Optimizing LINAC-Based Stereotactic Radiosurgery Dosimetric Outcomes as Dictated by Beam Energy, Multileaf Collimator Size, and Prescribed Isodose Level

DOI: 10.4236/ijmpcero.2025.144012, PP. 147-160

Keywords: SRS, DCA, MLC

Full-Text   Cite this paper   Add to My Lib

Abstract:

Background and Purpose: Radiation therapy is one of the methods for the treatment of brain tumors. Besides using Co-60-based radiation, LINAC-based stereotactic radiosurgery (SRS) has been widely used in the treatment of intracranial tumors. This study aims to compare the dosimetric outcomes of different SRS methods for typical brain tumors of various sizes, as dictated by beam energy, MLC leaf width, and prescribed isodose level (IDL) using the dynamic conformal arc. Methods: Hypothetical target lesions of 4 different sizes were contoured on the brain MRI images of an index patient. The PTVs were constructed to fall within four respective categories (<0.5, 0.5 - 1.0, 1.0 - 4.0, 4.0 - 10.0 cc), in inverse proportion to the prescription dose range of 16 - 22.5 Gy. For each lesion, SRS plans were analyzed independently between: 1) two photon beam energies with different dose rates (6X-FFF with 1400 MU/min vs. 10X-FFF with 2400 MU/min); 2) two MLC leaf widths (0.5 cm vs. 0.25 cm); and 3) two different prescribed isodose lines (90% IDL vs. 80% IDL). The degree of normal tissue sparing was evaluated by the amount of brain volume receiving more than 12 Gy (V12) and the dose Gradient Index (GI), defined as the ratio between the volume receiving more than 50% of the prescribed dose (V50%) and the PTV volume. Tumor dose inhomogeneity was analyzed in relation to the maximum dose (Dmax) deposited, while conformity was assessed using the Conformity Index (CI), defined as the ratio of the V100% volume to the PTV volume. Treatment beam-on time was also compared. All three independent variables (beam energy, MLC leaf width, and prescribed IDL) were held constant, except for the one being analyzed, with mean relative differences in the dosimetric outcomes determined for all four lesions of respective volumes. Results: The 4 PTV volumes contoured were: 0.35, 0.68, 1.76, and 5.60 cc, respectively. Dmax was affected only by the prescribed IDL, while the tumor CI did not exhibit any significant difference for all 3 variables analyzed. Compared to a beam energy of 6X FFF, the 10X FFF plans were found to have a GI and V12 that were both increased by about 13% and 14%, respectively. However, the higher beam energy resulted in a shorter beam-on time by approximately 49%. Compared to 0.25 cm MLC leaf-width, the 0.5 cm plans have higher GI by 22.12% ± 8.64%, higher V12 by 22.20% ± 11.12%, and shorter beam-on time by 2.63% ± 1.07%. Compared to 80% IDL, the 90% IDL

