全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
Biosensors  2013 

Fast and Sensitive Interferon-γ Assay Using Supercritical Angle Fluorescence

DOI: 10.3390/bios3010108

Keywords: one-step immunoassay, interferon-gamma, supercritical angle fluorescence, polymer test tube

Full-Text   Cite this paper   Add to My Lib

Abstract:

We present an immunoassay for Interferon-γ (IFN-γ) with a limit of detection of 1.9 pM (30 pg/mL) and a linear concentration range spanning three orders of magnitude. The developed one-step assay takes only 12 min and can replace the time-consuming and labor-intensive enzyme-linked immunosorbent assay (ELISA). The solid-phase sandwich assay is performed on a new measurement system comprising single-use test tubes and a compact fluorescence reader. The polymer tubes contain an optical configuration for the detection of supercritical angle fluorescence, allowing for highly sensitive real-time binding measurements.

References

[1]  Choi, J.W.; Kwang, W.O.; Thomas, J.H.; Heineman, W.R.; Halsall, H.B.; Nevin, J.H.; Helmicki, A.J.; Henderson, H.T.; Ahn, C.H. An integrated microfluidic biochemical detection system for protein analysis with magnetic bead-based sampling capabilities. Lab Chip?2002, 2, 27–30, doi:10.1039/b107540n.
[2]  Lacharme, F.; Vandevyver, C.; Gijs, M.A. Full on-chip nanoliter immunoassay by geometrical magnetic trapping of nanoparticle chains. Anal. Chem.?2008, 80, 2905–2910, doi:10.1021/ac7020739.
[3]  Nam, J.M.; Thaxton, C.S.; Mirkin, C.A. Nanoparticle-based bio-bar codes for the ultrasensitive detection of proteins. Science?2003, 301, 1884–1886, doi:10.1126/science.1088755.
[4]  Bruls, D.M.; Evers, T.H.; Kahlman, J.A.; van Lankvelt, P.J.; Ovsyanko, M.; Pelssers, E.G.; Schleipen, J.J.; de Theije, F.K.; Verschuren, C.A.; van der Wijk, T.; van Zon, J.B.; Dittmer, W.U.; Immink, A.H.; Nieuwenhuis, J.H.; Prins, M.W. Rapid integrated biosensor for multiplexed immunoassays based on actuated magnetic nanoparticles. Lab Chip?2009, 9, 3504–3510, doi:10.1039/b913960e. 20024029
[5]  Gaster, R.S.; Hall, D.A.; Nielsen, C.H.; Osterfeld, S.J.; Yu, H.; Mach, K.E.; Wilson, R.J.; Murmann, B.; Liao, J.C.; Gambhir, S.S.; Wang, S.X. Matrix-insensitive protein assays push the limits of biosensors in medicine. Nat. Med.?2009, 15, 1327–1332, doi:10.1038/nm.2032. 19820717
[6]  Kurita, R.; Yokota, Y.; Sato, Y.; Mizutani, F.; Niwa, O. On-chip enzyme immunoassay of a cardiac marker using a microfluidic device combined with a portable surface plasmon resonance system. Anal. Chem.?2006, 78, 5525–5531, doi:10.1021/ac060480y.
[7]  Mauriz, E.; Calle, A.; Manclús, J.; Montoya, A.; Lechuga, L. Multi-analyte SPR immunoassays for environmental biosensing of pesticides. Anal. Bioanal. Chem.?2007, 387, 1449–1458, doi:10.1007/s00216-006-0800-z.
[8]  Ni, J.; Lipert, R.J.; Dawson, G.B.; Porter, M.D. Immunoassay readout method using extrinsic Raman labels adsorbed on immunogold colloids. Anal. Chem.?1999, 71, 4903–4908, doi:10.1021/ac990616a.
[9]  Zheng, G.; Patolsky, F.; Cui, Y.; Wang, W.U.; Lieber, C.M. Multiplexed electrical detection of cancer markers with nanowire sensor arrays. Nat. Biotech.?2005, 23, 1294–1301, doi:10.1038/nbt1138.
