全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Audiological Outcomes of Different Cochlear Implant Electrodes in Congenitally Deaf Children: A Prospective Observational Study

DOI: 10.4236/ijohns.2026.154023, PP. 249-260

Keywords: Cochlear Implants, Electrodes, Profound Hearing Loss, Hearing Outcomes

Full-Text   Cite this paper   Add to My Lib

Abstract:

Objective: To evaluate short-term audiological outcomes in congenitally deaf pediatric patients implanted with lateral wall or perimodiolar cochlear implant electrode arrays. Study design: Prospective observational study. Methods: The study included children with bilateral congenital profound sensorineural hearing loss who underwent unilateral cochlear implantation between January 2022 and January 2023 at two tertiary referral centers. Audiological outcomes, including free field pure tone average (PTA) and word discrimination threshold (WDT), were assessed 6 months after initial device activation. Comparisons were performed according to electrode manufacturer and design. Results: A total of 259 patients (mean age 33.4 months) were analyzed. One hundred ninety-two patients received lateral wall electrodes and 67 received perimodiolar electrodes. The mean PTA was 33.01?dB HL for lateral wall arrays and 32.03 dB HL for perimodiolar arrays (p = 0.18). Mean WDT values were 64.22 dB HL and 62.72?dB HL, respectively (p = 0.25). No statistically significant differences were identified between electrode designs or among manufacturers. Conclusion: In the short term, lateral wall and perimodiolar cochlear implant electrode arrays provided comparable audiological outcomes in congenitally deaf pediatric patients.

