Abstract:

Electrical impedance tomography (EIT) has the potential to provide a low cost and safe imaging modality for clinically monitoring patients being treated with mechanical ventilation. Variations in reconstruction algorithms at different clinical settings, however, make interpretation of regional ventilation across institutions difficult, presenting the need for a unified algorithm for thoracic EIT reconstruction. Development of such a consensual reconstruction algorithm necessitates a forward model capable of predicting surface impedance measurements as well as electric fields in the interior of the modeled thoracic volume. In this paper, we present an anatomically realistic forward solver for thoracic EIT that was built based on high resolution MR image data of a representative adult. Accuracy assessment of the developed forward solver in predicting surface impedance measurements by comparing the predicted and observed impedance measurements shows that the relative error is within the order of 5%, demonstrating the ability of the presented forward solver in generating high-fidelity surface thoracic impedance data for thoracic EIT algorithm development and evaluation. 1. Introduction Electrical impedance tomography (EIT) is a medical imaging technique in which an image of the conductivity distribution in a part of the body is inferred from surface electrical potentials resulting from application of a number of current patterns through the body. Because of its noninvasiveness, portability, and low cost, EIT has been actively investigated since the 1970s [1] and finds potential applications in a wide variety of clinical areas including monitoring of lung problems such as pulmonary edema [2] or pneumothorax [3], non-invasive monitoring of heart function and blood flow [4], localization of epileptic foci [5], investigating gastric emptying [6], and measuring local internal temperature increases associated with hyperthermia therapy [7]. Lately, similar technique has also been proposed for stenotic plaque detection [8]. Among those, one of the most promising applications of EIT is continuous regional pulmonary monitoring, especially for monitoring patients being treated with mechanical ventilation. Mechanical ventilation is indicated when the patient’s spontaneous ventilation is inadequate and is one of the most common interventions administered in intensive care. Mechanical ventilation can improve the prognosis for acute phase patients; however, it also often leads to potential complications such as ventilator-associated lung injury (VALI) and

References

[1]  R. P. Henderson and J. G. Webster, “Impedance camera for spatially specific measurements of thorax,” IEEE Transactions on Biomedical Engineering, vol. 25, no. 3, pp. 250–254, 1978.
[2]  F. Yang and R. P. Patterson, “The contribution of the lungs to thoracic impedance measurements: a simulation study based on a high resolution finite difference model,” Physiological Measurement, vol. 28, no. 7, pp. S153–S161, 2007.
[3]  E. L. V. Costa, C. N. Chaves, S. Gomes, M. A. Beraldo, M. S. Volpe, M. R. Tucci, et al., “Real-time detection of pneumothorax using electrical impedance tomogyaphy,” Critical Care Medicine, vol. 36, no. 4, pp. 1230–1238, 2008.
[4]  H. J. Smit, A. V. Noordegraaf, J. T. Marcus, A. Boonstra, P. M. de Vries, and P. E. Postmus, “Determinants of pulmonary perfusion measured by electrical impedance tomography,” The European Journal of Applied Physiology, vol. 92, no. 1-2, pp. 45–49, 2004.
[5]  K. Boone, A. M. Lewis, and D. S. Holder, “Imaging of cortical spreading depression of EIT-implications for localization of elieptic foci,” Physiological Measurement, supplement 2a, pp. A189–A198, 1994.
[6]  C. T. Soulsby, M. Khela, E. Yazaki, D. F. Evans, E. Hennessy, and J. Powell-Tuck, “Measurements of gastric emptying during continuous nasogastric infusion of liquid feed: electric impedance tomography versus gamma scintigraphy,” Clinical Nutrition, vol. 25, no. 4, pp. 671–680, 2006.
[7]  M. J. Moskowitz, T. P. Ryan, K. D. Paulsen, and S. E. Mitchell, “Clinical implementation of electrical impedance tomography with hyperthermia,” International Journal of Hyperthermia, vol. 11, no. 2, pp. 141–149, 1995.
[8]  F. Yang and R. P. Patterson, “A novel impedance-based tomography approach for stenotic plaque detection: a simulation study,” International Journal of Cardiology, vol. 144, no. 2, pp. 279–283, 2010.
[9]  I. Frerichs, J. Scholz, and N. Weiler, “10: electrical impedance tomography and its perspectives in intensive care medicine,” in Yearbook of Intensive Care and Emergency Medicine, pp. 437–447, Springer, Heidelberg, Germany.
[10]  A. Adler, J. H. Arnold, R. Bayford et al., “GREIT: a unified approach to 2D linear EIT reconstruction of lung images,” Physiological Measurement, vol. 30, no. 6, pp. S35–S55, 2009.
[11]  F. Yang and R. Patterson, “Optimal transvenous coil position on active-can single-coil ICD defibrillation efficacy: a simulation study,” Annals of Biomedical Engineering, vol. 36, no. 10, pp. 1659–1667, 2008.
[12]  J. Malmivuo and R. Plonsey, “7: Volume source and volume conductor,” in Bioelectromagnetism: Principles and Applications of Bioelectric and Omagnetic Fields, pp. 405–407, University Press, New York, NY, USA, 1995.
[13]  W. R. B. Lionheart, “EIT reconstruction algorithms: pitfalls, challenges and recent developments,” Physiological Measurement, vol. 25, no. 1, pp. 125–142, 2004.
[14]  P. K. Kauppinen, J. A. Hyttinen, and J. A. Malmivuo, “Sensitivity distributions of impedance cardiography using band and spot electrodes analyzed by a three-dimensional computer model,” Annals of Biomedical Engineering, vol. 26, no. 4, pp. 694–702, 1998.
[15]  A. L. de Jongh, E. G. Entcheva, J. A. Replogle, R. S. Booker III, B. H. Kenknight, and F. J. Claydon, “Defibrillation efficacy of different electrode placements in a human thorax model,” Pacing and Clinical Electrophysiology, vol. 22, no. 1, pp. 152–157, 1999.
[16]  F. Aguel, J. C. Eason, N. A. Trayanova, G. Siekas, and M. G. Fishler, “Impact of transvenous lead position on active-can ICD defibrillation: a computer simulation study,” Pacing and Clinical Electrophysiology, vol. 22, no. 1, pp. 158–164, 1999.
[17]  J. Wtorek, “Relations between components of impedance cardiogram analyzed by means of finite element model and sensitivity theorem,” Annals of Biomedical Engineering, vol. 28, no. 11, pp. 1352–1361, 2000.
[18]  D. Mocanu, J. Kettenbach, M. O. Sweeney, R. Kikinis, B. H. Kenknight, and S. R. Eisenberg, “A comparison of biventricular and conventional transvenous defibrillation: a computational study using patient derived models,” Pacing and Clinical Electrophysiology, vol. 27, no. 5, pp. 586–593, 2004.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133