Wear Performance of Materials Used in Artificial Hip Joints
—1. THR Diameter/Wear Ratios in Artificial Hip Joints: A 63-Year Charnley Legacy

DOI: 10.4236/ojo.2026.167036, PP. 385-411

Keywords: Total Hip Replacement (THR), Wear, Teflon, Ultra-High Molecular Weight Polyethylene (UHMWPE), Simulator Wear Dichotomy (SWD), Femoral Head Diameter, In Vitro Wear Simulation, Charnley Hip Arthroplasty

Full-Text   Cite this paper   Add to My Lib

Abstract:

Following the 1956 introduction of polytetrafluoroethylene (PTFE) total hip replacements (THR), a concerning question was how much wear debris could periarticular tissues tolerate before onset of adverse reactions. John Charnley’s historical studies demonstrated that wear in PTFE (“Teflon”) bearings led to destructive hip lesions within 3 years. While smaller femoral heads somewhat reduced wear, Teflon debris remained intolerable. In 1962 Charnley’s laboratory identified polyethylene (UHMWPE) as a substantially more wear-resistant polymer, launching the Charnley low-friction arthroplasty (LFA) in 1962. Three important results were clear: 1) femoral head diameter is the major wear determinant, i.e. the Charnley Diameter-Wear effect (“CDW”), 2) laboratory studies demonstrated UHMWPE had superior wear resistance to PTFE, and 3) major differences existed between laboratory predictions and clinical wear data, a phenomenon we shall term Laboratory Wear Divergence (“LWD”). This review examines wear data published by four laboratories to evaluate reproducibility, accuracy, and relevance of historical wear studies (1956-1976). Charnley’s wear laboratory described Teflon:UHMWPE wear ratios ranging 200:1 to 500:1 (1969). The introduction of UCLA’s wear machine in 1978 provided a dramatic improvement in experimental procedures. Using gravimetric weight-loss measurements in bovine-serum lubricated studies, the UCLA method for 316SS:UHMWPE samples achieved a wear precision of 0.2 mm3/Mc (±15%). Despite this precision, the LWD wear ratio (1600:1) for PTFE:UHMWPE wear greatly exceeded Charnley’s clinical (16:1) and laboratory (200:1) ratios. Orthopedic Hospital of Los Angeles (OHLA) reported (1981) a simulator design that incorporated multi-directional motion using crossing-path wear (CPW) motion. The pilot PTFE study (28 mm THR) yielded exceptionally high wear (2100 mm3/Mc), representing a debris release of 180 mm3 per 24-hours and prompted termination of study. This PTFE simulator wear overshot the clinical 28 mm Teflon wear (1171 mm3/year), a ratio of 1.8:1. This PTFE:Teflon wear (laboratory vs clinical) will be designated “WRP”. Kinamed (1996) investigated the Charnley-diameter-wear effect (CDW) using Al2O3: UHMWPE THR (22.25, 26, 28 mm dia.). Assuming Charnley’s clinical report is typical of LFA (60 mm3/year), the UHMWPE simulator ratio PCR = 0.6:1, i.e. it undershot the clinical UHMWPE datum. The 32.8 mm3/Mc wear rate (28 mm THR) corresponded to a CDW ratio of