[10]  Deiss, F.; LaFratta, C.N.; Symer, M.; Blicharz, T.M.; Sojic, N.; Walt, D.R. Multiplexed sandwich immunoassays using electrochemiluminescence imaging resolved at the single bead level. J. Am. Chem. Soc.?2009, 131, 6088–6089, doi:10.1021/ja901876z. 19361216
[11]  Li, M.; Sun, Y.; Chen, L.; Li, L.; Zou, G.; Zhang, X.; Jin, W. Ultrasensitive eletrogenerated chemiluminescence immunoassay by magnetic nanobead amplification. Electroanalysis?2010, 22, 333–337, doi:10.1002/elan.200900351.
[12]  Kerman, K.; Endo, T.; Tsukamoto, M.; Chikae, M.; Takamura, Y.; Tamiya, E. Quantum dot-based immunosensor for the detection of prostate-specific antigen using fluorescence microscopy. Talanta?2007, 71, 1494–1499, doi:10.1016/j.talanta.2006.07.027.
[13]  Fan, R.; Vermesh, O.; Srivastava, A.; Yen, B.K.; Qin, L.; Ahmad, H.; Kwong, G.A.; Liu, C.C.; Gould, J.; Hood, L.; Heath, J.R. Integrated barcode chips for rapid, multiplexed analysis of proteins in microliter quantities of blood. Nat. Biotech.?2008, 26, 1373–1378, doi:10.1038/nbt.1507.
[14]  Ruckstuhl, T.; Winterflood, C.M.; Seeger, S. Supercritical angle fluorescence immunoassay platform. Anal. Chem.?2011, 83, 2345–2350, doi:10.1021/ac1032758.
[15]  Winterflood, C.M.; Ruckstuhl, T.; Verdes, D.; Seeger, S. Nanometer axial resolution by three-dimensional supercritical angle fluorescence microscopy. Phys. Rev. Lett.?2010, 105, 108103:1–108103:4.
[16]  Ruckstuhl, T.; Verdes, D.; Winterflood, C.M.; Seeger, S. Simultaneous near-field and far-field fluorescence microscopy of single molecules. Opt. Express?2011, 19, 6836–6844, doi:10.1364/OE.19.006836. 21451711
[17]  Ruckstuhl, T.; Rankl, M.; Seeger, S. Highly sensitive biosensing using a supercritical angle fluorescence (SAF) instrument. Biosens. Bioelectron.?2003, 18, 1193–1199, doi:10.1016/S0956-5663(02)00239-7.
[18]  Krieg, A.; Laib, S.; Ruckstuhl, T.; Seeger, S. Fast detection of single nucleotide polymorphisms (SNPs) by primer elongation with monitoring of supercritical-angle fluorescence. ChemBioChem?2004, 5, 1680–1685, doi:10.1002/cbic.200400044.
[19]  V?lim?ki, H.S.; Pulli, T.; Tappura, K. Applying total internal reflection excitation and super critical angle fluorescence detection to a morphine assay. J. Fluoresc.?2010, 20, 1003–1008, doi:10.1007/s10895-010-0647-8.
[20]  J?nsson, C.; Aronsson, M.; Rundstr?m, G.; Pettersson, C.; Mendel-Hartvig, I.; Bakker, J.; Martinsson, E.; Liedberg, B.; MacCraith, B.; Ohman, O.; Melin, J. Silane-dextran chemistry on lateral flow polymer chips for immunoassays. Lab Chip?2008, 8, 1191–1197, doi:10.1039/b800297e.
[21]  Ruckstuhl, T.; Enderlein, J.; Jung, S.; Seeger, S. Forbidden light detection from single molecules. Anal. Chem.?2000, 72, 2117–2123, doi:10.1021/ac991358k.
[22]  Kurzbuch, D.; Bakker, J.; Melin, J.; J?nsson, C.; Ruckstuhl, T.; MacCraith, B. A biochip reader using super critical angle fluorescence. Sens. Actuator. B Chem.?2009, 137, 1–6, doi:10.1016/j.snb.2008.12.057.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133