Purpose: To evaluate the influence of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA) on proton density fat fraction (PDFF) using multiple vendors’ DIXON methods in a multicenter, multivendor phantom study. Materials and Methods: Pairs of phantoms with varying fat volume percentages (0, 5, 10, 15, 20, 30, 40, and 50) and Gd-EOB-DTPA concentrations (0 and 0.4 mM) were constructed. The phantom without Gd-EOB-DTPA in each pair was defined as the precontrast phantom, and the corresponding phantom with Gd-EOB-DTPA in each pair was defined as the postcontrast phantom. The phantoms were scanned via three vendors’ DIXON techniques to determine PDFFs. Agreement between PDFFs determined in precontrast and postcontrast phantoms was evaluated via Bland–Altman analysis. Results: Mean differences (precontrast PDFF - postcontrast PDFF) and limits of agreement were Philips 5.1% (−0.8% to 11.0%), Siemens 6.1% (−0.9% to 13.1%), and GE 1.3% (−1.2% to 3.9%). Conclusions: PDFFs measured using the three vendors’ DIXON techniques were smaller in the postcontrast phantoms than in the corresponding precontrast phantoms regardless of different scanning parameters, because T1 bias was improved by Gd-EOB-DTPA.
References
[1]
Caussy, C., Reeder, S.B., Sirlin, C.B. and Loomba, R. (2018) Noninvasive, Quantitative Assessment of Liver Fat by MRI-PDFF as an Endpoint in NASH Trials. Hepatology, 68, 763-772. https://doi.org/10.1002/hep.29797
[2]
Ratziu, V., Bonyhay, L., Di Martino, V., et al. (2002) Survival, Liver Failure, and Hepatocellular Carcinoma in Obesity-Related Cryptogenic Cirrhosis. Hepatology, 35, 1485-1493. https://doi.org/10.1053/jhep.2002.33324
[3]
Adams, L.A., Lymp, J.F., St Sauver, J., et al. (2005) The Natural History of Nonalcoholic Fatty Liver Disease: A Population-Based Cohort Study. Gastroenterology, 29, 113-121. https://doi.org/10.1053/j.gastro.2005.04.014
[4]
West, J. and Card, T.R. (2010) Reduced Mortality Rates Following Elective Percutaneous Liver Biopsies. Gastroenterology, 139, 1230-1237. https://doi.org/10.1053/j.gastro.2010.06.015
[5]
Reeder, S.B. and Sirlin, C.B. (2010) Quantification of Liver Fat with Magnetic Resonance Imaging. Magnetic Resonance Imaging Clinics of North America, 18, 337-357. https://doi.org/10.1016/j.mric.2010.08.013
[6]
Liu, C.Y., McKenzie, C.A., Yu, H., Brittain, J.H. and Reeder, S.B. (2007) Fat Quantification with IDEAL Gradient Echo Imaging: Correction of Bias from T(1) and Noise. Magnetic Resonance in Medicine, 58, 354-364. https://doi.org/10.1002/mrm.21301
[7]
Meisamy, S., Hines, C.D., Hamilton, G., et al. (2011) Quantification of Hepatic Steatosis with T1-Independent, T2-Corrected MR Imaging with Spectral Modeling of Fat: Blinded Comparison with MR Spectroscopy. Radiology, 258, 767-775. https://doi.org/10.1148/radiol.10100708
[8]
Kühn, J.P., Hernando, D. and Muñoz del Rio, A. (2012) Effect of Multipeak Spectral Modeling of Fat for Liver Iron and Fat Quantification: Correlation of Biopsy with MR Imaging Results. Radiology, 265, 133-142. https://doi.org/10.1148/radiol.12112520
[9]
Hayashi, T., Fukuzawa, K., Yamazaki, H., et al. (2018) Multicenter, Multivendor Phantom Study to Validate Proton Density Fat Fraction and T2* Values Calculated Using Vendor-Provided 6-Point DIXON Methods. Clinical Imaging, 51, 38-42. https://doi.org/10.1016/j.clinimag.2018.01.011
[10]
Park, C.C., Hamilton, G., Desai, A., et al. (2017) Effect of Intravenous Gadoxetate Disodium and Flip Angle on Hepatic Proton Density Fat Fraction Estimation with Six-Echo, Gradient-Recalled-Echo, Magnitudebased MR Imaging at 3T. Abdominal Radiology (NY), 42, 1189-1198. https://doi.org/10.1007/s00261-016-0992-4
[11]
Hayashi, T., Fukuzawa, K., Kondo, H., et al. (2018) Influence of Gd-EOB-DTPA on T1 Dependence of the Proton Density Fat Fraction Using Magnetic Resonance Spectroscopy. Radiological Physics and Technology, 11, 338-344. https://doi.org/10.1007/s12194-018-0466-1
[12]
Hayashi, T., Fukuzawa, K., Kondo, H., et al. (2017) Influence of Gd-EOB-DTPA on Proton Density Fat Fraction Using the Six-Echo Dixon Method in 3 Tesla Magnetic Resonance Imaging. Radiological Physics and Technology, 10, 483-488. https://doi.org/10.1007/s12194-017-0420-7
[13]
Fukuzawa, K., Hayashi, T., Takahashi, J., et al. (2017) Evaluation of Six Point Modified Dixon and Magnetic Resonance Spectroscopy for Fat Quantification: A Fat-Water-Iron Phantom Study. Radiological Physics and Technology, 10, 349-358. https://doi.org/10.1007/s12194-017-0410-9
[14]
Hamilton, G., Middleton, M.S., Cunha, G.M. and Sirlin, C.B. (2013) Effect of Gadolinium-Based Con Trast Agent on the Relaxation Properties of Water and Fat in Human Liver as Measured in Vivo by 1H MRS. Proceedings International Society for Magnetic Resonance in Medicine, 21, 1516.