- 2010
Medical ICU Insulin Infusion ProtocolsDOI: 10.1002/jhm.816 Abstract: AbstractPURPOSE:To compare the safety and efficacy of continuous insulin infusion (CII) via a computer‐guided and a standard paper form protocol in a medical intensive care unit (ICU).METHODS:Multicenter randomized trial of 153 ICU patients randomized to CII using the Glucommander (n = 77) or a standard paper protocol (n = 76). Both protocols used glulisine insulin and targeted blood glucose (BG) between 80 mg/dL and 120 mg/dL.RESULTS:The Glucommander resulted in a lower mean BG value (103 ± 8.8 mg/dL vs. 117 ± 16.5 mg/dL, P < 0.001) and in a shorter time to reach BG target (4.8 ± 2.8 vs.7.8 hours ± 9.1 hours, P < 0.01), and once at target resulted in a higher percentage of BG readings within target (71.0 ± 17.0% vs. 51.3 ± 19.7%, P < 0.001) than the standard protocol. Mean insulin infusion rate in the Glucommander was similar to the standard protocol (P = 0.12). The percentages of patients with ≥1 episode of B
|