|
|
Modern Physics 2026
光纤开腔法布里–珀罗干涉仪的折射率传感特性研究
|
Abstract:
本文提出并设计了一种基于光纤开腔法布里–珀罗干涉仪(Fabry-Perot Interferometer, FPI)的折射率传感器。该传感器采用全开腔结构与U型玻璃槽封装,通过单模光纤端面与镀金玻璃圆柱构成干涉腔,有效提升液体导入能力与结构稳定性。随着待测溶液折射率变化,FPI干涉光谱特征峰发生明显漂移,通过对特征波长解调,实现了溶液折射率的高精度测量。实验结果表明,在折射率范围1.3329~1.3343内,传感器折射率灵敏度达到1149.265 nm/RIU,线性拟合系数为0.998。对不同腔长结构的对比实验表明,该传感器具有良好的重复性与工艺一致性,灵敏度偏差小于0.5%。此外,稳定性测试结果显示,在恒定环境下120 min内波长漂移小于0.091 nm,对应折射率误差约为7.9 × 10?5 RIU。该传感器具有结构简单、成本低、抗腐蚀性强及良好稳定性等优点,在生化检测与工业过程监测等领域具有良好的应用前景。
This paper proposed and designed a refractive index sensor based on a fiber-optic open-cavity Fabry-Perot interferometer (FPI). The sensor employs a fully open-cavity structure encapsulated in a U-shaped glass channel, in which the interference cavity is constructed by the end face of a single-mode fiber and a gold-plated glass cylinder. This design effectively improves liquid intake capacity and structural stability of the sensor. The characteristic peaks in the FPI interference spectrum exhibit a remarkable wavelength shift with the variation of the external refractive index, and high-precision measurement of the solution’s refractive index is achieved by demodulating the characteristic wavelengths. Experimental results indicate that within the refractive index range of 1.3329 to 1.3343, the sensor achieves a refractive index sensitivity of 1149.265 nm/RIU, with a linearity coefficient of 0.998. Comparative experiments on structures with different cavity lengths demonstrate that the sensor exhibits excellent repeatability and process consistency, with a sensitivity deviation of less than 0.5%. Furthermore, stability test results show that under constant environmental conditions, the wavelength drift over 120 minutes is less than 0.091 nm, corresponding to a refractive index error of approximately 7.9 × 10?5 RIU. This sensor offers advantages such as a simple structure, low cost, strong corrosion resistance, and high stability, and holds promising application prospects in fields such as biochemical detection and industrial process monitoring.
| [1] | 李乾坤, 丁美琪, 桂林, 等. 基于微波光子滤波器射频强度的叶绿素检测研究[J]. 中国激光, 2023, 50(21): 2107403. |
| [2] | Li, G., Yang, S. and Wu, C. (2024) Seeing More Clearly: Improving the Resolution of Ocean Salinity Measurements Using a Fabry-Perot Resonant Cavity. Optics and Lasers in Engineering, 181, Article 108356. https://doi.org/10.1016/j.optlaseng.2024.108356 |
| [3] | Mahmoodi, Y. and Fathi, D. (2021) High-performance Refractive Index Sensor for Oil Derivatives Based on MWCNT Photonic Crystal Microcavity. Optics & Laser Technology, 138, Article 106865. https://doi.org/10.1016/j.optlastec.2020.106865 |
| [4] | Shin, H.J., Lim, J., Park, K. and Ok, G. (2024) State-of-the-Art Nondestructive High-Speed Raster Scanning Inspection for Food Safety and Quality Using Terahertz Refractive Index Mapping. Food Chemistry Advances, 4, Article 100685. https://doi.org/10.1016/j.focha.2024.100685 |
| [5] | Liu, Y. and Qu, S. (2014) Optical Fiber Fabry-Perot Interferometer Cavity Fabricated by Femtosecond Laser-Induced Water Breakdown for Refractive Index Sensing. Applied Optics, 53, 469-474. https://doi.org/10.1364/ao.53.000469 |
| [6] | Geng, J. and Kishi, N. (2025) A Temperature-Insensitive Refractive Index Sensor Based on In-Line Mach-Zehnder Interferometer with Micro Spindle Structures and Photonic Crystal Fibers. Optical Fiber Technology, 89, Article 104039. https://doi.org/10.1016/j.yofte.2024.104039 |
| [7] | Bai, X., Wang, X., Zhang, M., Wang, M., Yang, B., Su, J., et al. (2025) An Optical Michelson Interferometric Spectrometer-Based Seawater Density Sensor with Improved Long-Term Stability in the Deep-Sea Trial. Measurement, 250, Article 117230. https://doi.org/10.1016/j.measurement.2025.117230 |
| [8] | Fan, X., Zhang, H., Feng, W., Xu, Y. and Qi, Y. (2025) Drop-Shaped Single-Mode Microfiber with Sagnac Loop Based on Coupling Effect for Refractive Index Sensing. Sensors and Actuators A: Physical, 389, Article 116535. https://doi.org/10.1016/j.sna.2025.116535 |
| [9] | Liu, X., Wang, Q. and Wang, D.N. (2022) Ultra Compact and Sensitive Optical Fiber Interferometric Refractive Index Sensor. Optik, 254, Article 168642. https://doi.org/10.1016/j.ijleo.2022.168642 |
| [10] | Tian, J., Lu, Y., Zhang, Q. and Han, M. (2013) Microfluidic Refractive Index Sensor Based on an All-Silica In-Line Fabry-Perot Interferometer Fabricated with Microstructured Fibers. Optics Express, 21, 6633-6639. https://doi.org/10.1364/oe.21.006633 |
| [11] | Jiang, J., Zhao, Y., Yang, Y., Wang, Y., He, X., Yang, W., et al. (2019) All-Fiber Fabry-Perot Interferometer for Liquid Refractive Index Measurement. Journal of Russian Laser Research, 40, 370-374. https://doi.org/10.1007/s10946-019-09813-4 |
| [12] | Gutiérrez, C.E. (2013) Refraction Problems in Geometric Optics. In: Capogna, L., Guan, P., Gutiérrez, C.E., et al., Eds., Fully Nonlinear PDEs in Real and Complex Geometry and Optics, Springer International Publishing, 95-150. https://doi.org/10.1007/978-3-319-00942-1_3 |