全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

The Effect of Anion-Exchange-Treated Water Containing Phosphonic Acid and Benzotriazole on Copper Corrosion Resistance

DOI: 10.4236/ojcm.2026.163005, PP. 73-84

Keywords: Copper, Carbon Film, pitting Corrosion, Anion Exchange-Treated Water, Benzotriazole, Phosphonic Acid

Full-Text   Cite this paper   Add to My Lib

Abstract:

Copper tubes have high thermal conductivity, excellent workability, and corrosion resistance. For these reasons, they are widely used in air conditioning equipment. However, copper tubes can corrode due to interactions between the material and its environment. The carbon film-dependent pitting corrosion is caused by the relationship between the carbon film on the inner surface of copper tubes and the quality of the water flowing them. Phosphonic acid (HEDP) and benzotriazole (BTA) have been reported to suppress pitting corrosion. Additionally, it has been reported that water quality components such as calcium ions (Ca2+), silicate ions ( SiO 4 4? ) and bicarbonate ions ( HCO 3 ? ) are effective. Tap water contains various ions, including chloride ion (Cl?), sulphate ion ( SiO 4 2? ) and bicarbonate ions ( HCO 3 ? ). Cl? and SiO 4 2? are known as corrosive ions. Conversely, HCO 3 ? is known as corrosion-inhibiting ions. Anion-exchange treatment is a technology for reducing corrosive ions in tap water. It has been reported that anion-exchange treated water inhibits corrosion in carbon steel pipes used within the same system as copper tubes. However, there are few reports on its corrosion-inhibiting effect on copper tubes. This study focused on the effect of anion-exchange treated water on copper pitting corrosion. The test specimens used different amounts of carbon film. The test solution

References

[1]  Yamada, Y., Mori, A., Hatanaka, R., Atsumi, T. and Nakao, N. (1998) Pitting Corrosion of Copper Coiled Tubes in the Air Conditioning System Having the Open Heat Storage Water Tank. Zairyo-to-Kankyo, 47, 723-728.
https://doi.org/10.3323/jcorr1991.47.723
[2]  Osami, S., Kajikawa, H., Sasaki, M., Yamada, Y., Toda, I. and Iitsuka, M. (2002) Effect of Residual Carbon Deposit on Corrosion Behavior of Copper Tube in Air Conditioner Water. Journal of the Institute of Copper, 41, 131-135.
[3]  Yamada, Y., Seri, O., Tagashira, K. and Nagata K. (2002) Pitting Corrosion of Cop-per in Aqueous Solutions Containing Phosphonic Acid as an Inhibitor. Zairyo-to-Kankyo, 51, 12-16.
[4]  Aramaki, K. (1976) Introduction to Corrosion Inhibitors. Corrosion Engineering, 25, 693-702.
https://doi.org/10.3323/jcorr1974.25.11_693
[5]  Yamada, Y., Seri, O., Tagashira, K. and Nagata, K. (1993) Pitting Corrosion of Copper in Aqueous Solutions Containing Phosphonic Acid as an Inhibitor. Zairyo-to-Kankyo, 42, 558-563.
https://doi.org/10.3323/jcorr1991.42.558
[6]  Yamada, Y., Kuboki, S., Wakabayashi, K. (2006) Moundless Type Pitting Corrosion of Copper Tube for Cold and Hot Water Service System. Zairyo-to-Kankyo, 45, 180-184.
[7]  Sakai, M., Yamagishi, N. and Matsumoto, N. (2012) Corrosion Behavior and Pitting Morphology of Copper in Synthetic Freshwater Containing Silica. Zairyo-to-Kankyo, 61, 48-51.
https://doi.org/10.3323/jcorr.61.48
[8]  Yamaguchi, Y., Sasaki, T., Kuratani, M., Iyasu, T., Yamada, Y. and Sakurada, O. (2022) Effects of Silicate on Corrosion Resistance of Copper Tube by Cooling Water System Water Treatment Chemical. Journal of Japan Institute of Copper, 61, 154-158.
[9]  Yuichi, O. and Taneno, M. (1996) Anticorrosive Effect of Anion Exchange Treatment on Carbon Steel and Copper in a Closed Cooling Water System. Proceeding of Japan Corrosion Conference, Suita, 16-18 October 1996, 261-264.
[10]  Takasaki, S. and Yamada, Y. (2007) Effects of Temperature and Aggressive Anions on Corrosion of Carbon Steel in Potable Water. Corrosion Science, 49, 240-247.
https://doi.org/10.1016/j.corsci.2006.05.035
[11]  Nakamura, Y., Yamada, I., Matsukawa, Y., Okazaki, S. and Asakura S. (2021) Crrosion Countermeasure for Building Equipment in Water Pitting System Part 1-Corrosion Prevention Nature for Carbon Steel in Tap Waters Treated with Anion Exchange Resin. Journal of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan, 297, 57-65.
[12]  Ikeda, T., Kano, Y., Sasaki, T., Yamaguchi, Y., Imaizumi, Y., Tanaka, N., Yamada, Y. and Sakurada, O (2023) Comparison and Evaluation between the Rapid Evaluation Test and the Field Evaluation for Assessing the Pitting Corrosion Resistance of Copper Tube. Journal of Japan Institute of Copper, 62, 90-94.
[13]  Yamada, Y., Seri, O., Tagashira, K. and Nagata, K. (1993) Effect of Cl-On the Pitting Corrosion of Copper in a Phosphonic Acid Solution. Journal of the Surface Finishing Society of Japan, 44, 753-756.
https://doi.org/10.4139/sfj.44.753
[14]  Kano, Y., Ikeda, I., Iyasu, T., Yamaguchi, Y., Yamada, Y. and Sakurada, O. (2022) Relationship between Corrosion Form and Elution Behavior of Copper Tubes Surfaces with Different Residual Carbon Amounts. Materials Sciences and Applications, 13, 595-602.
https://doi.org/10.4236/msa.2022.1312037
[15]  Takahashi, F., Yamaguchi, Y., Sugiura, K., Iyasu, T., Yamada, Y. and Sakurada, O. (2025) Effect of Hydrogen Carbonate Ion on Copper Pitting Corrosion in the Presence of Phosphonic Acid and Corrosion Inhibitors. Materials Transactions, 66, 1226-1229.
https://doi.org/10.2320/matertrans.mt-d2025001

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133