References

[1]  Amstutz, H.C. and Clarke, I.C. (1991) Evolution of Hip Arthroplasty. In: Amstutz, H.C., Ed., Hip Arthroplasty, Churchill Livingstone, Inc., 1-14.
[2]  Metcalfe, R.G. and Porter, M. (2024) John Charnley’s Assistant: Harry Craven and the Charnley Hip. Biomedical Materials & Devices, 2, 1156-1174.
https://doi.org/10.1007/s44174-024-00157-5
[3]  Charnley, J., Kamangar, A. and Longfield, M.D. (1969) The Optimum Size of Prosthetic Heads in Relation to the Wear of Plastic Sockets in Total Replacement of the Hip. Medical & Biological Engineering, 7, 31-39.
https://doi.org/10.1007/bf02474667
[4]  Charnley, J. (1974) The Status of Research into the Wear of High Molecular Weight Polyethylene in Total Hip Replacements as of January 1974. Internal Publication No. 49, Center for Hip Surgery, Wrightington Hospital.
[5]  Duff-Barclay, I. and Spillman, D.T. (1966) Total Human Hip Joint Prostheses—A Laboratory Study of Friction and Wear. Proceedings of the Institution of Mechanical Engineers.
[6]  McKellop, H., Clarke, I.C., Markolf, K.L. and Amstutz, H.C. (1978) Wear Characteristics of UHMW Polyethylene: A Method for Accurately Measuring Extremely Low Wear Rates. Journal of Biomedical Materials Research, 12, 895-927.
https://doi.org/10.1002/jbm.820120611
[7]  McKellop, H., Clarke, I., Markolf, K. and Amstutz, H. (1981) Friction and Wear Properties of Polymer, Metal, and Ceramic Prosthetic Joint Materials Evaluated on a Multichannel Screening Device. Journal of Biomedical Materials Research, 15, 619-653.
https://doi.org/10.1002/jbm.820150503
[8]  Clarke, I.C. (1981) Wear of Artificial Joint Materials IV. Hip Joint Simulator Studies. Engineering in Medicine, 10, 189-198.
https://doi.org/10.1243/emed_jour_1981_010_052_02
[9]  Clarke, I.C. (1981) Wear of Artificial Joint Materials I. Friction and Wear Studies. Engineering in Medicine, 10, 115-122.
https://doi.org/10.1243/emed_jour_1981_010_036_02
[10]  Swanson, A. (1977) Limitations of Joint Simulators. In: Wright, V. and Dowson, D., Eds., Evaluation of Artificial Joints, The Biological Engineering Society, 37-46.
[11]  Dumbleton, J.H. (1977) Joint Simulators. Limitations of Joint Simulators. In: Evaluation of Artificial Joints, 47-49.
[12]  Seedhom, B.B., Dowson, D. and Wright, V. (1973) Wear of Solid Phase Formed High Density Polyethylene in Relation to the Life of Artificial Hips and Knees. Wear, 24, 35-51.
https://doi.org/10.1016/0043-1648(73)90201-9
[13]  Charnley, J. (1975) The Wear of Materials in the in the Hip Joint. In: Plastics in Medicine and Surgery, Plastics and Rubber Institute, 3.1-3.10.
[14]  Clarke, I.C. and McKellop, H. (1986) Wear Testing. In: von Recum, A.F., Ed., Handbook of Biomaterials Evaluation: Scientific, Technical, and Clinical Testing of Implant Materials, Macmillan.
[15]  Clarke, I.C. (1981) Wear of Polymeric Prosthesis—Clinical Reality, Retrieved Implants and Laboratory Predicaitons. In: Weinstein, A., et al., Eds., Implant Retrieval: Material and Biological Analysis, National Bureau of Standards, 471-497.
[16]  Clarke, I.C. and Kabo, J.M. (1991) Wear in Total Hip Replacement. In: Amstutz, H.C., Ed., Hip Arthroplasty, Churchill Livingstone, 535-553.
[17]  Clarke, I., McKellop, H., McGuire, P., Okuda, R. and Sarmiento, A. (1983) Wear of Ti-6A1-4V Implant Alloy and Ultrahigh Molecular Weight Polyethylene Combinations. In: Luckey, H.A. and Kubli Jr., F., Eds., Titanium Alloys in Surgical Implants, ASTM International, 136-147.
https://doi.org/10.1520/stp28940s
[18]  McKellop, H.A. and R?stlund, T.V. (1990) The Wear Behavior of Ion-Implanted Ti‐6Al-4V against UHMW Polyethylene. Journal of Biomedical Materials Research, 24, 1413-1425.
https://doi.org/10.1002/jbm.820241102
[19]  Clarke, I.C., Good, V., Anissian, L. and Gustafson, A. (1997) Charnley Wear Model for Validation of Hip Simulators’ Ball Diameter versus Polytetrafluoroethylene and Polyethylene Wear. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 211, 25-36.
https://doi.org/10.1243/0954411971534656
[20]  McKellop, H. (1981) Wear of Artificial Joint Materials II. Engineering in Medicine, 10, 123-136.
https://doi.org/10.1243/emed_jour_1981_010_037_02
[21]  ASTM F732 (2011) Standard Test Method for Wear Testing of Polymeric Materials Used in Total Joint Prostheses.
[22]  ISO 14242-3 (2008) Implants for Surgery—Wear of Total Hip Joint Prostheses—Part 3: Loading and Displacement Parameters for Orbital Bearing Type Wear Testing Machines and Corresponding Environmental Conditions for Test.
[23]  Clarke, I.C., Gustafson, A., Jung, H. and Fujisawa, A. (1996) Hip-Simulator Ranking of Polyethylene Wear: Comparisons between Ceramic Heads of Different Sizes. Acta Orthopaedica Scandinavica, 67, 128-132.
https://doi.org/10.3109/17453679608994656
[24]  Paul, J.P. (1966) Biomechanics. The Biomechanics of the Hip-Joint and Its Clinical Relevance. Proceedings of the Royal Society of Medicine, 59, 943-948.
https://doi.org/10.1177/003591576605901009
[25]  Pappas, M.J., Makris, G. and Buechel, F.F. (1995) Titanium Nitride Ceramic Film against Polyethylene. A 48 Million Cycle Wear Test. Clinical Orthopaedics & Related Research, 317, 64-70.
[26]  Saikko, V.O. (1995) Wear of the Polyethylene Acetabular Cup: The Effect of Head Material, Head Diameter, and Cup Thickness Studied with a Hip Simulator. Acta Orthopaedica Scandinavica, 66, 501-506.
https://doi.org/10.3109/17453679509002302

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133