oalib

OALib Journal期刊

ISSN: 2333-9721

费用:99美元

投稿

时间不限

( 4 )

( 2026 )

( 2025 )

( 2024 )

自定义范围…

匹配条件: “analisador infravermelho de gases” ,找到相关结果约1000条。
列表显示的所有文章,均可免费获取
第1页/共1000条
每页显示 条
Vigor of canola seeds through quantification of CO2 emission Vigor de sementes de canola quantificado pela libera o de CO2
Jo?o Alexandre Lopes Dranski,Artur Soares Pinto Júnior,Neusa Francisca Michelon Herzog,Ubirajara Contro Malavasi
Ciência e Agrotecnologia , 2013,
Abstract: Seed marks the beginning of grain production from cultivated crops. Ensuring seed quality is the priority in the field of seed technology. In this context, the purpose of this study was to evaluate the use of carbon dioxide concentration to Classify Brassica napus seed lots of different quality resulting from various sowing dates. Seed lots were evaluated by percentage of normal plantlets and the germination rate index. CO2 concentration was quantified in samples submitted to five periods of incubation at 40° C with the aid of a gas exchange analyzer coupled to an injection and airflow system. The results were subjected to analysis of variance and the mean values were compared by the Duncan test and by regression analysis at the 5% level of significance. B. napus seeds from all lots showed a high percentage of normal plantlets and germination rate index. Percentage of normal plantlets was correlated with CO2 concentration. Determination of the CO2 concentration was more efficient with three hours of incubation which allowed classification of canola seed lots into four vigor classes. CO2 concentration was inversely proportional to the percentage of normal plantlets. A semente marca o inicio da produ o de gr os de plantas cultivadas. Assegurar a qualidade da semente é a prioridade da tecnologia de sementes. Neste contexto, o trabalho objetivou aferir o uso da concentra o de dióxido de carbono na classifica o de sementes de Brassica napus de diferentes níveis de qualidade resultante de diferentes datas de semeadura. nos quais avaliou-se a porcentagem de plantulas normais e o índice de velocidade de germina o. A concentra o CO2 foi quantificada em amostras mantidas por cinco períodos de incuba o a 40 °C e mensuradas com o auxílio de um medidor de trocas gasosas, acoplado a um sistema de inje o e fluxo de ar. Os resultados foram submetidos à análise de variancia e as médias comparadas pelo teste de Duncan e pela análise de regress o a 5%. Os resultados da porcentagem de plantulas normais foram correlacionados com os resultados da concentra o de CO2. Sementes de B. napus apresentaram alta porcentagem de plantulas normais. Contudo, para o índice de velocidade de germina o houve possibilidade de classifica o em pelo menos duas classes de vigor. A determina o da concentra o de CO2 foi mais eficiente após três horas de incuba o, sendo possível agrupar os lotes em quatro Classes de vigor. A concentra o de CO2 foi inversamente proporcional à porcentagem de plantulas normais, com melhor coeficiente de correla o obtido após três horas de incuba o.
Correla o entre dados estruturais e bandas de vibra o no infravermelho para a fase espinélio Zn7-xNixSb2O12
Gama L.,Vila C.,Campaneri R. L.,Paiva-Santos C. O.
Ceramica , 2000,
Abstract: A fase espinélio Zn7-xNi xSb2O12 tem apresentado propriedades magnéticas importantes, comportando-se como spin-glass. Desde que estas propriedades s o fortemente dependentes da configura o precisa dos átomos nesta estrutura, foram utilizados neste trabalho, com o intuito de clarificar essa configura o, a espectroscopia de infravermelho, aliada ao refinamento de estruturas pelo método de Rietveld. O espectro de infravermelho mostra nas condi es de contorno estudadas a presen a de três das quatro bandas ativas comuns aos espinélios. Conforme resultados do refinamento pelo método de Rietveld, o níquel substitui o zinco primeiramente no sítio octaédrico e, em altas concentra es (x > ou = 3), migra para o sítio tetraédrico. Essa migra o é indicada pelo "splitting", em torno de 520 cm-1, para (x > ou = 3), apresentado no espectro de infravermelho quando a banda n2 é afetada pela mudan a do cátion bivalente.
Um instrumento alternativo ao estudo de pilhas recarregáveis via Arduino
Luis Carlos Mathias,Osmar Henrique Moura da Silva,Paulo Rogério Catarini Silva
