Horseradish Peroxidase Biosensor to Detect Zinc Ions in Aqueous Solutions

DOI: 10.4236/ojab.2014.31001, PP. 1-7

Keywords: Horseradish Peroxidase, Maize Tassel, Multiwalled Carbon Nanotubes, Metal Biosensor, Zn2+

Full-Text   Cite this paper   Add to My Lib

Abstract:

Maize tassel-multiwalled carbon nanotube (MT-MWCNT) composite has been used as a matrix for physical adsorption of horseradish peroxidase (HRP) onto the surface of a glassy carbon electrode through electrostatic interactions. The HRP/MT-MWCNT biosensor was applied for the detection of Zn2+ in aqueous solution. The biosensor designed was able to determine Zn2+ in the range of 0.35 - 12 mg/L with a detection limit of 7.5 μg/L. The inhibition was found to be reversible and uncompetitive when data were modeled using the Dixon and Cornish-Bowden plots. The biosensor was found to have good repeatability, reproducibility and high selectivity. The developed biosensor can be used to detect other HRP inhibiting trace metal ions.

References

[1]  R. B. Thompson, B. P. Maliwal, V. L. Feliccia, C. A. Fierke and K. McCall, “Determination of Picomolar Concentrations of Metal Ions Using Fluorescence Anisotropy: Biosensing with a “Reagentless” Enzyme Transducer,” Analytical Chemistry, Vol. 70, No. 22, 1998, pp. 4717-4723. http://dx.doi.org/10.1021/ac980864r
[2]  I. Bontidean, C. Berggren, G. Johansson, et al., “Detection of Heavy Metal Ions at Femtomolar Levels Using Protein-Based Biosensors,” Analytical Chemistry, Vol. 70, No. 19, 1998, pp. 4162-4169. http://dx.doi.org/10.1021/ac9803636
[3]  S. Han, M. Zhu, Z. Yuan and X. Li, “A Methylene Blue-Mediated Enzyme Electrode for the Determination of Trace Mercury(II), Mercury(I), Methylmercury, and Mercuryglutathione Complex,” Biosensors and Bioelectronics, Vol. 16, No. 1-2, 2001, pp. 9-16. http://dx.doi.org/10.1016/S0956-5663(00)00114-7
[4]  M. R. Guascito, C. Malitesta, E. Mazzotta and A. Turco, Inhibitive Determination of Metal Ions by an Amperometric Glucose Oxidase Biosensor: Study of the Effect of Hydrogen Peroxide Decomposition,” Sensors and Actuators B: Chemical, Vol. 131, No. 2, 2008, pp. 394-402. http://dx.doi.org/10.1016/j.snb.2007.11.049
[5]  E. Ghica, R. C. Carvalho, A. Amine and C. M. A. Brett, “Glucose Oxidase Enzyme Inhibition Sensors for Heavy Metals at Carbon Film Electrodes Modified with Cobalt or Copper Hexacyanoferrate,” Sensors and Actuators B: Chemical, Vol. 178, 2013, pp. 270-278. http://dx.doi.org/10.1016/j.snb.2012.12.113
[6]  S. Rodriguez-Mozaz, M. J. L. De Alda and D. Barcelo, “Biosensors as Useful Tools for Environmental Analysis and Monitoring,” Analytical and Bioanalytical Chemistry, Vol. 386, No. 4, 2006, pp. 1025-1041. http://dx.doi.org/10.1007/s00216-006-0574-3
[7]  Z. S. Yang, W. L. Wu, X. Chen and Y. C. Liu, “An Amperometric Horseradish Peroxidase Inhibition Biosensor for the Determination of Phenylhydrazine,” Analytical Science, Vol. 24, No. 7, 2008, pp. 895-899. http://dx.doi.org/10.2116/analsci.24.895
[8]  M. Moyo, J. O. Okonkwo and N. M. Agyei, “A Novel Hydrogen Peroxide Biosensor Based on Adsorption of Horseradish Peroxidase onto a Nanobiomaterial Composite Modified Glassy Carbon Electrode,” Electroanalysis, Vol. 25, No. 8, 2013, pp. 1946-1954. http://dx.doi.org/10.1002/elan.201300165
