Assessment Analysis of Neutral to Earth Voltage (NTEV) in the Distribution System at the Government Building Using Statistical and Analytical Methods Analysis
Elevated neutral-to-earth voltage or simply known as Neutral-To-Earth Voltage (NTEV), and the related phenomenon called stray voltage is typically caused by fundamental frequency currents returning to the source via the neutral conductor and earth. The nature of grounded power systems results in the fact that the neutral conductors are not always at zero potential with respect to the earth. This study also aims to investigate the effect of Neutral to Earth voltage on power distribution. Using the appropriate measurement equipment, the data logger was attached to Main Switch Boards to record data for 4 days for monitoring, recording, and analyzing frequency, harmonics, and voltage fluctuation. In addition, the data logger for this measurement tool have been installed on the main switchboard (MSB1) in Agensi Nuklear Malaysia. This study performed a comparison of peak time (8 am-5 pm) and non-peak time (6 pm-6 am) and also the correlation between each parameter. Based on the result of standard deviation and mean, all parameters deviate very closely to the mean value. The skewness value provide evidence that the measured data was distributed close to the nominal specification. Through correlation analysis, at the end of this study it was found that the correlation between NTEV and THDV of each phase in the first location has a very high correlation.
References
[1]
IEEE (2019) Recommended Practice for Monitoring Electric Power Quality. http://www.ieee.org/web/aboutus/whatis/policies/p9-26.html
[2]
Shafie, M.A., Singh, H. and Rahman, M.Q.A. (2010). Harmonic and Neutral to Ground Voltage Reduction Using Isolation Transformer. 2010 IEEE International Conference on Power and Energy. Kuala Lumpur, 29 November-1 December 2010, 561-566. https://doi.org/10.1109/PECON.2010.5697645
[3]
Mirus International Inc (2021) A Practical and Effective Way of Applying IEEE Std 519-2014 Harmonic Limits.
[4]
Malaysia, S.T. (2017) Distribution Code for Peninsular Malaysia, Sabah & F.T. Labuan (Amendments) 2017. https://www.st.gov.my/
[5]
Variz, A.M., Pereira, J.L.R., Carneiro, S. and Barbosa, P.G. (2009) Harmonic Analysis of the Power Distribution Neutral-To-Earth Voltage (NEV) Test Case Using Four-Wire Three-Phase Harmonic Current Injection Method. 2009 IEEE Power & Energy Society General Meeting. Calgary, 26-30 July 2009, 1-7. https://doi.org/10.1109/PES.2009.5275758
[6]
Johari, A. and St, J. (2010) Document Control the Malaysian Grid Code.
[7]
Al-Shetwi, A.Q. and Sujod, M.Z. (2018) Harmonic Distortion and Voltage Imbalance Study of Photovoltaic Power Plant Connected to the Malaysian Grid Muhamad Zahim Sujod Harmonic Distortion and Voltage Imbalance Study of Photovoltaic Power Plant Connected to the Malaysian Grid. https://www.researchgate.net/publication/323642562
[8]
Rohafauzi, S., Kassim, M., Ja’Afar, H., Rustam, I., Miskon, M.T. and Pakhrudin, N.S.M. (2023) Descriptive Analysis on Data of Stingless Bee IoT Application Monitoring System. 2023 IEEE 13th International Conference on System Engineering and Technology (ICSET), Shah Alam, 2 October 2023, 159-164. https://doi.org/10.1109/icset59111.2023.10295071
[9]
Dimi?, G., Rancic, D., Proni?-Ran?i?, O., et al. (2019) Descriptive Statistical Analysis in the Process of Educational Data Mining. 2019 14th International Conference on Advanced Technologies, Systems and Services in Telecommunications, Ni? Serbia, 23-25 October 2019, 388-391.
[10]
Maulana, B.W., Utomo, S.B., Anam, K. and Bilfaqih, I. (2023) Analysis of Movement Patterns Based on Electroencephalograph Signals Using Pearson Correlation Coefficient. 2023 International Seminar on Intelligent Technology and Its Applications (ISITIA), Surabaya, 26 July 2023, 593-597. https://doi.org/10.1109/isitia59021.2023.10220971