- , 2017, DOI: https://doi.org/10.5007/2175-7941.2017v34n1p310
Abstract: Recentes tecnologias tendem a invadir as escolas desencadeando modos diferenciados de se instruir conceitos científicos. Neste sentido, o presente trabalho emprega o dispositivo Arduino em uma inovadora montagem de um analisador de pilhas recarregáveis, que possibilita também uma proveitosa instru??o dos conceitos físico-químicos envolvidos. Este analisador realiza a carga e descarga de pilhas, viabilizando o cálculo da sua capacidade de carga e do seu estado de saúde, cujas reflex?es ent?o fornecidas subsidiam o educador interessado. Os resultados obtidos em uma avalia??o exemplar de três pilhas com diferentes capacidades de carga foram corroborados por um equipamento de laboratório de pesquisa em pilhas e baterias
Espectro Vibracional no Infravermelho Próximo dos Polímeros Poliestireno, Poli(Metacrilato de Metila) e Policarbonato
Araújo Sérgio C. de,Kawano Yoshio
Polímeros , 2001,
Abstract: Os espectros no infravermelho próximo (NIR) dos polímeros amorfos poliestireno (PS), poli(metacrilato de metila) (PMMA) e policarbonato (PC) foram estudados. A tentativa de atribui o das bandas harm nicas e de combina o dos modos vibracionais do PS, PMMA e PC foi realizada baseando-se na teoria de modos locais e pelo uso do método matemático de ajuste de curvas. A corre o de anarmonicidade e freqüência mecanica foi determinada em um gráfico de Birge-Sponer. Uma corre o de anarmonicidade de 57 e 58 cm-1 foi obtida para os modos de estiramento dos grupos CH2 e CH do PS; 59 e 9 cm-1 para os modos de estiramento dos grupos CH3 e CO do PMMA e 53, 59 e 10 cm-1 para os modos de estiramento dos grupos CH, CH3 e CO do PC, respectivamente.
O uso do analisador de anestésicos inalatórios como método de detec o de falha no aparelho de anestesia e preven o de consciência no per-operatório: relato de caso
Cruvinel Marcos Guilherme Cunha,Castro Carlos Henrique Viana de,Costa José Roberto de Rezende
Revista Brasileira de Anestesiologia , 2003,
Abstract: JUSTIFICATIVA E OBJETIVOS: A consciência per-operatória é uma rara, mas grave, complica o da anestesia geral. O mau funcionamento do aparelho de anestesia é uma das diversas causas das complica es anestésicas, dentre elas a consciência per-operatória. O objetivo deste relato é mostrar um caso em que o uso do analisador de anestésicos inalatórios proporcionou o diagnóstico de uma falha no aparelho de anestesia que poderia ter causado consciência no per-operatório. RELATO DO CASO: Paciente do sexo feminino, 38 anos, 55 kg, estado físico ASA I, portadora de carcinoma na mama direita, admitida para mastectomia radical e reconstru o mamária com retalho miocutaneo. Foi realizada pun o peridural em T8-T9 com agulha 17G com introdu o de cateter e administra o de ropivacaína a 0,2%. Seguiu-se indu o de anestesia geral com início de vaporiza o de sevoflurano. Apesar dos outros parametros de monitoriza o n o terem acusado achados de relevancia, o analisador de anestésicos inalatórios n o identificou a presen a de sevoflurano, o que conduziu ao diagnóstico de um vazamento no vaporizador. CONCLUS ES: A consciência per-operatória é uma complica o que, apesar de rara, é grave e deve ser prevenida. As falhas do equipamento de anestesia podem ser minimizadas por sua inspe o, com testes detalhados e rotineiros antes do seu uso. O analisador de anestésicos inalatórios é um monitor útil sempre que estes estejam sendo utilizados e um instrumento útil para detectar precocemente falhas no equipamento de anestesia, como exemplificado no caso relatado.
Development of infrared methodologies applied to determination of the metformin hidrochloride in pharmaceutical formulations Desenvolvimento de metodologias no infravermelho aplicadas para a quantifica o de cloridrato de metformina em formula es farmacêuticas
Graciele Parisotto,Marcelo Marques,Aline Lima Hermes,érico Marlon de Moraes Flores
Orbital : the Electronic Journal of Chemistry , 2008,