References

[1]  O’Connell, B.P., Hunter, J.B. and Wanna, G.B. (2016) The Importance of Electrode Location in Cochlear Implantation. Laryngoscope Investigative Otolaryngology, 1, 169-174.
https://doi.org/10.1002/lio2.42
[2]  Mistrík, P., Jolly, C., Sieber, D. and Hochmair, I. (2017) Challenging Aspects of Contemporary Cochlear Implant Electrode Array Design. World Journal of Otorhinolaryngology—Head and Neck Surgery, 3, 192-199.
https://doi.org/10.1016/j.wjorl.2017.12.007
[3]  Perenyi, A., Toth, F., Dimak, B., Nagy, R., Schoerg, P., Jori, J., et al. (2019) Electrophysiological Measurements with Electrode Types of Different Perimodiolar Properties and the Same Cochlear Implant Electronics—A Retrospective Comparison Study. Journal of Otolaryngology—Head & Neck Surgery, 48, Article No. 46.
https://doi.org/10.1186/s40463-019-0361-8
[4]  Mady, L.J., Sukato, D.C., Fruit, J., Palmer, C., Raz, Y., Hirsch, B.E., et al. (2017) Hearing Preservation: Does Electrode Choice Matter? Otolaryngology—Head and Neck Surgery, 157, 837-847.
https://doi.org/10.1177/0194599817707167
[5]  Zhou, N., Shi, X., Dixit, O., Firszt, J.B. and Holden, T.A. (2023) Relationship between Electrode Position and Temporal Modulation Sensitivity in Cochlear Implant Users: Are Close Electrodes Always Better? Heliyon, 9, e12467.
https://doi.org/10.1016/j.heliyon.2022.e12467
[6]  Dhanasingh, A. (2022) Design of a Cochlear Implant Electrode. ENT Updates, 12, 97-109.
https://doi.org/10.5152/entupdates.2022.22213
[7]  Gibson, P. and Boyd, P. (2016) Optimal Electrode Design: Straight versus Perimodiolar. European Annals of Otorhinolaryngology, Head and Neck Diseases, 133, S63-S65.
https://doi.org/10.1016/j.anorl.2016.04.014
[8]  Rebscher, S.J., Hetherington, A., Bonham, B., Wardrop, P., Whinney, D. and Leake, P.A. (2008) Considerations for Design of Future Cochlear Implant Electrode Arrays: Electrode Array Stiffness, Size, and Depth of Insertion. The Journal of Rehabilitation Research and Development, 45, 731-748.
https://doi.org/10.1682/jrrd.2007.08.0119
[9]  Mekki, S., Quriba, A. and Gad, N. (2020) Value of Auditory Perception of Alphabet Letters Test (Arabic Standardized Version) in Evaluation of Arabic Speaking CI Children. Hearing Balance and Communication, 18, 116-121.
https://doi.org/10.1080/21695717.2019.1630977
[10]  Timm, M.E., Majdani, O., Weller, T., Windeler, M., Lenarz, T., Büchner, A., et al. (2018) Patient Specific Selection of Lateral Wall Cochlear Implant Electrodes Based on Anatomical Indication Ranges. PLOS ONE, 13, e0206435.
https://doi.org/10.1371/journal.pone.0206435
[11]  Esquia Medina, G.N., Borel, S., Nguyen, Y., Ambert-Dahan, E., Ferrary, E., Sterkers, O., et al. (2013) Is Electrode-Modiolus Distance a Prognostic Factor for Hearing Performances after Cochlear Implant Surgery? Audiology and Neurotology, 18, 406-413.
https://doi.org/10.1159/000354115
[12]  Jeong, J., Kim, M., Heo, J.H., Bang, M., Bae, M.R., Kim, J., et al. (2015) Intraindividual Comparison of Psychophysical Parameters between Perimodiolar and Lateral-Type Electrode Arrays in Patients with Bilateral Cochlear Implants. Otology & Neurotology, 36, 228-234.
https://doi.org/10.1097/mao.0000000000000672
[13]  Kim, J., Hong, S.H. and Moon, I.J. (2024) Association between Intracochlear Electrode Design and Electrically-Evoked Compound Action Potential Measures in Cochlear Implant Users. Otolaryngology—Head and Neck Surgery, 171, 849-857.
https://doi.org/10.1002/ohn.799
[14]  Patro, A., Lindquist, N.R., Schauwecker, N., Holder, J.T., Perkins, E.L., Haynes, D.S., et al. (2024) Comparison of Speech Recognition and Hearing Preservation Outcomes between the Mid-Scala and Lateral Wall Electrode Arrays. Otology & Neurotology, 45, 52-57.
https://doi.org/10.1097/mao.0000000000004064
[15]  Abdallah Mohamed Shoeib, S.A., Ibrahim, S.A., Sobhy, T.S. and Abdelmoneim Teaima, A. (2024) Comparison of the Outcome between Lateral, Perimodilar and Midscalar Electrodes in Cochlear Implantation Surgery: A Systematic Review. QJM: An International Journal of Medicine, 117, hcae175.243.
https://doi.org/10.1093/qjmed/hcae175.243
