全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Knowledge-Based Planning for Intensity-Modulated Proton Therapy for Patients with Locally Advanced Esophageal Cancer

DOI: 10.4236/ijmpcero.2026.151001, PP. 1-13

Keywords: Knowledge-Based Planning, IMPT, Esophageal, Overlap-Volume Histogram

Full-Text   Cite this paper   Add to My Lib

Abstract:

Purpose: To introduce a knowledge-based planning (KBP) framework for intensity-modulated proton therapy (IMPT) that generates patient-specific dose-volume histogram (DVH) objectives using a database of geometric and dosimetric data from previously treated esophageal cancer patients. Methods: The framework employs overlap-volume histogram (OVH) to quantify spatial relationship between organs at risk (OARs) and targets. For a new patient, OVH is calculated from DICOM CT and RT-structure and compared with those in a reference database to derive individualized DVH objectives for IMPT optimization. The reference database contains pre-calculated OVHs and DVH data for targets and OARs from previously clinically delivered plans. Eighteen patients with locally advanced esophageal cancer treated with IMPT were retrospectively analyzed. KBPs were created using a leave-one-out approach: DVH objectives for each KBP were generated from the remaining 17 patients and applied in the RayStation TPS for IMPT optimization. KBPs were compared with clinical plans (CPs: clinically delivered plans, manually created by planners) in target coverage and OAR sparing. Results: KBPs achieved comparable dosimetric quality to CPs in target coverage. OAR sparing was generally similar, with a significantly reduced spinal canal dose in KBPs. Conclusions: This study demonstrates the feasibility of an OVH-driven KBP framework for IMPT in esophageal cancer. By leveraging geometric-dosimetric correlations from prior patients, the method enables the automatic generation of individualized planning objectives, achieving plan quality comparable to clinical standards.