Abstract: In this work 20 metformin hydrochloride commercial pill samples and 14 synthetic samples were used and their spectra acquired in the 4000 – 650 cm-1 range by Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS). Multivariate calibration models were built and compared using all spectral region (global model PLS) and optimized models applying FTIR spectral sub-regions (iPLS and siPLS models). The best results were the ones obtained by using the siPLS algorithm, dividing the spectrum into 40 intervals and combining 3 intervals (37, 39 and 40) with 4 latent variables, which also presented an RMSEP value lower than the one obtained by using the global model and the iPLS algorithm. Finally, the application of selection techniques for infrared spectral regions (iPLS and siPLS) has been efficient to develop simpler, faster and non-destructive methodologies to analyze pharmaceutical pill formulations containing metformin, highlighting the potentialities of these techniques to control and inspect industrialized medicines. Neste trabalho 20 amostras comerciais sob a forma de comprimidos e 15 sintéticas de cloridrato de metformina foram utilizadas e seus espectros adquiridos na faixa de 4000–650 cm-1 por espectroscopia difusa no infravermelho com transformada de Fourier (DRIFTS). Foram construídos e comparados modelos de calibra o multivariada utilizando toda a regi o espectral analisada (modelo global PLS) e modelos otimizados empregando sub-regi es dos espectros FT-IR (modelos iPLS e siPLS). Os melhores resultados foram aqueles obtidos utilizando o algoritmo siPLS, dividindo o espectro em 40 intervalos e combinando 3 intervalos (37, 39 e 40), 4 variáveis latentes, e apresentou um valor de RMSEP inferior ao obtido utilizando o modelo global e o algoritmo iPLS. Assim, a aplica o das técnicas de sele o das regi es dos espectros de infravermelho (iPLS e siPLS) mostraram-se eficientes no desenvolvimento de metodologias mais simples, rápidas e n o destrutivas para a análise das formula es farmacêuticas contendo metformida na forma de comprimidos, destacando-se a potencialidade destas técnicas no controle e fiscaliza o de medicamentos industrializados.
Desenvolvimento de metodologias no infravermelho aplicadas para a quantifica o de cloridrato de metformina em formula es farmacêuticas
Graciele Parisotto,Marcelo Marques,Aline Lima Hermes,érico Marlon de Moraes Flores
Orbital : the Electronic Journal of Chemistry , 2009,
Abstract: Neste trabalho 20 amostras comerciais sob a forma de comprimidos e 15sintéticas de cloridrato de metformina foram utilizadas e seus espectros adquiridos na faixa de 4000–650 cm-1 por espectroscopia difusa no infravermelho com transformada de Fourier (DRIFTS). Foram construídos e comparados modelos de calibra o multivariada utilizando toda a regi o espectral analisada (modelo global PLS) e modelos otimizados empregando sub-regi es dos espectros FT-IR (modelos iPLS e siPLS). Os melhores resultados foram aqueles obtidos utilizando o algoritmo siPLS, dividindo o espectro em 40 intervalos e combinando 3 intervalos (37, 39 e 40), 4 variáveis latentes, e apresentou um valor de RMSEP inferior ao obtido utilizando o modelo global e o algoritmo iPLS. Assim, a aplica o das técnicas de sele o das regi es dos espectros de infravermelho (iPLS e siPLS) mostraram-se eficientes no desenvolvimento de metodologias mais simples, rápidas e n o destrutivas para a análise das formula es farmacêuticas contendo metformida na forma de comprimidos, destacando-se a potencialidade destas técnicas no controle e fiscaliza o de medicamentos industrializados.In this work 20 metformin hydrochloride commercial pill samples and 14 synthetic samples were used and their spectra acquired in the 4000 – 650 cm-1 range by Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS). Multivariate calibration models were built and compared using all spectral region (global model PLS) and optimized models applying FTIR spectral sub-regions (iPLS and siPLS models). The best results were the ones obtained by using the siPLS algorithm, dividing the spectrum into 40 intervals and combining 3 intervals (37, 39 and 40) with 4 latent variables, which also presented an RMSEP value lower than the one obtained by using the global model and the iPLS algorithm. Finally, the application of selection techniques for infrared spectral regions (iPLS and siPLS) has been efficient to develop simpler, faster and non-destructive methodologies to analyze pharmaceutical pill formulations containing metformin, highlighting the potentialities of these techniques to control and inspect industrialized medicines.
