基于有限差分法的烟气–熔盐储热系统运行模式转换的瞬态分析
Transient Analysis of Operational Modes for Flue Gas-Molten Salt Heat Storage System Based on the Finite Difference Method

DOI: 10.12677/se.2026.164009, PP. 93-108

Keywords: 烟气–熔盐换热器,有限差分法,熔盐储热,动态仿真
Flue Gas-Molten Salt Heat Exchanger
, Finite Difference Method, Molten Salt Thermal Storage, Dynamic Simulation

Full-Text   Cite this paper   Add to My Lib

Abstract:

本文基于有限差分法建立瞬态仿真模型,分析了世界首台烟气–熔盐储热系统的稳态与瞬态特性。在额定工况下,烟气出口、熔盐出口和换热管束的平均稳态温度分别为301.46℃、388.82℃和317.05℃。采用额定烟气流量,启动预热至目标温度,储热启动需要279.9秒,伴热启动需要812.6秒。退出过程中,冷却至200℃所需时间:储热退出为59.8小时,伴热退出为101.3小时;进一步冷却至25℃则分别需要588.8小时和736.0小时。本文为该类系统的设计与运行提供了理论与实践指导。
This paper develops a transient simulation model based on the finite difference method to analyze the steady-state and transient characteristics of the world first flue gas–molten salt thermal storage system. At rated conditions, steady-state temperatures are 301.46?C, 388.82?C, and 317.05?C for the flue gas outlet, molten salt outlet, and average heat exchange tubes bundle, respectively. Using the rated flue gas flow, startup preheating to the target temperatures requires 279.9 s for thermal storage and 812.6 s for thermal preservation. During shutdown, cooling to 200?C takes 59.8 h (thermal storage) and 101.3 h (thermal preservation); cooling further to 25?C requires 588.8 h and 736.0 h, respectively. This work provides theoretical and practical guidance for the design and operation of such systems.

References

[1]  Lei, Y., Wang, Z., Wang, D., Zhang, X., Che, H., Yue, X., et al. (2023) Co-Benefits of Carbon Neutrality in Enhancing and Stabilizing Solar and Wind Energy. Nature Climate Change, 13, 693-700.
https://doi.org/10.1038/s41558-023-01692-7
[2]  Li, C., Shah, N., Li, Z. and Liu, P. (2024) Modelling of Wind and Solar Power Output Uncertainty in Power Systems Based on Historical Data: A Characterisation through Deterministic Parameters. Journal of Cleaner Production, 484, Article ID: 144233.
https://doi.org/10.1016/j.jclepro.2024.144233
[3]  Hu, X.N., Deng, B.Y., Liu, H.P., et al. (2023) Status and Development Trend of Rapid Load Regulation Technology for Circulating Fluidized Bed Boiler. Clean Coal Technology, 29, 11-23. (In Chinese)
[4]  Zhang, Y.H., Song, X.H., Yang, R.G. and Li, X.B. (2024) Performance of Molten Salt Thermal Energy Storage System Based on Reheat Steam Extraction from Coal-Fired Power Plants. Journal of Chinese Society of Power Engineering, 44, 447-454. (In Chinese)
[5]  Liu, T., Xiao, X., Long, Y., Li, Y. and Tang, R. (2025) Performance Analysis of a Cogeneration System Coupled with Molten Salt Heat Storage. Applied Thermal Engineering, 281, Article ID: 128736.
https://doi.org/10.1016/j.applthermaleng.2025.128736
[6]  Krüger, M., Muslubas, S., Çam, E., Lehmann, D., Polenz, S., Dreißigacker, V., et al. (2022) Technical Development and Economic Evaluation of the Integration of Thermal Energy Storage in Steam Power Plants. Energies, 15, Article 3388.
https://doi.org/10.3390/en15093388
[7]  Su, H., Xu, J., Yu, X., Dong, X., Liu, C., Wang, Y., et al. (2025) Experimental Study on Flow and Heat Transfer of a Novel Molten-Salt-Heat-Exchanger for Flue Gas Energy Storage. Journal of Energy Storage, 132, Article ID: 117961.
https://doi.org/10.1016/j.est.2025.117961
[8]  Mu, Z., Jiang, K., Zhang, Q., Wang, Q., Niu, Y. and Liu, J. (2024) Dynamic Characteristics and Real-Time Control of Flue Gas-Molten Salt Heat Exchanger for Flexibility Transformation of Coal-Fired Power Plants. Applied Thermal Engineering, 257, Article ID: 124319.
https://doi.org/10.1016/j.applthermaleng.2024.124319
[9]  Guo, W., Liu, C., Xu, J., Chen, Z., Yu, X., Dong, X., et al. (2025) Numerical Analysis of the Steady and Transient Operating Characteristics of the Flue Gas Molten Salt Heat Storage System. Applied Thermal Engineering, 271, Article ID: 126279.
https://doi.org/10.1016/j.applthermaleng.2025.126279
[10]  Utz, T., Meurer, T. and Kugi, A. (2007) Motion Planning for the Heat Equation with Radiation Boundary Conditions Based on Finite Difference Semi-Discretizations. IFAC Proceedings Volumes, 40, 306-311.
https://doi.org/10.3182/20070822-3-za-2920.00051
[11]  Lin, Z. and Xu, T. (2022) Utility Boiler Handbook. Chemical Industry Press Co., Ltd. (In Chinese)
[12]  Wu, Y., Chen, C., Liu, B. and Ma, C. (2012) Investigation on Forced Convective Heat Transfer of Molten Salts in Circular Tubes. International Communications in Heat and Mass Transfer, 39, 1550-1555.
https://doi.org/10.1016/j.icheatmasstransfer.2012.09.002
[13]  Buttsworth, D.R. (2001) A Finite Difference Routine for the Solution of Transient One Dimensional Heat Conduction Problems with Curvature and Varying Thermal Properties. University of Southern Queensland.
[14]  Churchill, S.W. and Chu, H.H.S. (1975) Correlating Equations for Laminar and Turbulent Free Convection from a Vertical Plate. International Journal of Heat and Mass Transfer, 18, 1323-1329.
https://doi.org/10.1016/0017-9310(75)90243-4