Phacoemulsification is one of the most widely performed surgeries in the world. Although it has several complications reported in the literature, it is considered a safe procedure with low complication rates. This is mainly due to the development and systematization of surgical techniques, combined with growing experience in the field. Previous studies have reported that the main factor related to increased intraocular pressure in the early post-operative period is the presence of viscoelastic in the anterior chamber. The aim of this study is to describe a systematized technique for aspirating ophthalmic viscosurgical devices (OVD) in phacoemulsification and to evaluate its impact on post-operative intraocular pressure. We used a case-control design, comparing 2 groups of patients, the case group in which surgery was performed using the technique described and the control group with those who did not use the technique. This study aims to help prevent complications and improve post-operative results in cataract surgery.
References
[1]
Higashide, T. and Sugiyama, K. (2008) Use of Viscoelastic Substance in Ophthalmic Surgery—Focus on Sodium Hyaluronate. Clinical Ophthalmology, 2, 21-30.
[2]
Brown, T. and Clark, H. (2019) The Role of Viscoelastics in Cataract Surgery. Ophthalmic Surgery, Lasers and Imaging Retina, 50, 90-95.
[3]
Almalki, S., Abubaker, A., Alsabaani, N.A. and Edward, D.P. (2016) Causes of Elevated Intraocular Pressure Following Implantation of Phakic Intraocular Lenses for Myopia. International Ophthalmology, 36, 259-265. https://doi.org/10.1007/s10792-015-0112-4
[4]
Althomali, T.A. (2016) Viscoelastic Substance in Prefilled Syringe as an Etiology of Toxic Anterior Segment Syndrome. Cutaneous and Ocular Toxicology, 35, 237-241. https://doi.org/10.3109/15569527.2015.1082579
[5]
Arshinoff, S.A. and Wong, E. (2003) Understanding, Retaining, and Removing Dispersive and Pseudodispersive Ophthalmic Viscosurgical Devices. Journal of Cataract and Refractive Surgery, 29, 2318-2323. https://doi.org/10.1016/j.jcrs.2003.09.045
[6]
Auffarth, G.U., Holzer, M.P., Visessook, N., Apple, D.J. and Völcker, H.E. (2004) Removal Times for a Dispersive and a Cohesive Ophthalmic Viscosurgical Device Correlated with Intraocular Lens Material. Journal of Cataract and Refractive Surgery, 30, 2410-2414. https://doi.org/10.1016/j.jcrs.2004.03.039
[7]
Auffarth, G.U., Holzer, M.P., Vissesook, N., Apple, D.J. and Völcker, H.E. (2004) Removal Times and Techniques of a Viscoadaptive Ophthalmic Viscosurgical Device. Journal of Cataract and Refractive Surgery, 30, 879-883. https://doi.org/10.1016/j.jcrs.2003.08.031
[8]
Dada, V.K., Sharma, N., Pangtey, M.S. and Dada, T. (2001) Modification of the Aspiration Port to Aid OVD Removal and Prevent Posterior Capsule Tear. Journal of Cataract and Refractive Surgery, 27, 341. https://doi.org/10.1016/s0886-3350(01)00776-3
[9]
Kanclerz, P. and Wang, X. (2019) Post-operative Capsular Bag Distension Syndrome—Risk Factors and Treatment. Seminars in Ophthalmology, 34, 409-419. https://doi.org/10.1080/08820538.2019.1640750
[10]
Kreis, A.J., Nguyen, T.T., Jhanji, V. and Vajpayee, R.B. (2010) ‘Flow Out Technique’ for Safe and Complete Removal of Ophthalmic Viscosurgical Devices after Phacoemulsification Cataract Surgery. Eye&ContactLens: Science&ClinicalPractice, 36, 356-357. https://doi.org/10.1097/icl.0b013e3181f8bc3e
[11]
Pandey, S.K., Werner, L., Apple, D.J., et al. (2003) Viscoanesthesia. Part III: Removal Time of OVD/Viscoanesthetic Solutions from the Capsular Bag of Postmortem Human Eyes. JournalofCataractandRefractiveSurgery, 29, 563-567. https://doi.org/10.1016/s0886-3350(02)01615-2
[12]
Shimizu, K., Kobayashi, K., Takayama, S. and Zhaobin, G. (2008) Preloaded Injector for Intraocular Lens Implantation without the Use of Ophthalmic Viscosurgical Devices. Journal of Cataract and Refractive Surgery, 34, 1157-1160. https://doi.org/10.1016/j.jcrs.2008.03.034
[13]
Takahashi, H., Suzuki, H., Shiwa, T. and Sakamoto, A. (2006) Alteration of Free Radical Development by Ophthalmic Viscosurgical Devices in Phacoemulsification. Journal of Cataract and Refractive Surgery, 32, 1545-1548. https://doi.org/10.1016/j.jcrs.2006.04.026
[14]
Aguirre Balsalobre, F., Orts Vila, P., Hernández Pardines, F., García Conca, V., et al. (2018) Evaluation of Two Techniques for Irrigation/Aspiration Retrolental Viscoelastic Removal in Cataract Surgery. Journal of Clinical Ophthalmology and Research, 5, 1-6.
[15]
Zetterström, C., Wejde, G. and Taube, M. (2002) Healon5: Comparison of 2 Removal Techniques. JournalofCataractandRefractiveSurgery, 28, 1561-1564. https://doi.org/10.1016/s0886-3350(02)01271-3