DOI: 10.3969/j.issn.1005-3026.2014.04.026, PP. 569-573

Keywords: 血管介入,机器人,临床手术,控制精度,实时运动

Full-Text   Cite this paper   Add to My Lib

Abstract:

传统的血管介入手术需要医生徒手操控导管,存在医生受辐射和人为因素影响手术质量等弊端.针对该问题,设计了用于辅助医生手术的主从式遥操作血管介入机器人.根据临床手术的要求,基于模块化理念,分别对机器人的从端推进机构、主端操控装置进行了结构设计,为主从模式的实现做了相关的软、硬件开发;对机器人样机进行了必要的性能测试,证实了该机器人具有小于1mm的运动控制精度和044ms的主从运动实时性.结果表明:该机器人系统解决了传统手术中的问题,在功能和性能上完全满足血管介入手术的要求,具有较高的临床使用价值.

References

[1]  Ma X,Guo S X,Xiao N,et al.Development of a novel robotassisted cather system with force feedback[C]//Proceeding of the 2011 IEEE International Conference on Mechatronics and Automation.Beijing,2011:107/111.
[2]  Wang T M,Zhang D P,Liu D.Remotecontrolled vascular interventional surgery robot[J].The International Journal of Medical Robotics and Computer Assisted Surgery,2010,2:194/201.
[3]  卢旺盛,刘达,田增民,等.血管介入手术机器人的关键技术分析[J].生物医学工程研究,2009,28(4):303/306.(Lu Wangsheng,Liu Da,Tian Zengmin,et al.The analysis of key technologies of intravascular intervention surgical robot[J].Journal of Biomedical Engineering Research,2009,28(4):303/306.)
[4]  Mack M J.Minimally invasive and robotic surgery[J].Journal of the American Medical Association,2001,285(5):568/572.
[5]  段星光,陈悦,于华涛.微创血管介入手术机器人控制系统与零位定位装置设计[J].机器人,2012,34(2):129/136.(Duan Xingguang,Chen Yue,Yu Huatao.Design of the control system and home point position device for minimally invasive interventional surgery robot[J].Robot,2012,34(2):129/136.)
[6]  Beyar R,Gruberg L,Roguin A,et al.Remotecontrol percutaneous coronary interventions[J].Journal of American College of Cardiology,2006,47(2):296/300.
[7]  Saliba W,Vivek Y.Atrial fibrillation ablation using a robotic catheter remote control system:initial human experience and longterm followup results[J].Journal of the American College of Cardiology,2008,51(24):2407/241.
[8]  Guo S X,Kondo H,Wang J,et al.A new catheter operating system for medical applications[C]//International Conference on Complex Medical Engineering.Beijing:IEEE/ICME,2007:82/86.
[9]  Saliba W,Cummings J E,Zhang Y,et al.A novel robotic catheter remote control system[J].Feasibility and Safety of Transseptal Puncture and Endocardial Catheter Navigation,2006,17(10):1102/1105.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133