High-Viscosity versus Low-Viscosity Bone Cement in the Management of Osteoporotic Vertebral Compression Fractures: A Systematic Review and Meta-Analysis
Background: Clinical uncertainty persists regarding the optimal cement viscosity for vertebral augmentation in osteoporotic vertebral compression fractures (OVCFs). Objective: To compare the efficacy and safety of high-viscosity (HVC) versus low-viscosity (LVC) bone cement in percutaneous vertebroplasty for OVCFs. Methods: PubMed, Embase, Cochrane Library, Web of Science, and China National Knowledge Infrastructure (CNKI) were searched from inception to April 15, 2026, without language restriction; however, only English and Chinese language publications were eligible. The primary outcome was cement leakage rate; secondary outcomes included pain (visual analog scale, VAS), functional disability (Oswestry Disability Index, ODI), vertebral height restoration, and complications. Random-effects meta-analysis was performed, with effect sizes expressed as odds ratios (ORs) or mean differences (MDs), along with 95% confidence intervals (CIs). Results: Four studies (1 RCT, 3 retrospective cohorts) comprising 218 patients (110 HVC, 108 LVC) with 235 treated vertebrae were included. In separate meta-analyses by unit of analysis, limited evidence suggested lower cement leakage with HVC: per-patient OR 0.19 (95% CI 0.09 - 0.40) and per-vertebra OR 0.22 (95% CI 0.08 - 0.63). No significant differences were observed between groups for final follow-up VAS scores (MD ?0.06, 95% CI ?0.19 to 0.07, p = 0.35; I2 = 0%) or ODI scores (MD ?0.28, 95% CI ?2.94 to 2.38, p = 0.84; I2 = 31%). Vertebral height restoration and complication rates were similar between groups, but these findings were based on sparse narrative data. Conclusion: Low-certainty evidence suggests that high-viscosity cement may reduce radiographic cement leakage compared with low-viscosity cement in PVP, but available data do not show superior pain relief or functional recovery. Because the evidence base is small and includes mixed study designs, conclusions should be interpreted cautiously. Large, adequately powered randomized controlled trials are needed.
Xiao, P.L., Cui, A.Y., Hsu, C.J., Peng, R., Jiang, N., Xu, X.H., et al. (2022) Global, Regional Prevalence, and Risk Factors of Osteoporosis According to the World Health Organization Diagnostic Criteria: A Systematic Review and Meta-analysis. OsteoporosisInternational, 33, 2137-2153. https://doi.org/10.1007/s00198-022-06454-3
[3]
Delmas, P.D., van de Langerijt, L., Watts, N.B., Eastell, R., Genant, H., Grauer, A., et al. (2005) Underdiagnosis of Vertebral Fractures Is a Worldwide Problem: The IMPACT Study. JournalofBoneandMineralResearch, 20, 557-563. https://doi.org/10.1359/jbmr.041214
[4]
Lewis, G. (2017) Properties of Nanofiller-Loaded Poly (Methyl Methacrylate) Bone Cement Composites for Orthopedic Applications: A Review. JournalofBiomedicalMaterialsResearchPartB: AppliedBiomaterials, 105, 1260-1284. https://doi.org/10.1002/jbm.b.33643
[5]
Ren, H., Feng, T., Cao, J., Hu, Y., Yu, D., Pan, S., et al. (2022) A Retrospective Study to Evaluate the Effect of Dynamic Fracture Mobility on Cement Leakage in Percutaneous Vertebroplasty and Percutaneous Kyphoplasty in 286 Patients with Osteoporotic Vertebral Compression Fractures. MedicalScienceMonitor, 28, e935080. https://doi.org/10.12659/msm.935080
[6]
Li, Q., Long, X., Wang, Y., Guan, T., Fang, X., Guo, D., et al. (2021) Clinical Observation of Two Bone Cement Distribution Modes after Percutaneous Vertebroplasty for Osteoporotic Vertebral Compression Fractures. BMCMusculoskeletalDisorders, 22, Article No. 577. https://doi.org/10.1186/s12891-021-04480-6
[7]
Wang, M., Zhang, L., Fu, Z., Wang, H. and Wu, Y. (2021) Selections of Bone Cement Viscosity and Volume in Percutaneous Vertebroplasty: A Retrospective Cohort Study. WorldNeurosurgery, 150, e218-e227. https://doi.org/10.1016/j.wneu.2021.02.133
