Background: Cerclage wires are commonly used for fixation of the greater trochanter during total hip arthroplasty (THA). Breakage of the fixation material is a recognized complication, but distant migration of a broken fragment is rare. Case Presentation: An 83-year-old woman underwent primary THA with a double-mobility prosthesis for an intertrochanteric fracture associated with symptomatic hip osteoarthritis; the greater trochanter was fixed with a trochanteric claw plate and four metallic cerclage wire loops. She remained asymptomatic for three years and then presented with abdominal pain and diarrhea. Plain radiographs showed a broken segment of one cerclage wire projecting over the right iliac fossa, whereas the remaining construct and the arthroplasty components were stable and the trochanter was united. At surgical exploration of an abdominal wall eventration, the fragment was found contained within the abdominal wall, without peritoneal breach or visceral injury. It was removed and the abdominal wall was repaired with mesh. Symptoms resolved within a few days, and at six months there were no complications and hip function was normal. Conclusion: A broken trochanteric cerclage wire fragment can migrate far from the greater trochanter years after THA and present with abdominal rather than hip symptoms. In patients with prior trochanteric wiring and unexplained abdominal complaints, pelvic radiographs should be reviewed, and cross-sectional imaging is advisable to define the relationship of a migrated fragment to the viscera and vessels before removal.
References
[1]
Jarit, G.J., Sathappan, S.S., Panchal, A., Strauss, E. and Di Cesare, P.E. (2007) Fixation Systems of Greater Trochanteric Osteotomies: Biomechanical and Clinical Outcomes. Journal of the American Academy of Orthopaedic Surgeons, 15, 614-624. https://doi.org/10.5435/00124635-200710000-00006
[2]
Berton, C., Puskas, G.J., Christofilopoulos, P., Stern, R., Hoffmeyer, P. and Lübbeke, A. (2012) Comparison of the Outcome Following the Fixation of Osteotomies or Fractures Associated with Total Hip Replacement Using Cables or Wires. The Journal of Bone and Joint Surgery. British Volume, 94, 1475-1481. https://doi.org/10.1302/0301-620x.94b11.29687
[3]
Schafer, P., Sullivan, T.C., Lambert, B., Park, K.J., Clyburn, T.A. and Incavo, S.J. (2023) Greater Trochanteric Fixation Using Cable Plate Devices in Complex Primary and Revision Total Hip Arthroplasty. Arthroplasty Today, 20, Article ID: 101103. https://doi.org/10.1016/j.artd.2023.101103
[4]
Karaismailoglu, B. and Karaismailoglu, T.N. (2018) Medial Migration of a Broken Trochanteric Cable. Case Reports in Orthopedics, 2018, Article ID: 4590105. https://doi.org/10.1155/2018/4590105
[5]
Kollitz, K.M., Dale, J. and Richardson, M.L. (2014) Migration of Trochanteric Cerclage Cable Debris to the Knee Joint. Radiology Case Reports, 9, Article 955. https://doi.org/10.2484/rcr.v9i3.955
[6]
Kotela, A., Lorkowski, J., Chmielewski, D., Grodzik, M. and Kotela, I. (2020) Revision Hip Arthroplasty in Patient with Acetabulum Migration into Subperitoneal Space—A Case Report. Medicina, 57, Article 30. https://doi.org/10.3390/medicina57010030
[7]
Kuroshima, K., Kasahara, K., Kihara, S., Harada, Y. and Sumi, M. (2021) Medial Pelvic Migration of the Lag Screw after Intramedullary Nailing for Trochanteric Femoral Fracture. Case Reports in Orthopedics, 2021, Article ID: 5553835. https://doi.org/10.1155/2021/5553835
[8]
Jones, E., Khan, M., Samones, E.J. and Savino, P.B. (2026) Case Report of Orthopedic Screw Migration Presenting as Abdominal Pain in the Emergency Department. Clinical Practice and Cases in Emergency Medicine. https://doi.org/10.5811/cpcem.50761
[9]
Gouin, F., Crenn, V. and Tabutin, J. (2017) Subperitoneal Approach in Revision Arthroplasty for Acetabular Component Protrusion: Analysis of Practices within the French Hip and Knee Society (SFHG). Orthopaedics & Traumatology: Surgery & Research, 103, 27-31. https://doi.org/10.1016/j.otsr.2016.10.005