The objective of this study is to determine the bacteriological parameters using the Petrifilm method for different water sources used in the urban municipality of Kankan. Sampling was carried out in July 2024 at nine sites according to the rate of exploitation by the local population. This study shows that the levels of pathogenic microorganisms such as fecal coliforms, total coliforms and E. coli in ordinary well water and the Milo River are well above the levels recommended by the WHO. The UJNK and CMIS boreholes show no pathology, while the Regional Hospital borehole revealed only the presence of E. coli. Overall, water samples from wells, taps, and boreholes at the various sampling sites are polluted according to WHO standards, with varying levels of pollution. This can be explained by the proximity of some sites to toilets but also by the fact that others are located in markets. The fountains installed in the Senkefara neighborhood showed no presence of CF and CT, but a number of E. coli greater than 100 populations/100mL. All of these results show that consuming this water without proper treatment exposes the population to serious health risks.
References
[1]
Aïssatou, B., & Balde, M. Y. (2024). Caractéristiques et qualité des eaux de forage de la commune de Ratoma. Revue Francophone, 2, 81-98.
[2]
Ba, S. (2018). Le péril de la pollution sur le fleuve Niger. L’Harmattan.
[3]
Baudart, J., & Paniel, N. (2014). Sources et devenir des micro-organismes pathogènes dans les environnements aquatiques. Revue Francophone des Laboratoires, 2014, 29-39. https://doi.org/10.1016/s1773-035x(14)72362-7
[4]
Bouteleux, C. (2005). Survie d’entérobactéries dans les eaux de distribution: Rôle de la matière organique d’origine algale. Sciences agricoles. Université Henri Poincaré.
[5]
Chippaux, J., Houssier, S., Gross, P., Bouvier, C., & Brissaud, F. (2002). Etude de la pollution de l’eau souterraine de la ville de Niamey. Bulletin de la Societe de Pathologie Exotique, 94, 119‑123.
[6]
Cissé, F. G. (2024). L’aire métropolitaine de Conakry: Les défis d’équipements et services collectifs au coeur des enjeux de recompositions sociospatiales de la capitale guinéenne. Géographie. Université Panthéon-Sorbonne.
[7]
Festy, B., Hartemann, P., Ledrans, M., Levallois, P., Payment, P., & Tricard, D. (2003). Qualité de l’eau. In Environnement et santé publique-Fondements et pratiques (pp. 333‑368). EHESP.
[8]
Géraldine, D. D. (2024). Les enjeux lies a l’eau potable son accessibilite, la perennisation des ressources en eau. Revue Européenne du Droit Social, 65, 139‑143.
[9]
Ghazali, D., & Zaid, A. (2013). Etude de la qualité physico-chimique et bactériologique des eaux de la source Ain Salama-Jerri (Région de Meknès-Maroc). Larhyss Journal, 12, 25-36.
[10]
Keita, A., Diallo, A., Tchanang, G., Goumou, K., Kanté, C., & Diakité, S. (2025). Evaluation of the Physico-Chemical Parameters of Water from Boreholes, Wells, Taps and the Milo River: Case of the Kankan Urban District. Journal of Water Resource and Protection, 17, 777-797. https://doi.org/10.4236/jwarp.2025.1711043
[11]
Konate, D., & Tiranké, K. (2024). Etat des lieux de la pisciculture dans la Commune Urbaine de Kankan. Revue Internationale de la Recherche Scientifique (Revue-IRS), 2, 352‑362.
[12]
Kpaibe, A. S., Guei, J. D., Ette, R. D., Gbagbo, A. T., Kouakou, J. S., & Amin, C. N. (2025). Évaluation de la perception des ménages sur qualité de l’eau d’adduction publique de la région du Gontougo (Côte d’Ivoire) en 2022. Afrique Science, 26, 150‑159.
[13]
Lawani, R., Kelome, N., Agassounon Djikpo Tchibozo, M., Hounkpe, J., & Adjagodo, A. (2017). Effets des pratiques agricoles sur la pollution des eaux de surface en République du Bénin. Larhyss Journal, 14, 173-190.
[14]
Mandjale, A. E. (1985). Mortalité infantile et juvénile en Afrique: Niveaux et caractéristiques, causes et déterminants. https://www.africabib.org/rec.php?RID=111976987
[15]
Minier, P. (2023). Assainir la ville sans contaminer l’environnement: Tout-à-l’égout et séparation à la source face au risque sanitaire lié aux matières fécales. Thèse de doctorat, École des Ponts ParisTech. https://pastel.hal.science/tel-04511281v1
[16]
Piton, C., & Rongvaux-Gaïda, D. (1990). Justesse de la technique des films secs réhydratables (Petrifilm SM et VRB) pour la numération des flores totale, psychrotrophe et coliforme du lait cru à l’usine. Le Lait, 70, 345-355. https://doi.org/10.1051/lait:1990426
[17]
Rath, S. (2021). Microbial Contamination of Drinking Water. In: Singh, A., Agrawal, M., Agrawal, S.B. (Eds.), Water Pollution and Management Practices, Springer. https://doi.org/10.1007/978-981-15-8358-2_1
[18]
Vissin, E. W., Aimade, H. S., Sohounou, M., Atiye, E. Y., Dougnon, L. D., & Atchade, G. A. (2016). Risques de pollution des eaux de surface dans la commune de Bassila, Bénin, Afrique de l’Ouest. Afrique Science, 12, 306‑314.
[19]
Zoungrana, T. D. (2021). Les déterminants du choix d’approvisionnement en eau potable des ménages ruraux de la commune de Koudougou au Burkina Faso. Économie rurale, 377, 65-81. https://doi.org/10.4000/economierurale.9135