MV distribution networks are exposed to various types of short-circuit faults generating high currents that can affect stability, power quality, and equipment safety. This article presents an in-depth analysis of short-circuit current behavior in an MV distribution network incorporating a shunt-type static reactive power compensator (DSTATCOM). Using simulations performed in MATLAB/Simulink, the impact of the DSTATCOM is evaluated for single-phase, two-phase, and three-phase faults. The results obtained demonstrate a significant reduction in fault current amplitudes, mitigation of voltage sags, and overall improvement in network stability.
References
[1]
Bhattacharya, S. (2012) Applications of D-STATCOM Using MATLAB/Simulation in Power System. Research Journal of Recent Sciences, 1, 430-433.
[2]
Mokhtari, A., Gherbi, F.Z., Mokhtar, C., Kerrouche, K.D.E. and Aimer, A.F. (2014) Study, Analysis and Simulation of a Static Compensator D-STATCOM for Distribution Systems of Electric Power. Leonardo Journal of Sciences, No. 25, 117-130.
[3]
Rathore, K., Kumar, D. and Yadav, S. (2015) D-STATCOM Modeling and Simulation Applying Control Schemes for Power Quality Improvement. International Journal of Electronics and Telecommunication, 4, 27-36.
[4]
Amaris, H., Alons, M. and Ortega, C.A. (2013) Reactive Power Management of Power Networks with Wind Generation.
[5]
Kaur, N., Sharma, R. and Kaur, J. (2016) Analysing the Performance of D-Statcom in Mitigating Transients from Distribution System. International Journal of Engineering Research and Technology, 9, 17-28.
[6]
Eremia, M., Liu, C.-C. and Edris, A.-A. (2016) Advanced Solutions in Power Systems: HVDC, FACTS, and Artificial Intelligence, First Edition. The Institute of Electrical and Electronics Engineers, John Wiley & Sons.
[7]
Ledwich, G. and Ghosh, A. (2002) A Flexible DSTATCOM Operating in Voltage or Current Control Mode. IEEProceedings—Generation, TransmissionandDistribution, 149, 215. https://doi.org/10.1049/ip-gtd:20020009
[8]
Oloulade, A., Imano, A.M., Vianou, A. and Tamadaho, H. (2020) Optimisation Multi-critère du placement d’un D-STATCOM dans un réseau de Distribution par les Colonies de Fourmis. Symposium de Génie Electrique, hal 02983369.
[9]
Madhusudan, R. and Ramamohan Rao, G. (2012) Modeling and Simulation of a Distribution STATCOM (D-STATCOM) for Power Quality Problems-Voltage Sag and Swell Based on Sinusoidal Pulse Width Modulation (SPWM). IEEE-International Conference on Advances in Engineering, Science and Management (ICAESM-2012), Nagapattinam, 30-31 March 2012, 436-441.
[10]
Kumar, M., Swarnkar, A., Gupta, N. and Niazi, K.R. (2017) Design and Operation of DSTATCOM for Power Quality Improvement in Distribution Systems. TheJournalofEngineering, 2017, 2328-2333. https://doi.org/10.1049/joe.2017.0747
[11]
Gupta, G., Fritz, W. and Kahn, M.T.E. (2017) A Comprehensive Review of DSTATCOM: Control and Compensation Strategies. International Journal of Applied Engineering Research, 12, 3387-3393.
[12]
Chodavadiya, C., Kumar, V. and Parmar, B. (2012) Improve Voltage Profile of Power System Network using D-STATCOM and DVR with Matlab Simulation. International Journal of Engineering Research & Technology, 1, 1-6.
[13]
Ousseyni Ibrahim, H., Fifatin, F.X. and Oloulade, A. (2024) Study of the Dynamic Behavior of a DSTATCOM Installed in a Distribution Network in Case of Single and Multiphase Short Circuit. AdvancedEngineeringForum, 51, 49-60. https://doi.org/10.4028/p-39dswh
[14]
Lotfi, H., Samadi, M. and Dadpour, A. (2016) Optimal Capacitor Placement and Sizing in Radial Distribution System Using an Improved Particle Swarm Optimization Algorithm. 2016 21stConferenceonElectricalPowerDistributionNetworksConference (EPDC), Karaj, 26-27 April 2016, 147-152. https://doi.org/10.1109/epdc.2016.7514799
[15]
Djedili, C. and Ziane, F. (2020) Modeling and Control of a DSTATCOM Based on a Multilevel Converter. Master’s Thesis, Mohamed Boudiaf University.