[16]  Duckett, K.A., Kassir, M.F., Munhall, C.C., Schvartz-Leyzac, K.C., Nguyen, S.A. and Labadie, R.F. (2025) Does Cochlear Implant Electrode Array Design Affect Audiologic Outcomes? A Systematic Review and Meta-Analysis. Acta Oto-Laryngologica, 146, 159-175.
https://doi.org/10.1080/00016489.2025.2451074
[17]  van der Marel, K.S., Briaire, J.J., Verbist, B.M., Muurling, T.J. and Frijns, J.H.M. (2015) The Influence of Cochlear Implant Electrode Position on Performance. Audiology and Neurotology, 20, 202-211.
https://doi.org/10.1159/000377616
[18]  van der Jagt, M.A., Briaire, J.J., Verbist, B.M. and Frijns, J.H.M. (2017) Comparison of the Hifocus Mid-Scala and Hifocus 1J Electrode Array: Angular Insertion Depths and Speech Perception Outcomes. Audiology and Neurotology, 21, 316-325.
https://doi.org/10.1159/000448581
[19]  Doshi, J., Johnson, P., Mawman, D., Green, K., Bruce, I.A., Freeman, S., et al. (2015) Straight versus Modiolar Hugging Electrodes. Otology & Neurotology, 36, 223-227.
https://doi.org/10.1097/mao.0000000000000603
[20]  Vohra, V., Andresen, N.S., Carver, C., Dunham, R., Marsiglia, D., Yeagle, J., et al. (2023) Cochlear Implant Electrode Array Design and Speech Understanding. Otology & Neurotology, 45, 136-142.
https://doi.org/10.1097/mao.0000000000004083
[21]  Garaycochea, O., Manrique-Huarte, R., Lazaro, C., Huarte, A., Prieto, C., Alvarez de Linera-Alperi, M., et al. (2020) Comparative Study of Two Different Perimodiolar and a Straight Cochlear Implant Electrode Array: Surgical and Audiological Outcomes. European Archives of Oto-Rhino-Laryngology, 277, 69-76.
https://doi.org/10.1007/s00405-019-05680-6
[22]  Fabie, J.E., Keller, R.G., Hatch, J.L., Holcomb, M.A., Camposeo, E.L., Lambert, P.R., et al. (2018) Evaluation of Outcome Variability Associated with Lateral Wall, Mid-Scalar, and Perimodiolar Electrode Arrays When Controlling for Preoperative Patient Characteristics. Otology & Neurotology, 39, 1122-1128.
https://doi.org/10.1097/mao.0000000000001951
[23]  MacPhail, M.E., Connell, N.T., Totten, D.J., Gray, M.T., Pisoni, D., Yates, C.W., et al. (2022) Speech Recognition Outcomes in Adults with Slim Straight and Slim Modiolar Cochlear Implant Electrode Arrays. Otolaryngology—Head and Neck Surgery, 166, 943-950.
https://doi.org/10.1177/01945998211036339
[24]  Sturm, J.J., Patel, V., Dibelius, G., Kuhlmey, M. and Kim, A.H. (2021) Comparative Performance of Lateral Wall and Perimodiolar Cochlear Implant Arrays. Otology & Neurotology, 42, 532-539.
https://doi.org/10.1097/mao.0000000000002997
[25]  Peters, J.P.M., Bennink, E. and van Zanten, G.A. (2019) Comparison of Place-versus-Pitch Mismatch between a Perimodiolar and Lateral Wall Cochlear Implant Electrode Array in Patients with Single-Sided Deafness and a Cochlear Implant. Audiology and Neurotology, 24, 38-48.
https://doi.org/10.1159/000499154
[26]  Landsberger, D.M., Svrakic, M., Roland, J.T. and Svirsky, M. (2015) The Relationship between Insertion Angles, Default Frequency Allocations, and Spiral Ganglion Place Pitch in Cochlear Implants. Ear & Hearing, 36, e207-e213.
https://doi.org/10.1097/aud.0000000000000163
[27]  Shaul, C., Dragovic, A.S., Stringer, A.K., O’Leary, S.J. and Briggs, R.J. (2018) Scalar Localisation of Peri-Modiolar Electrodes and Speech Perception Outcomes. The Journal of Laryngology & Otology, 132, 1000-1006.
https://doi.org/10.1017/s0022215118001871
[28]  O’Connell, B.P., Hunter, J.B., Gifford, R.H., Rivas, A., Haynes, D.S., Noble, J.H., et al. (2016) Electrode Location and Audiologic Performance after Cochlear Implantation: A Comparative Study between Nucleus CI422 and CI512 Electrode Arrays. Otology & Neurotology, 37, 1032-1035.
https://doi.org/10.1097/mao.0000000000001140
[29]  Jwair, S., Prins, A., Wegner, I., Stokroos, R.J., Versnel, H. and Thomeer, H.G.X.M. (2021) Scalar Translocation Comparison between Lateral Wall and Perimodiolar Cochlear Implant Arrays—A Meta-Analysis. The Laryngoscope, 131, 1358-1368.
https://doi.org/10.1002/lary.29224
[30]  Geerardyn, A., Zhu, M., Verhaert, N. and Quesnel, A.M. (2024) Intracochlear Trauma and Local Ossification Patterns Differ between Straight and Precurved Cochlear Implant Electrodes. Otology & Neurotology, 45, 245-255.
