Application of In-Situ Live-Line Pole Replacement Technology in Iron Tower Construction

DOI: 10.4236/ojce.2026.161005, PP. 83-99

Keywords: Tower, Tower Line Shape, Numerical Analysis, Monitoring

Full-Text   Cite this paper   Add to My Lib

Abstract:

The transmission tower serves as a critical component of the national power transmission system, and together with overhead transmission lines, constitutes a nationwide power grid. However, as an indispensable part of transmission line infrastructure, it is highly susceptible to extreme structural failures such as overturning and collapse induced by external loads or material corrosion, which severely undermine the operational stability and safety of transmission lines. This paper proposes an innovative construction technique for replacing structural members of high-voltage transmission towers. The proposed method ensures the stability of the local member system during the replacement process and guides the construction under the coupled interaction of the tower-line system. A form-finding analysis of the ground wire is performed, deriving a mathematical model that characterizes the profile of transmission lines under combined self-weight and wind load conditions. By applying the equal-strength replacement principle and numerical simulation methods, the feasibility and practicality of in-situ live-line member replacement are verified. This method enables construction and maintenance work by replacing partial structural members without the need for complete tower dismantlement. Monitoring results indicate that the deformation deviations of the tower in all directions are maintained within the allowable safety range. Compared with conventional methods, this technique facilitates rapid in-situ live-line repair, offering remarkable advantages in terms of construction duration and economic efficiency.

References

[1]  Tang, Z., Han, C., Li, H., Fan, Z., Sun, K., Huang, Y., et al. (2024) Automatic 3D Modeling Technique for Transmission Towers from 2D Drawings. Mathematics, 12, Article 3767.
https://doi.org/10.3390/math12233767
[2]  Baran, E., Akis, T., Sen, G. and Draisawi, A. (2016) Experimental and Numerical Analysis of a Bolted Connection in Steel Transmission Towers. Journal of Constructional Steel Research, 121, 253-260.
https://doi.org/10.1016/j.jcsr.2016.02.009
[3]  Bi, W., Tian, L., Li, C., Ma, Z. and Pan, H. (2023) Wind-Induced Failure Analysis of a Transmission Tower-Line System with Long-Term Measured Data and Orientation Effect. Reliability Engineering & System Safety, 229, Article ID: 108875.
https://doi.org/10.1016/j.ress.2022.108875
[4]  Xu, Z., Zhang, T., Ge, X.D., Gao, F., Zhang, L.Y., Zhang, X. and Tian, L. (2021) Uncertainty Analysis of Transmission Tower-Line System under Wind Load. Journal of Shandong University (Engineering Science Edition), 51, 1-7.
[5]  Yang, X.J., Jinshan, M., Zhang, J.G. and Lei, Y. (2021) Effective Simulation of Random Pulsating Wind Field in Transmission Tower-Line System Based on Interpolation and Dimensionality Reduction Methods. Vibration and Shock, 40, 77-83.
[6]  Cao, M.G., Kuang, C.L., Wang, Y., He, C., Zheng, C. (2025) Mechanism and Wind Resistance Performance Assessment of Internal Cable Reinforcement for Transmission Tower under Extreme Winds. Journal of Tsinghua University (Science and Technology), 1-10.
https://doi.org/10.16511/j.cnki.qhdxxb.2026.26.003
[7]  Liu, M.L., Lu, H.K., Luo, K., Wang, M.J., Fan, J.R. and Chi, W. (2020) Numerical Simulation of Wind-Induced Response of Transmission Tower-Line System under Real Mountain Terrain Conditions. Vibration and Shock, 39, 232-239.
[8]  Liu, X., Xia, K., Gao, Y., Liu, S. and Ren, X. (2011) Study on Strengthening the Structure and Its Design for the Transmission Tower. Journal of Xi’an University of Architecture & Technology, 43, 838-844.
[9]  Chen, K. and Shi, Y. (2023) In-Situ Live Jacking Technology of Corner Transmission Tower. Sustainable Energy Technologies and Assessments, 58, Article ID: 103332.
https://doi.org/10.1016/j.seta.2023.103332
[10]  Dinis, P.B., Camotim, D. and Silvestre, N. (2012) On the Mechanics of Thin-Walled Angle Column Instability. Thin-Walled Structures, 52, 80-89.
https://doi.org/10.1016/j.tws.2011.12.007
[11]  Lu, C., Ma, X. and Mills, J.E. (2018) Cyclic Performance of Bolted Cruciform and Splice Connectors in Retrofitted Transmission Tower Legs. Thin-Walled Structures, 122, 264-285.
https://doi.org/10.1016/j.tws.2017.10.020
[12]  Oszvald, K., Tomka, P. and Dunai, L. (2016) The Remaining Load-Bearing Capacity of Corroded Steel Angle Compression Members. Journal of Constructional Steel Research, 120, 188-198.
https://doi.org/10.1016/j.jcsr.2016.01.003
[13]  Wang, J., Fu, X. and Li, H.N. (2020) Multi-Factor Wind-Induced Dynamic Response Analysis of Transmission Tower-Line System. Journal of Shenyang Jianzhu University (Natural Science Edition), 36, 1-10.
[14]  Lu, C., Ma, X. and Mills, J.E. (2015) Modeling of Retrofitted Steel Transmission Towers. Journal of Constructional Steel Research, 112, 138-154.
https://doi.org/10.1016/j.jcsr.2015.04.005
[15]  Tapia-Hernández, E., Ibarra-González, S. and De-León-Escobedo, D. (2016) Collapse Mechanisms of Power Towers under Wind Loading. Structure and Infrastructure Engineering, 13, 766-782.
https://doi.org/10.1080/15732479.2016.1190765
[16]  Ministry of Housing and Urban-Rural Development of PRC (2017) Standard for Design of Steel Structures. GB 50017-2017, China Architecture & Building Press.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133