References

[1]  Ferlay, J., Steliarova-Foucher, E., Lortet-Tieulent, J., Rosso, S., Coebergh, J.W.W., Comber, H., et al. (2013) Cancer Incidence and Mortality Patterns in Europe: Estimates for 40 Countries in 2012. European Journal of Cancer, 49, 1374-1403.
https://doi.org/10.1016/j.ejca.2012.12.027
[2]  Castro, C., Bosetti, C., Malvezzi, M., Bertuccio, P., Levi, F., Negri, E., et al. (2014) Patterns and Trends in Esophageal Cancer Mortality and Incidence in Europe (1980-2011) and Predictions to 2015. Annals of Oncology, 25, 283-290.
https://doi.org/10.1093/annonc/mdt486
[3]  Obermannová, R., Alsina, M., Cervantes, A., Leong, T., Lordick, F., Nilsson, M., et al. (2022) Oesophageal Cancer: ESMO Clinical Practice Guideline for Diagnosis, Treatment and Follow-Up. Annals of Oncology, 33, 992-1004.
https://doi.org/10.1016/j.annonc.2022.07.003
[4]  Hoeppner, J., Lordick, F., Brunner, T., Glatz, T., Bronsert, P., Röthling, N., et al. (2016) ESOPEC: Prospective Randomized Controlled Multicenter Phase III Trial Comparing Perioperative Chemotherapy (FLOT Protocol) to Neoadjuvant Chemoradiation (CROSS Protocol) in Patients with Adenocarcinoma of the Esophagus (NCT02509286). BMC Cancer, 16, Article No. 503.
https://doi.org/10.1186/s12885-016-2564-y
[5]  Reynolds, J.V., Preston, S.R., O’Neill, B., Baeksgaard, L., Griffin, S.M., et al. (2017) ICORG 10-14: NEOadjuvant Trial in Adenocarcinoma of the oEsophagus and oesophagoGastric Junction International Study (Neo-AEGIS). BMC Cancer, 17, Article No. 401.
[6]  Xu, D., Li, G., Li, H. and Jia, F. (2017) Comparison of IMRT versus 3D-CRT in the Treatment of Esophagus Cancer: A Systematic Review and Meta-Analysis. Medicine, 96, e7685.
https://doi.org/10.1097/md.0000000000007685
[7]  Xi, M. and Lin, S.H. (2017) Recent Advances in Intensity Modulated Radiotherapy and Proton Therapy for Esophageal Cancer. Expert Review of Anticancer Therapy, 17, 635-646.
https://doi.org/10.1080/14737140.2017.1331130
[8]  Hirano, Y., Onozawa, M., Hojo, H., Motegi, A., Zenda, S., Hotta, K., et al. (2018) Dosimetric Comparison between Proton Beam Therapy and Photon Radiation Therapy for Locally Advanced Esophageal Squamous Cell Carcinoma. Radiation Oncology, 13, Article No. 23.
https://doi.org/10.1186/s13014-018-0966-5
[9]  Warren, S., Partridge, M., Bolsi, A., Lomax, A.J., Hurt, C., Crosby, T., et al. (2016) An Analysis of Plan Robustness for Esophageal Tumors: Comparing Volumetric Modulated Arc Therapy Plans and Spot Scanning Proton Planning. International Journal of Radiation Oncology, Biology, Physics, 95, 199-207.
https://doi.org/10.1016/j.ijrobp.2016.01.044
[10]  Liu, C., Bhangoo, R.S., Sio, T.T., Yu, N.Y., Shan, J., Chiang, J.S., et al. (2019) Dosimetric Comparison of Distal Esophageal Carcinoma Plans for Patients Treated with Small-Spot Intensity-Modulated Proton versus Volumetric-Modulated Arc Therapies. Journal of Applied Clinical Medical Physics, 20, 15-27.
https://doi.org/10.1002/acm2.12623
[11]  Xi, M., Xu, C., Liao, Z., Chang, J.Y., Gomez, D.R., Jeter, M., et al. (2017) Comparative Outcomes after Definitive Chemoradiotherapy Using Proton Beam Therapy versus Intensity Modulated Radiation Therapy for Esophageal Cancer: A Retrospective, Single-Institutional Analysis. International Journal of Radiation Oncology, Biology, Physics, 99, 667-676.
https://doi.org/10.1016/j.ijrobp.2017.06.2450
[12]  Warren, S., Hurt, C.N., Crosby, T., Partridge, M. and Hawkins, M.A. (2017) Potential of Proton Therapy to Reduce Acute Hematologic Toxicity in Concurrent Chemoradiation Therapy for Esophageal Cancer. International Journal of Radiation Oncology, Biology, Physics, 99, 729-737.
https://doi.org/10.1016/j.ijrobp.2017.07.025
[13]  Hirano, Y., Onozawa, M., Hojo, H., Motegi, A., Zenda, S., Hotta, K., et al. (2018) Dosimetric Comparison between Proton Beam Therapy and Photon Radiation Therapy for Locally Advanced Esophageal Squamous Cell Carcinoma. Radiation Oncology, 13, Article No. 23.
https://doi.org/10.1186/s13014-018-0966-5
