全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Effect of Pipe Mass Vertical Distribution on Seismic Demands in Industrial Steel Pipe Racks

DOI: 10.4236/ojce.2026.162011, PP. 226-248

Keywords: Pipe Rack, Seismic Response, Nonlinear Time-History Analysis, Mass Distribution, Vertical Irregularity

Full-Text   Cite this paper   Add to My Lib

Abstract:

Industrial pipe rack structures support piping systems carrying hazardous fluids at multiple elevations. In current seismic design practice, pipe mass is typically idealised as uniformly distributed across all levels, yet the actual distribution varies considerably depending on the operational configuration. The structural consequences of this idealisation on nonlinear seismic demands have not been systematically investigated. This study examines the effect of vertical pipe mass distribution on the nonlinear seismic response of a representative multi-level steel pipe rack structure. A finite element model is developed in SAP2000 with fiber-section hinges and link elements for bracing. Four pipe mass distribution cases—uniform, top-heavy, bottom-heavy, and mid-concentrated—are defined with constant total pipe mass. Nonlinear time-history analyses are performed under eleven spectrally matched ground motion pairs applied separately in the longitudinal and transverse directions, yielding eighty-eight analysis runs. The uniform distribution produces the highest seismic demands in both directions, with a maximum interstory drift ratio of 7.19% (longitudinal) and 3.10% (transverse). The non-uniform distributions reduce the maximum interstory drift ratio by 45% - 59%, peak roof displacement by 34% - 59%, and normalised base shear by 64% - 71% relative to the uniform baseline. The demand reductions are driven by a fundamental period shift exceeding a factor of 2.5, repositioning the structure across distinct spectral regions. When assessed against performance limit states, the uniform case exceeds collapse prevention in the braced direction, while non-uniform cases remain within life safety in the transverse direction. The uniform pipe mass assumption is shown to be inherently conservative; accounting for the actual distribution could shift the performance classification by one or more levels and enable more economical designs.

References

[1]  Di Sarno, L. and Karagiannakis, G. (2020) Petrochemical Steel Pipe Rack: Critical Assessment of Existing Design Code Provisions and a Case Study. International Journal of Steel Structures, 20, 232-246.
https://doi.org/10.1007/s13296-019-00280-w
[2]  di Roseto, A.d.L., Palmeri, A. and Gibb, A.G. (2017) Performance-Based Seismic Design of a Modular Pipe-Rack. Procedia Engineering, 199, 3564-3569.
https://doi.org/10.1016/j.proeng.2017.09.519
[3]  Jayarajan, P. (2020) Seismic Fragility Assessment of a Pipe Rack Structure in a Petrochemical Complex by Incremental Dynamic Analysis. Journal of Structural Engineering (Madras), 47, 408-415.
https://www.academia.edu/44791802/Seismic_fragility_assessment_of_a_pipe_rack_structure_in_a_petrochemical_complex_by_incremental_dynamic_analysis
[4]  Paolacci, F., Reza, M.S. and Bursi, O.S. (2011) Seismic Analysis and Component Design of Refinery Piping Systems. III ECCOMAS Thematic Conference on Computational Methods in Structural Dynamics and Earthquake Engineering (COMPDYN 2011), Corfu, 25-28 May 2011, 1-24.
https://congress.cimne.com/eccomas/proceedings/compdyn2011/compdyn2011_full/360.pdf
[5]  Di Sarno, L. and Karagiannakis, G. (2020) On the Seismic Fragility of Pipe Rack—Piping Systems Considering Soil-Structure Interaction. Bulletin of Earthquake Engineering, 18, 2723-2757.
https://doi.org/10.1007/s10518-020-00797-0
[6]  European Committee for Standardization (CEN) (2012) Metallic Industrial Piping-Part 3: Design and Calculation. EN 13480-3:2012.
[7]  ASCE/SEI (2022) Minimum Design Loads and Associated Criteria for Buildings and Other Structures. ASCE/SEI 7-22, American Society of Civil Engineers.
[8]  Karagiannakis, G. and Di Sarno, L. (2021) Seismic Performance-Based Assessment of a RC Pipe Rack Accounting for Dynamic Interaction. Structures, 34, 1338-1352.
[9]  Al-Ali, A.A.K. and Krawinkler, H. (1998) Effects of Vertical Irregularities on Seismic Behavior of Building Structures. Report No. 130, John A. Blume Earthquake Engineering Center, Stanford University.
https://purl.stanford.edu/qh189ph3062
[10]  Nady, O., Mahfouz, S.Y. and Taher, S.E.F. (2022) Quantification of Vertical Irregularities for Earthquake Resistant Reinforced Concrete Buildings. Buildings, 12, Article No. 1160.
https://doi.org/10.3390/buildings12081160
[11]  Computers and Structures, Inc. (2025) SAP2000: Linear and Nonlinear Static and Dynamic Analysis of Three-Dimensional Structures. CSI.
[12]  Seismosoft (2018) SeismoStruct—The Ultimate Finite Element Package for Seismic Analysis.
https://seismosoft.com/products/seismostruct/
[13]  Pacific Earthquake Engineering Research Center (PEER) (2013) PEER NGA-West2 Ground Motion Database. University of California.
https://ngawest2.berkeley.edu
[14]  Baker, J.W. (2011) Conditional Mean Spectrum: Tool for Ground-Motion Selection. Journal of Structural Engineering, 137, 322-331.
https://doi.org/10.1061/(asce)st.1943-541x.0000215
[15]  Shahi, S.K. and Baker, J.W. (2014) An Efficient Algorithm to Identify Strong-Velocity Pulses in Multicomponent Ground Motions. Bulletin of the Seismological Society of America, 104, 2456-2466.
https://doi.org/10.1785/0120130191
[16]  Seismosoft (2024) SeismoMatch—Precision Response Spectrum Matching.
https://seismosoft.com/products/seismomatch/
[17]  Al Atik, L. and Abrahamson, N. (2010) An Improved Method for Nonstationary Spectral Matching. Earthquake Spectra, 26, 601-617.
https://doi.org/10.1193/1.3459159
[18]  Grant, D.N. and Diaferia, R. (2011) Assessing Adequacy of Spectrum-Matched Ground Motions for Nonlinear Dynamic Analysis. Earthquake Engineering and Structural Dynamics, 40, 1293-1311.
[19]  Heo, Y., Kunnath, S.K. and Abrahamson, N. (2011) Amplitude-Scaled versus Spectrum-Matched Ground Motions for Seismic Performance Assessment. Journal of Structural Engineering, 137, 278-288.
https://doi.org/10.1061/(asce)st.1943-541x.0000340
[20]  ASCE/SEI (2017) Seismic Evaluation and Retrofit of Existing Buildings. ASCE/SEI 41-17, American Society of Civil Engineers.
[21]  Chopra, A.K. (2020) Dynamics of Structures: Theory and Applications to Earth-quake Engineering. 5th Edition, Pearson.
[22]  Federal Emergency Management Agency (FEMA) (2000) Prestandard and Commentary for the Seismic Rehabilitation of Buildings. FEMA 356, Washington.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133