AVALIA O DO DESEMPENHO DE ONDALETAS PARA A CONSTRU O DE MODELOS DE REGRESS O MULTIVARIADA EMPREGANDO DADOS DE ESPECTROSCOPIA NO INFRAVERMELHO
M. Werlang,M. Rizzi,E. M. K. Theisen,G. Fenner
Tecno-Lógica , 2008,
Abstract: Neste trabalho utilizou-se a Transformada Discreta Ondaleta (TDO) Daubechies, com 4 coeficientes (Daub4), para compactar adimens o da matriz de dados espectrais, obtidos por espectroscopia no infravermelho com transformada de Fourier no intervalo 650-4.000 cm-1, através da reflectancia total atenuada (FTIR-ATR) de amostras de polióis de óleo de soja, visando a determina o do valorde hidroxilas (VOH) que para as amostras estudadas corresponde a faixa 23,66-195,04 mg de KOH/g. Através dos modelos deregress o por mínimos quadrados parciais (PLS), comparou-se o desempenho de cada um dos 5 conjuntos de dados compactados, como original e/ou entre eles. O conjunto de dados dos espectros de polióis, compactado a 1/4 da sua dimens o original, foi consideradocomo o mais robusto apresentando redu o do RMSEP em 20,28% em rela o ao modelo com os espectros n o compactados ecoeficientes de determina o semelhantes. Esse resultado implicou em um modelo de dimens es menores com a mesma capacidadepreditiva, assim a TDO (Daub4), mostra ser um método robusto para a redu o da dimens o da matriz de dados espectrais, quandopretende-se construir modelos de regress o multivariados.
Determina o em linha de tamanho de partículas na polimeriza o em suspens o
Santos Alexandre F.,Lima Enrique L.,Pinto José Carlos
Polímeros , 1999,
Abstract: A técnica de espectrofotometria na regi o do infra-vermelho próximo (NIR) é usada nesse trabalho para avaliar e controlar de forma contínua e em linha a evolu o do tamanho médio de partícula em polimeriza es de estireno em suspens o. Os resultados obtidos mostram que os espectros de NIR s o sensíveis a modifica es das condi es de opera o, podendo dessa forma prover informa es sobre a evolu o dinamica da distribui o de tamanhos de partícula e sobre a estabilidade da suspens o durante a polimeriza o. Observa-se que a manipula o das variáveis normalmente utilizadas para modificar as curvas de distribui o de tamanhos, tais como a velocidade de agita o e a concentra o de agente estabilizante, n o causa modifica es significativas na cinética da polimeriza o. Finalmente, experimentos mostram que a monitora o e controle contínuo da polimeriza o com a técnica de NIR permite projetar e obter distribui es de tamanho com valores médios pré-especificados, o que aponta para potencial desenvovlvimento de aplica es industriais.
Fotopolimeriza o: princípios e métodos
Rodrigues Máira R.,Neumann Miguel G.
Polímeros , 2003,
Abstract: O interesse na Fotoquímica de Polímeros tem crescido nas últimas décadas devido n o somente ao grande número de novas aplica es como também à repercuss o do ponto de vista econ mico, técnico e ecológico. A fotopolimeriza o/fotocura tem recebido a aten o especial devido às incontáveis aplica es e a sua importancia na área de Materiais. A cinética destes processos necessita de métodos analíticos precisos e rápidos para ser avaliada. Entre os métodos analíticos convencionais, os mais usados s o a gravimetria e a medida de propriedades macroscópicas, como resistência à tra o, à deforma o e dureza. Entretanto, para determina es mais analíticas é conveniente usar métodos que permitam estudar a cinética de fotopolimeriza o em tempo real. Neste sentido têm sido usadas técnicas como dilatometria, espectroscopia Raman, calorimetria, e espectroscopia de infravermelho por transformada de Fourier em tempo real. A atividade no campo da polimeriza o continua a se expandir em muitas áreas e, recentemente, o interesse nos sistemas do fotoinicia o envolvendo a polimeriza o via radicais livres, iniciada por luz visível, tem recebido aten o especial. Recentemente, estudos sobre fotopolimeriza o cati nica induzida pela luz visível come aram a ser pesquisados novamente devido à grande variedade de mon meros que s o polimerizáveis por via cati nica mas n o por via radicar, como, por exemplo, oxiranas e éteres vinílicos.
第1页/共1000条
每页显示 条


Home
Copyright © 2008-2020 Open Access Library. All rights reserved.