Voltage Stability and Power Flow Assessment of Industrial Load Integration under 12 MW PV Injection in Congo’s Grid

DOI: 10.4236/jpee.2026.1411003, PP. 30-51

Keywords: Photovoltaic Integration, Voltage Stability, Power Flow, Industrial Load, Weak Grid, Static Var Generator, Continuation Power Flow, Reactive-Power Compensation

Full-Text   Cite this paper   Add to My Lib

Abstract:

The integration of utility-scale photovoltaic generation into weak power systems can significantly affect power-flow distribution and voltage-stability margins, particularly when supplying reactive industrial loads. This paper investigates a 12 MW grid-connected photovoltaic plant supplying a 22 MVA industrial load under weak-grid conditions. The proposed assessment combines Newton-Raphson power flow, continuation-based P-V analysis, Jacobian minimum singular-value monitoring, and static var generator (SVG) compensation. For the adopted reduced benchmark with a short-circuit ratio of SCR = 5, the uncompensated system exhibits severe voltage degradation and limited loadability. A 6 MVAr SVG increases the minimum bus voltage from 0.617 to 0.855 p.u. and the maximum loading factor from 0.023 to 0.316. The corresponding maximum industrial active load increases from 19.13 to 24.61 MW, while active-power losses decrease from 0.924 to 0.210 MW. However, the compensated voltage remains below the 0.95 p.u. criterion, indicating that nominal reactive-power compensation alone does not ensure adequate voltage performance in a weak grid. The results highlight the need for SVG sizing based jointly on voltage regulation and static loadability constraints. Here, λ is the fractional load increase, with λ = 0 at nominal demand. The reported results require verification using the complete network dataset and actual SVG control settings.

References

[1]  Saleem, M.I., Saha, S., Izhar, U. and Ang, L. (2024) Stability Assessment of Inverter‐based Renewable Energy Sources Integrated to Weak Grids. IET Energy Systems Integration, 6, 525-544.
https://doi.org/10.1049/esi2.12151
[2]  Sanni, S.O., Abdullateef, A.I., Mohammed, O.O., Aman, M.N., Raji, A.K. and Fajuke, I.D. (2024) Investigating the Impact of Solar PV and Wind Energy Systems on the Strength of a Longitudinal Power Grid. e-Prime—Advances in Electrical Engineering, Electronics and Energy, 8, Article 100593.
https://doi.org/10.1016/j.prime.2024.100593
[3]  Zhang, Q., Hu, Q., Sun, S., Mei, D., Liu, S. and Liu, X. (2023) Voltage and Frequency Instability in Large PV Systems Connected to Weak Power Grid. Frontiers in Energy Research, 11, Article 1210514.
https://doi.org/10.3389/fenrg.2023.1210514
[4]  Lei, P. and Zhao, J. (2024) The Analysis of the Threshold Value of the Complex Short-Circuit Ratio Index and Its Significance in the Context of Static Voltage Stability. Frontiers in Energy Research, 12, Article 1413910.
https://doi.org/10.3389/fenrg.2024.1413910
[5]  Yu, L., Xu, S., Sun, H., Zhao, B., Wu, G. and Zhou, X. (2024) Multiple Renewable Short-Circuit Ratio for Assessing Weak System Strength with Inverter-Based Resources. CSEE Journal of Power and Energy Systems, 10, 2271-2282.
[6]  Miyazaki, M., Aoki, M. and Nakamura, Y. (2025) Voltage Stability Estimation Considering Variability in Reactive Power Reserves Using Regression Trees. Energies, 18, Article No. 1260.
https://doi.org/10.3390/en18051260
[7]  Yenealem, M.G. (2025) Voltage Stability Assessment and Improvement of Ethiopian 230 kV Wind-Integrated Grid Using SVC and Continuation Power Flow in PSAT. Scientific Reports, 15, Article No. 31946.
https://doi.org/10.1038/s41598-025-13206-w
[8]  Adetona, S., Balogun, A., Esenwa, E., Olajube, A., Awelewa, A. and Okafor, F. (2024) A Model Predictive Control-Based STATCOM for Weak Grid Voltage Enhancement. Engineering and Technology Journal, 42, 1138-1154.
https://doi.org/10.30684/etj.2024.149900.1752
[9]  Cao, J., Liu, M., Ma, Q., Fan, J., Song, D., Zhou, X., et al. (2025) Assessment of Grid-Tied Renewable Energy Systems’ Voltage Support Capability under Various Reactive Power Compensation Devices. Energies, 18, Article No. 3880.
https://doi.org/10.3390/en18143880
[10]  Zhang, S., Chen, Y., Li, Q., Xie, Z., Fu, Y. and Wu, W. (2025) Quantitative Stability Analysis of STATCOM in Voltage Control Mode and Enhanced Control Method Based on Voltage Feedforward. International Journal of Electrical Power & Energy Systems, 171, Article 110975.
https://doi.org/10.1016/j.ijepes.2025.110975
[11]  Liu, J., Wang, L., Jiao, T., Yang, W., Xu, R., Wu, K., et al. (2024) Multi-Period Voltage Stability-Constrained Optimal Power Flow with Uncertainties. Applied Energy, 369, Article 123522.
https://doi.org/10.1016/j.apenergy.2024.123522
[12]  Kim, H., Woo, H., Yoon, Y., Kim, H., Kim, Y.J., Kang, M., et al. (2024) An Enhanced Continuation Power Flow Method Using Hybrid Parameterization. Sustainability, 16, Article 7595.
https://doi.org/10.3390/su16177595
[13]  Wang, T., Wang, S., Ma, S., Guo, J. and Zhou, X. (2024) An Extended Continuation Power Flow Method for Static Voltage Stability Assessment of Renewable Power Generation-Penetrated Power Systems. IEEE Transactions on Circuits and Systems II: Express Briefs, 71, 892-896.
https://doi.org/10.1109/tcsii.2022.3209335
[14]  Suresh, A., Hasan, M.S., Kamalasadan, S. and Paudyal, S. (2025) A Distributed Energy Resources Integrated Transmission and Distribution Continuation Power Flow Model with Sequence Component Approach. IEEE Transactions on Industry Applications, 61, 5637-5648.
https://doi.org/10.1109/tia.2025.3544982
[15]  Al-Majali, B.H. and Zobaa, A.F. (2025) A Novel Optimal Allocation of STATCOM to Enhance Voltage Stability in Power Networks. Ain Shams Engineering Journal, 15, Article 102658.
https://doi.org/10.1016/j.asej.2024.102658