Chlorine Dioxide as an Effective Agent for Bioaerosol Mitigation in Critical Facilities

DOI: 10.4236/odem.2026.141001, PP. 1-7

Keywords: Chlorine Dioxide, Bioaerosol Mitigation, Critical Facilities, Antimicrobial Efficacy

Full-Text   Cite this paper   Add to My Lib

Abstract:

Chlorine dioxide (ClO2) gas is a well-established antimicrobial agent with broad-spectrum efficacy against bacteria, fungi, and viruses. In clinical settings, especially operating rooms and dental clinics, bioaerosol transmission of infectious agents poses significant risks. This study evaluates the effectiveness of ClO2 gas in mitigating airborne microbial contaminants using data from experimental setups, including HEPA filter environments, chlorine dioxide filters, and controlled laboratory conditions. Supported by empirical findings and our previously published studies, this study’s results demonstrate over 99% reduction in airborne pathogens, confirming ClO2’s potential as a critical disinfection strategy in healthcare facilities.

References

[1]  Allison, J.R., Tiede, S., Holliday, R., Durham, J. and Jakubovics, N.S. (2024) Bioaerosols and Airborne Transmission in the Dental Clinic. International Dental Journal, 74, S418-S428.
https://doi.org/10.1016/j.identj.2024.09.026
[2]  Janczarek, M., Ślosarczyk, A., Klapiszewska, I., Riha, J., Jesionowski, T. and Klapiszewski, Ł. (2024) Airborne Bioaerosols in Healthcare Facilities—Transmission Routes and Mitigation Strategies. A Review. Journal of Building Engineering, 97, Article ID: 111015.
https://doi.org/10.1016/j.jobe.2024.111015
[3]  Polednik, B. (2021) Exposure of Staff to Aerosols and Bioaerosols in a Dental Office. Building and Environment, 187, Article ID: 107388.
https://doi.org/10.1016/j.buildenv.2020.107388
[4]  Persoons, R., Parat, S., Stoklov, M., Perdrix, A. and Maitre, A. (2010) Critical Working Tasks and Determinants of Exposure to Bioaerosols and MVOC at Composting Facilities. International Journal of Hygiene and Environmental Health, 213, 338-347.
https://doi.org/10.1016/j.ijheh.2010.06.001
[5]  Chen, T., Chen, Y., Zhao, Y. and Chiang, P. (2020) Application of Gaseous ClO2 on Disinfection and Air Pollution Control: A Mini Review. Aerosol and Air Quality Research, 20, 2289-2298.
https://doi.org/10.4209/aaqr.2020.06.0330
[6]  Yue, C., Yuya, H., Zhihuan, L., Zimo, W. and Jianying, F. (2024) Study on the Disinfection Effect of Chlorine Dioxide Disinfectant (ClO2) on Dental Unit Waterlines and Its in Vitro Safety Evaluation. BMC Oral Health, 24, Article No. 648.
https://doi.org/10.1186/s12903-024-04391-7
[7]  Burton, N.C., Adhikari, A., Iossifova, Y., Grinshpun, S.A. and Reponen, T. (2008) Effect of Gaseous Chlorine Dioxide on Indoor Microbial Contaminants. Journal of the Air & Waste Management Association, 58, 647-656.
https://doi.org/10.3155/1047-3289.58.5.647
[8]  Driver, J., Lukasik, G., Bourgeois, M., Tam, P. and Harbison, R. (2021) Virucidal Activity of Chlorine Dioxide Gas for Reduction of Coronavirus on Surfaces and PPE. Occupational Diseases and Environmental Medicine, 9, 13-19.
https://doi.org/10.4236/odem.2021.91002
[9]  Driver, J., Lichterman, J., Lukasik, G., Jones, S., Bourgeois, M. and Harbison, R. (2022) Bactericidal and Fungicidal Efficacy of Chlorine Dioxide in Various Workspaces. Occupational Diseases and Environmental Medicine, 10, 49-59.
https://doi.org/10.4236/odem.2022.102004
[10]  CDC (2012) NIOSH Pocket Guide to Chemical Hazards.
https://www.cdc.gov/niosh/docs/2013-102/pdfs/2013-102.pdf
[11]  Occupational Safety and Health Administration (OSHA) (2006) Preventing Mold-Related Problems in the Indoor Workplace.
https://www.osha.gov/sites/default/files/publications/preventing_mold.pdf
[12]  Hsu, C., Lu, M. and Huang, D. (2013) Effect of Gaseous Chlorine Dioxide on Student Cafeteria Bioaerosols. CLEAN—Soil, Air, Water, 42, 12-19.
https://doi.org/10.1002/clen.201100293

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133