This study examines an evolving disturbance on the T100B feeder at the Lamadji 90/15 kV substation using relay-display screenshots and previously tabulated NEPLAN short-circuit results. Visual inspection suggests an initial phase-A-to-ground fault, followed by an A-C-to-ground stage and a three-phase stage, with recurrence after an apparent reclosing operation. This chronology is provisional: raw COMTRADE samples, verified CT/VT ratios, and breaker-status records were not supplied. Reported peak currents of 1.5 and 5 kA give approximate RMS estimates of 1.06 and 3.54 kA only under a sinusoidal assumption. The closest three-phase current among six tested nodes is 3.83 kA at JDB15, with an 8.19% discrepancy using the rounded RMS estimate. At that assumed location, the tested A-G resistance of 7 Ω produces 1.072 kA, with a 1.13% discrepancy. These are amplitude agreements used for case selection, not independent validation. The proposed signal-processing and classification equations are retained as an unevaluated framework. The available scalar currents cannot uniquely separate fault resistance from distance, establish the feeder measurement equivalent of a busbar fault, or explain the reported general outage. The study therefore reports a conditional resistance candidate and specifies the data needed for quantitative validation.
References
[1]
Peng, N., Zhang, Z., Liang, R., Jiang, C., Zhang, P., Ren, X., et al. (2023) Fault Sensing of the Distribution Cable Feeders by Time-Domain Measurements. IEEE Transactions on Industrial Informatics, 19, 8170-8182. https://doi.org/10.1109/tii.2022.3217276
[2]
Jiang, Y. (2021) Data-Driven Probabilistic Fault Location of Electric Power Distribution Systems Incorporating Data Uncertainties. IEEE Transactions on Smart Grid, 12, 4522-4534. https://doi.org/10.1109/tsg.2021.3070550
[3]
Rios Penaloza, J.D., Borghetti, A., Napolitano, F., Tossani, F. and Nucci, C.A. (2021) Performance Analysis of a Transient-Based Earth Fault Protection System for Unearthed and Compensated Radial Distribution Networks. Electric Power Systems Research, 197, Article ID: 107306. https://doi.org/10.1016/j.epsr.2021.107306
[4]
Yu, K., Yu, Q., Zeng, X., Zeng, J., Ni, Y., Zou, H., et al. (2022) A Novel Method of High Impedance Fault Detection and Fault Resistance Calculation Based on Damping Rate Double-Ended Measurement for Distribution Network. International Journal of Electrical Power & Energy Systems, 136, Article ID: 107686. https://doi.org/10.1016/j.ijepes.2021.107686
[5]
Arsoniadis, C.G., Apostolopoulos, C.A., Georgilakis, P.S. and Nikolaidis, V.C. (2021) A Voltage-Based Fault Location Algorithm for Medium Voltage Active Distribution Systems. Electric Power Systems Research, 196, Article ID: 107236. https://doi.org/10.1016/j.epsr.2021.107236
[6]
International Electrotechnical Commission (2026) Short-Circuit Currents in Three-Phase AC Systems—Part 0: Calculation of Currents, IEC 60909-0:2026, 3rd Edition. https://webstore.iec.ch/en/publication/68454
[7]
International Electrotechnical Commission (2021) Short-Circuit Currents in Three-Phase AC Systems—Part 4: Examples for the Calculation of Short-Circuit Currents, IEC TR 60909-4:2021, 2nd Edition. https://webstore.iec.ch/en/publication/66482
[8]
IEEE/IEC (2013) Measuring Relays and Protection Equipment—Part 24: Common Format for Transient Data Exchange (COMTRADE) for Power Systems, IEEE C37.111-2013/IEC 60255-24:2013. https://webstore.iec.ch/en/publication/1170
[9]
IEC (2016) Short-Circuit Currents in Three-Phase AC Systems—Part 0: Calculation of Currents, IEC 60909-0:2016, 2nd Edition. https://webstore.iec.ch/en/publication/24100
[10]
Schneider Electric (2023) Easergy MiCOM P141/P142/P143/P145 Feeder Management Relay, SW Version B6, Technical Manual P14x/EN M/On8, Version 1.0, 11. https://www.se.com/us/en/download/document/P14x_EN_M_On8__B6__LM/