[9]  M. Moyo, L. Chikazaza, B. C. Nyamunda and U. Guyo, “Adsorption Batch Studies on the Removal of Pb(II) Using Maize Tassel Based Activated Carbon,” Journal of Chemistry, Vol. 2013, Article ID: 508934, 8 p.
[10]  P. Raghu, T. M. Reddy, B. E. K. Swamy, B. N. Chandrashekar, K. Reddaiah and M. Sreedhar, “Development of AChE Biosensor for the Determination of Methyl Parathion and Monocrotophos in Water and Fruit Juices: A Cyclic Voltammetric Study,” Journal of Electroanalytical Chemistry, Vol. 665, 2012, pp. 76-82. http://dx.doi.org/10.1016/j.jelechem.2011.11.020
[11]  Z. Li and N. Hu, “Direct Electrochemistry of Heme Proteins in Their Layer-By-Layer Films with Clay Nanoparticles,” Journal of Electroanalytical Chemistry, Vol. 558, 2003, pp. 155-165. http://dx.doi.org/10.1016/S0022-0728(03)00390-5
[12]  Y. Liu, H. Liu and N. Hu, “Core-Shell Nanocluster Films of Hemoglobin and Clay Nanoparticle: Direct Electro-chemistry and Electrocatalysis,” Biophyscal Chemistry, Vol. 117, No. 1, 2005, pp. 27-37
[13]  M. E. Ghica and C. M. A. Brett, “Glucose Oxidase Inhibition in Poly (Neutral red) Mediated Enzyme Biosensors for Heavy Metal De-termination,” Microchimica Acta, Vol. 163, No. 3-4, 2008, pp. 185-193. http://dx.doi.org/10.1007/s00604-008-0018-1
[14]  X. Wang, S. Xia, J. Zhao, H. Zhao and J. N. Renault, “Inhibitive Determination of Heavy Metal Ions by Conductometric Nitrate Reductase Biosensor,” Chem. Res. Chinese Universities, 2009, Vol. 25, pp. 443-445
[15]  F. Arduini, A. Amine, D. Moscone and G. Palleschi, “Reversible Enzyme Inhibition-Based Biosensors: Applica-tions and Analytical Improvement through Diagnostic Inhibition,” Analytical. Letters, Vol. 42, No. 9, 2009, pp. 1258-1293. http://dx.doi.org/10.1080/00032710902901913
[16]  G. L. Turdean, “Design and Development of Biosensors for the Detection of Heavy Metal Toxicity,” International Journal of Electrochemistry, Vol. 2011, 2011, pp. 1-15. http://dx.doi.org/10.4061/2011/343125
[17]  A. Cornish-Bowden, “A Simple Graphical Method for Determining the Inhibition Constants of Mixed, Uncompetitive and Non-Competitive Inhibitors,” Biochemical Journal, Vol. 137, 1974, pp. 143-144.
[18]  M. Dixon, “The Determination of Enzyme Inhibitor Constants,” Biochemistry Journal. Vol. 55, No. 1, 1953, pp. 170-171.
[19]  A. Amine, H. Mohamed, I. Bourais and G. Palleschi, “Enzyme Inhibition-Based Biosensors for Food Safety and Environmental Monitoring,” Biosensors and Bioelectronics, Vol. 21, No. 8, 2006, pp. 1405-1423. http://dx.doi.org/10.1016/j.bios.2005.07.012
[20]  Y. Yang, M. Yang, H. Wang, J. Jiang, G. Shen and R. Yu, “An Amperometric Horseradish Peroxidase Inhibition Biosensor Based on a Cysteamine Self-Assembled Monolayer for the Determination of Sulphides.” Sensors and Actuators B: Chemical, Vol. 102, No. 1, 2004, pp. 162-168. http://dx.doi.org/10.1016/j.snb.2004.04.016
[21]  USEPA, “USEPA Maximum Contaminant Level Goals and National Primary Drinking Water Regulations for Lead and Copper,” Final Rule, Federal Register, Vol. 56, No. 110, 1991, pp. 26460-26469.
[22]  World Health Organization (WHO), “Guidelines for Drinking Water Quality,” 3rd Edition, 2004, WHO, Geneva.