[8]
Buchbinder, R., Johnston, R.V., Rischin, K.J., Homik, J., Jones, C.A., Golmohammadi, K., et al. (2018) Percutaneous Vertebroplasty for Osteoporotic Vertebral Compression Fracture. CochraneDatabaseofSystematicReviews, 4, CD006349. https://doi.org/10.1002/14651858.cd006349.pub4
[9]
Ebeling, P.R., Akesson, K., Bauer, D.C., Buchbinder, R., Eastell, R., Fink, H.A., et al. (2019) The Efficacy and Safety of Vertebral Augmentation: A Second ASBMR Task Force Report. JournalofBoneandMineralResearch, 34, 3-21. https://doi.org/10.1002/jbmr.3653
[10]
Yang, K., Zhu, X., Sun, X., Shi, H., Sun, L. and Ding, H. (2025) Bone Cement Distribution Patterns in Vertebral Augmentation for Osteoporotic Vertebral Compression Fractures: A Systematic Review. JournalofOrthopaedicSurgeryandResearch, 20, Article No. 568. https://doi.org/10.1186/s13018-025-05868-z
[11]
Sun, Y., Zhang, Y., Ma, H., Tan, M. and Zhang, Z. (2023) Therapeutic Efficacy and Safety of Percutaneous Curved Vertebroplasty in Osteoporotic Vertebral Compression Fractures: A Systematic Review and Meta‐analysis. OrthopaedicSurgery, 15, 2492-2504. https://doi.org/10.1111/os.13800
[12]
Page, M.J., McKenzie, J.E., Bossuyt, P.M., Boutron, I., Hoffmann, T.C., Mulrow, C.D., et al. (2021) The PRISMA 2020 Statement: An Updated Guideline for Reporting Systematic Reviews. BMJ, 372, n71. https://doi.org/10.1136/bmj.n71
[13]
Higgins, J.P.T., Thomas, J., Chandler, J., Cumpston, M., Li, T., Page, M.J. and Welch, V.A. (2022) Cochrane Handbook for Systematic Reviews of Interventions. Version 6.3. Cochrane.
[14]
Cochrane Effective Practice and Organisation of Care (2017) Data Collection form for Intervention Reviews. EPOC Resources for Review Authors. https://epoc.cochrane.org/sites/epoc.cochrane.org/files/uploads/datacollectionchecklist.pdf
[15]
Zhang, L., Wang, J., Feng, X., Tao, Y., Yang, J., Wang, Y., et al. (2015) A Comparison of High Viscosity Bone Cement and Low Viscosity Bone Cement Vertebroplasty for Severe Osteoporotic Vertebral Compression Fractures. ClinicalNeurologyandNeurosurgery, 129, 10-16. https://doi.org/10.1016/j.clineuro.2014.11.018
[16]
Li, K., Feng, H., Luo, D., Zhang, W., Yang, K., Ji, C., et al. (2020) Efficacy and Safety of High-Viscosity Cement in Percutaneous Vertebroplasty for Treatment of Osteoporotic Vertebral Compression Fractures: A Retrospective Cohort Study. Medicine, 99, e20515. https://doi.org/10.1097/md.0000000000020515
[17]
Zhang, Z., Yang, J., Jiang, H., Lai, Z., Wu, F., Pan, Y., et al. (2017) An Updated Comparison of High-and Low-Viscosity Cement Vertebroplasty in the Treatment of Osteoporotic Thoracolumbar Vertebral Compression Fractures: A Retrospective Cohort Study. InternationalJournalofSurgery, 43, 126-130. https://doi.org/10.1016/j.ijsu.2017.05.067
[18]
Zeng, T.H., Wang, Y.M., Yang, X.J., Xiong, J.Y. and Guo, D.Q. (2015) The Clinical Comparative Study on High and Low Viscosity Bone Cement Application in Vertebroplasty. International Journal of Clinical and Experimental Medicine, 8, 18855-18860.
[19]
Wang, Q., Sun, C., Zhang, L., Wang, L., Ji, Q., Min, N., et al. (2022) High-versus Low-Viscosity Cement Vertebroplasty and Kyphoplasty for Osteoporotic Vertebral Compression Fracture: A Meta-Analysis. EuropeanSpineJournal, 31, 1122-1130. https://doi.org/10.1007/s00586-022-07150-w
[20]
Zhan, Y., Jiang, J., Liao, H., Tan, H. and Yang, K. (2017) Risk Factors for Cement Leakage after Vertebroplasty or Kyphoplasty: A Meta-Analysis of Published Evidence. WorldNeurosurgery, 101, 633-642. https://doi.org/10.1016/j.wneu.2017.01.124
[21]
Kou, Y., Zhang, D., Zhang, J., Han, N. and Yang, M. (2022) Vertebroplasty with High‐viscosity Cement versus Conventional Kyphoplasty for Osteoporotic Vertebral Compression Fractures: A Meta-Analysis. ANZJournalofSurgery, 92, 2849-2858. https://doi.org/10.1111/ans.17894