[14]  Wu, A.J., Bosch, W.R., Chang, D.T., Hong, T.S., Jabbour, S.K., Kleinberg, L.R., et al. (2015) Expert Consensus Contouring Guidelines for Intensity Modulated Radiation Therapy in Esophageal and Gastroesophageal Junction Cancer. International Journal of Radiation Oncology, Biology, Physics, 92, 911-920.
https://doi.org/10.1016/j.ijrobp.2015.03.030
[15]  Celik, E., Baues, C., Claus, K., Fogliata, A., Scorsetti, M., Marnitz, S., et al. (2021) Knowledge-Based Intensity-Modulated Proton Planning for Gastroesophageal Carcinoma. Acta Oncologica, 60, 285-292.
https://doi.org/10.1080/0284186x.2020.1845396
[16]  Wu, B., McNutt, T., Zahurak, M., Simari, P., Pang, D., Taylor, R., et al. (2012) Fully Automated Simultaneous Integrated Boosted–intensity Modulated Radiation Therapy Treatment Planning Is Feasible for Head-and-Neck Cancer: A Prospective Clinical Study. International Journal of Radiation Oncology, Biology, Physics, 84, e647-e653.
https://doi.org/10.1016/j.ijrobp.2012.06.047
[17]  Wu, B., Ricchetti, F., Sanguineti, G., Kazhdan, M., Simari, P., Chuang, M., et al. (2009) Patient Geometry-Driven Information Retrieval for IMRT Treatment Plan Quality Control. Medical Physics, 36, 5497-5505.
https://doi.org/10.1118/1.3253464
[18]  Wu, B., Ricchetti, F., Sanguineti, G., Kazhdan, M., Simari, P., Jacques, R., et al. (2011) Data-Driven Approach to Generating Achievable Dose-Volume Histogram Objectives in Intensity-Modulated Radiotherapy Planning. International Journal of Radiation Oncology, Biology, Physics, 79, 1241-1247.
https://doi.org/10.1016/j.ijrobp.2010.05.026
[19]  Wu, B., Pang, D., Simari, P., Taylor, R., Sanguineti, G. and McNutt, T. (2013) Using Overlap Volume Histogram and IMRT Plan Data to Guide and Automate VMAT Planning: A Head-and-Neck Case Study. Medical Physics, 40, Article 021714.
https://doi.org/10.1118/1.4788671
[20]  Wu, B., Pang, D., Lei, S., Gatti, J., Tong, M., McNutt, T., et al. (2014) Improved Robotic Stereotactic Body Radiation Therapy Plan Quality and Planning Efficacy for Organ-Confined Prostate Cancer Utilizing Overlap-Volume Histogram-Driven Planning Methodology. Radiotherapy and Oncology, 112, 221-226.
https://doi.org/10.1016/j.radonc.2014.07.009
[21]  Lin, S.H., Hobbs, B.P., Verma, V., Tidwell, R.S., Smith, G.L., Lei, X., et al. (2020) Randomized Phase IIB Trial of Proton Beam Therapy versus Intensity-Modulated Radiation Therapy for Locally Advanced Esophageal Cancer. Journal of Clinical Oncology, 38, 1569-1579.
https://doi.org/10.1200/jco.19.02503
[22]  Hall, D.C., Trofimov, A.V., Winey, B.A., Liebsch, N.J. and Paganetti, H. (2017) Predicting Patient-Specific Dosimetric Benefits of Proton Therapy for Skull-Base Tumors Using a Geometric Knowledge-Based Method. International Journal of Radiation Oncology, Biology, Physics, 97, 1087-1094.
https://doi.org/10.1016/j.ijrobp.2017.01.236
[23]  Smulders, B., Stolarczyk, L., Seiersen, K., Nørrevang, O., Sommer Kristensen, B., Schut, D.A., et al. (2023) Prediction of Dose-Sparing by Protons Assessed by a Knowledge-Based Planning Tool in Radiotherapy of Brain Tumours. Acta Oncologica, 62, 1541-1545.
https://doi.org/10.1080/0284186x.2023.2264482
[24]  Forsthoefel, M.K., Ballew, E., Unger, K.R., Ahn, P.H., Rudra, S., Pang, D., et al. (2020) Early Experience of the First Single-Room Gantry Mounted Active Scanning Proton Therapy System at an Integrated Cancer Center. Frontiers in Oncology, 10, Article 861.
https://doi.org/10.3389/fonc.2020.00861
[25]  Kang, M. and Pang, D. (2020) Commissioning and Beam Characterization of the First Gantry-Mounted Accelerator Pencil Beam Scanning Proton System. Medical Physics, 47, 3496-3510.
https://doi.org/10.1002/mp.13972
[26]  Gutierrez, A., Rompokos, V., Li, K., Gillies, C., D’Souza, D., Solda, F., et al. (2019) The Impact of Proton LET/RBE Modeling and Robustness Analysis on Base-of-Skull and Pediatric Craniopharyngioma Proton Plans Relative to VMAT. Acta Oncologica, 58, 1765-1774.
https://doi.org/10.1080/0284186x.2019.1653496

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133