串级不稳定时滞过程的内模控制器设计
Design Method of IMC Controllers for Unstable Cascade Processes with Time Delay

DOI: 10.3969/j.issn.1001-0548.2017.01.007

Keywords: 二自由度控制,串级控制,内模控制,不稳定时滞过程

Full-Text   Cite this paper   Add to My Lib

Abstract:

针对串级不稳定时滞过程研究了内模控制器的设计方法。该方法副回路采用传统内模控制,能及时快速消除内环干扰对系统整体控制性能的影响;主回路采用一种二自由度内模控制结构,将设定值跟随特性与干扰抑制特性解耦,控制器的参数整定不需要在两种特性之间折中选择,克服了传统内模控制的不足。理论分析和仿真结果表明,该方法不仅能有效减少控制器的个数,而且可使系统同时获得良好的设定值跟随特性、干扰抑制特性和鲁棒性。

References

[1]  KAYA I, TAN N, ATHERTON D P. Improved cascade control structure for enhanced performance[J]. Journal of Process Control, 2007, 17(1):3-16.
[2]  ALFARO V M, VILANOVA R, ARRIETA O. Robust tuning of two-degree-of-freedom (2-DoF) PI/PID based cascade control systems[J]. Journal of Process Control, 2009, 19(10):1658-1670.
[3]  LIU Tao, ZHANG Wei-dong, GU Dan-ying. IMC-based control strategy for open-loop unstable cascade processes[J]. Industrial & Engineering Chemistry Research, 2005, 44(4):900-909.
[4]  LIU Tao, ZHANG Wei-dong, GU Dan-ying. Analytical design for a class of open-loop unstable cascade (control) systems[J]. Journal of Control and Decision, 2004, 19(8):872-876.
[5]  KAYA I, ATHERTON D P. Use of smith predictor in the outer loop for cascaded control of unstable and integrating processes[J]. Industrial & Engineering Chemistry Research, 2008, 47(6):1981-1987.
[6]  UMA S, CHIDAMBARAM M, RAO A S. Enhanced control of unstable cascade processes with time delays using a modified smith predictor[J]. Industrial & Engineering Chemistry Research, 2009, 48(6):3098-3111.
[7]  PADHAN D G, MAJHI S. Modified smith predictor based cascade control of unstable time delay processes[J]. ISA Transactions, 2012, 51(1):95-104.
[8]  GARCIA C E, MORARI M. Internal model control. A unifying review and some new results[J]. Industrial & Engineering Chemistry Process Design and Development, 1982, 21(2):308-323.
[9]  SHAMSUZZOHA M, LEE M. Analytical design of enhanced PID filter controller for integrating and first order unstable processes with time delay[J]. Chemical Engineering Science, 2008, 63(10):2717-2731.
[10]  MANFRED M, ZAFIRIOU E. Robust process control[M]. Englewood Cliffs, N J, USA:Prentice Hall, 1989.
[11]  ZHANG W, GU D, WANG W, et al. Quantitative performance design of a modified smith predictor for unstable processes with time delay[J]. Industrial & Engineering Chemistry Research, 2004, 43(1):56-62.
[12]  SARAF V, ZHAO F, BEQUETTE B W. Relay autotuning of cascade-controlled open-loop unstable reactors[J]. Industrial & Engineering Chemistry Research, 2003, 42(20):4488-4494.
[13]  LEE Y, SUNGGOOK O H, PARK S. Enhanced control with a general cascade control structure[J]. Industrial & Engineering Chemistry Research, 2002, 41(11):2679-2688.
[14]  KAYA I, ATHERTON D P. Improved cascade control structure for controlling unstable and integrating processes[C]//Decision and Control, 2005 European Control Conference.[S.l.]:IEEE, 2005:7133-7138.
[15]  KAYA I. Improving performance using cascade control and a Smith predictor[J]. Isa Transactions, 2001, 40(3):223-234.