https://doi.org/10.1097/mao.0000000000004102
[31]  Santa Maria, P.L., Gluth, M.B., Yuan, Y., Atlas, M.D. and Blevins, N.H. (2014) Hearing Preservation Surgery for Cochlear Implantation. Otology & Neurotology, 35, e256-e269.
https://doi.org/10.1097/mao.0000000000000561
[32]  Morrel, W.G., Holder, J.T., Dawant, B.M., Noble, J.H. and Labadie, R.F. (2020) Effect of Scala Tympani Height on Insertion Depth of Straight Cochlear Implant Electrodes. Otolaryngology—Head and Neck Surgery, 162, 718-724.
https://doi.org/10.1177/0194599820904941
[33]  Sydlowski, S., Oakley, S., Borton, S., Barrs, D. and Cevette, M. (2010) Negative Effect of Deep Cochlear Implant Electrode Insertion on Speech Perception. Cochlear Implants International, 11, 233-240.
[34]  Schwartz, N., Brown, K.D. and Park, L.R. (2020) Audiologic Outcomes of Cochlear Implantation in Cochlear Malformations: A Comparative Analysis of Lateral Wall and Perimodiolar Electrode Arrays. Otology & Neurotology, 41, e1201-e1206.
https://doi.org/10.1097/mao.0000000000002833
[35]  Wang, B., Cao, K.L., Wang, Y. and Li, H. (2017) [Comparison of Hearing Rehabilitation for Patients with Mondini Malformation after Cochlear Implantation with Different Electrodes]. Journal of Clinical Otorhinolaryngology, Head, and Neck Surgery, 31, 284-289.
[36]  Suhling, M., Salcher, R., Lesinski-Schiedat, A., Lenarz, T. and Schüssler, M. (2018) Hearing Preservation Potential of Different Cochlear Implant Electrodes: Perimodiolar versus Lateral-Wall. Laryngorhinootologie, 97, S267.
https://doi.org/10.1055/s-0038-1640637
[37]  Moran, M., Vandali, A., Briggs, R.J.S., Dettman, S., Cowan, R.S.C. and Dowell, R.C. (2019) Speech Perception Outcomes for Adult Cochlear Implant Recipients Using a Lateral Wall or Perimodiolar Array. Otology & Neurotology, 40, 608-616.
https://doi.org/10.1097/mao.0000000000002189
[38]  Zhan, K.Y., Walia, A., Durakovic, N., Wick, C.C., Buchman, C.A., Shew, M.A., et al. (2023) One-Year Hearing Preservation and Speech Outcomes Comparing Slim Modiolar and Lateral Wall Arrays. Otolaryngology—Head and Neck Surgery, 169, 340-347.
https://doi.org/10.1002/ohn.273
[39]  Park, J.T., Kwak, M.Y., Kim, Y., Lee, J.Y., Kang, W.S., Ahn, J.H., et al. (2021) Short-Term Experience in Cochlear Implantation with Slim Modiolar Electrode Array (CI532): Comparison to Previous Devices. Korean Journal of Otorhinolaryngology-Head and Neck Surgery, 64, 223-231.
https://doi.org/10.3342/kjorl-hns.2019.00745
[40]  Kim, J.-S., Hong, S.H. and Moon, I.J. (2022) Effect of Inner Ear Malformations on Intraoperative ECAP Thresholds and Postoperative Auditory Performance. Laryngoscope Investigative Otolaryngology, 7, 1098-1106.
https://doi.org/10.1002/lio2.836
[41]  Zarowski, A., Molisz, A., Mylanus, E.A.M., Miserus, J.H.M., Leblans, M., van Dinther, J., et al. (2020) Comparison of Electrophysiological Parameters between Perimodiolar and Lateral Wall Electrodes in Paediatric Cochlear Implant Users. European Archives of Oto-Rhino-Laryngology, 277, 2693-2699.
https://doi.org/10.1007/s00405-020-05927-7
[42]  Damarla, V., Saxena, U., Rathna Kumar, S.B., Chacko, G. and Nagabathula, V. (2022) Auditory, Speech and Language Development in Cochlear Implant Children: A One Year Longitudinal Study. Indian Journal of Otolaryngology and Head & Neck Surgery, 74, 3631-3637.
https://doi.org/10.1007/s12070-020-02260-7
[43]  Schrader, J.K.F., Gr?schel, M., Szczepek, A.J. and Olze, H. (2026) Long-Term Auditory, Tinnitus, and Psychological Outcomes after Cochlear Implantation in Single-Sided Deafness: A Two-Year Prospective Study. Journal of Clinical Medicine, 15, Article No. 644.
https://doi.org/10.3390/jcm15020644
[44]  Canfarotta, M.W., Dillon, M.T., Thompson, N.J., Selleck, A.M., Dedmon, M.M. and Brown, K.D. (2025) Effects of Insertion Depth and Modiolar Proximity on Cochlear Implant Speech Recognition Outcomes with a Precurved Electrode Array. Otology & Neurotology, 46, 272-278.
https://doi.org/10.1097/mao.0000000000004405

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133