X. (2005) Research on and Application of Methods for Gamma-Ray Spectrometry in Environmental Monitoring. Radiation Protection, No. 6, 29-38.
He, J. and Yang, Z.W. (2014) Measurement of γ Absorption Dose Rate through Measuring the Full Energy Peak of γ Spectrum. Nuclear Technology, 37, 49-54.
Liu, X.H., Zhang, Y.X., Gu, R.K. and Shen, E.S. (1998) Calibration of Angle Response of a NaI(Tl) Airborne Spectrometer to 137 Cs and 60 Co Point Sources on the Ground. Radiation Protection, No. 6, 16-25.
Billings, S. and Hovgaard, J. (1999) Modeling Detector Response in Airborne Gamma-Ray Spectrometry. Geophysics, 64, 1378-1392.
https://doi.org/10.1190/1.1444643
Qian, N., Wang, D.Z., Bai, Y.F., Liu, C., Zhang, Y. and Yang, Y.L. (2010) Dead Layer Thickness and Efficiency Function of Point Source for HPGe Detector. Nuclear Technology, 33, 25-30.