References

[1]  Porter, K.R., McCarthy, B.J., Freels, S., Kim, Y. and Davis, F.G. (2010) Prevalence Estimates for Primary Brain Tumors in the United States by Age, Gender, Behavior, and Histology. Neuro-Oncology, 12, 520-527.
https://doi.org/10.1093/neuonc/nop066
[2]  Siegel, R.L., Miller, K.D., Wagle, N.S. and Jemal, A. (2023) Cancer Statistics, 2023. CA: A Cancer Journal for Clinicians, 73, 17-48.
https://doi.org/10.3322/caac.21763
[3]  https://braintumor.org/brain-tumors/about-brain-tumors/brain-tumor-facts/
[4]  https://seer.cancer.gov/statfacts/html/brain.html
[5]  Sperduto, P.W., Mesko, S., Li, J., Cagney, D., Aizer, A., Lin, N.U., et al. (2020) Survival in Patients with Brain Metastases: Summary Report on the Updated Diagnosis-Specific Graded Prognostic Assessment and Definition of the Eligibility Quotient. Journal of Clinical Oncology, 38, 3773-3784.
https://doi.org/10.1200/jco.20.01255
[6]  Patchell, R.A., Tibbs, P.A., Regine, W.F., Dempsey, R.J., Mohiuddin, M., Kryscio, R.J., et al. (1998) Postoperative Radiotherapy in the Treatment of Single Metastases to the Brain. JAMA, 280, 1485-1489.
https://doi.org/10.1001/jama.280.17.1485
[7]  Aoyama, H., Shirato, H., Tago, M., Nakagawa, K., Toyoda, T., Hatano, K., et al. (2006) Stereotactic Radiosurgery Plus Whole-Brain Radiation Therapy vs. Stereotactic Radiosurgery Alone for Treatment of Brain Metastases. JAMA, 295, 2483-2491.
https://doi.org/10.1001/jama.295.21.2483
[8]  Gondi, V., Pugh, S.L., Tome, W.A., Caine, C., Corn, B., Kanner, A., et al. (2014) Preservation of Memory with Conformal Avoidance of the Hippocampal Neural Stem-Cell Compartment during Whole-Brain Radiotherapy for Brain Metastases (RTOG 0933): A Phase II Multi-Institutional Trial. Journal of Clinical Oncology, 32, 3810-3816.
https://doi.org/10.1200/jco.2014.57.2909
[9]  Brown, P.D., Ballman, K.V., Cerhan, J.H., Anderson, S.K., Carrero, X.W., Whitton, A.C., et al. (2017) Postoperative Stereotactic Radiosurgery Compared with Whole Brain Radiotherapy for Resected Metastatic Brain Disease (NCCTG N107C/CEC·3): A Multicentre, Randomised, Controlled, Phase 3 Trial. The Lancet Oncology, 18, 1049-1060.
https://doi.org/10.1016/s1470-2045(17)30441-2
[10]  Hartgerink, D., Swinnen, A., Roberge, D., Nichol, A., Zygmanski, P., Yin, F., et al. (2019) LINAC Based Stereotactic Radiosurgery for Multiple Brain Metastases: Guidance for Clinical Implementation. Acta Oncologica, 58, 1275-1282.
https://doi.org/10.1080/0284186x.2019.1633016
[11]  Dhabaan, A., Elder, E., Schreibmann, E., Crocker, I., Curran, W.J., Oyesiku, N.M., et al. (2010) Dosimetric Performance of the New High‐Definition Multileaf Collimator for Intracranial Stereotactic Radiosurgery. Journal of Applied Clinical Medical Physics, 11, 197-211.
https://doi.org/10.1120/jacmp.v11i3.3040
[12]  Monk, J.E., Perks, J.R., Doughty, D. and Plowman, P.N. (2003) Comparison of a Micro-Multileaf Collimator with a 5-Mm-Leaf-Width Collimator for Intracranial Stereotactic Radiotherapy. International Journal of Radiation Oncology Biology Physics, 57, 1443-1449.
https://doi.org/10.1016/s0360-3016(03)01579-7
[13]  Chern, S., Leavitt, D.D., Jensen, R.L. and Shrieve, D.C. (2006) Is Smaller Better? Comparison of 3-Mm and 5-Mm Leaf Size for Stereotactic Radiosurgery: A Dosimetric Study. International Journal of Radiation Oncology Biology Physics, 66, S76-S81.
https://doi.org/10.1016/j.ijrobp.2006.04.061
[14]  Zhao, B., et al. (2014) Prescription to 50-75% Isodose Line May be Optimum for Linear Accelerator Based Radiosurgery of Cranial Lesions. Journal of Radiosurgery and Stereotactic Body Radiation Therapy, 3, 139-147.
[15]  Zhang, Q., Zheng, D., Lei, Y., Morgan, B., Driewer, J., Zhang, M., et al. (2014) A New Variable for SRS Plan Quality Evaluation Based on Normal Tissue Sparing: The Effect of Prescription Isodose Levels. The British Journal of Radiology, 87, Article 20140362.
https://doi.org/10.1259/bjr.20140362
[16]  Laoui, S., et al. (2020) Flattening Filter Free Beam Energy Selection and Its Impact in Multi-Target Intracranial Stereotactic Radiosurgery Treatments. Medical Dosimetry, 45, 363-367.
[17]  Lee, B., Zhang, J.Y., Quang, T., Lien, W., Kwon, R. and Lee, S. (2023) Dosimetric Optimization in LINAC-Based Stereotactic Radiosurgery via Dynamic Conformal Arcs & High-Definition MLCs for Multiple Targets in Geographic Proximity. The Brainlab Novalis Circle 9th International Conference, Munich, 15-16 September 2023.
[18]  Blonigen, B.J., Steinmetz, R.D., Levin, L., Lamba, M.A., Warnick, R.E. and Breneman, J.C. (2010) Irradiated Volume as a Predictor of Brain Radionecrosis after Linear Accelerator Stereotactic Radiosurgery. International Journal of Radiation Oncology*Biology*Physics, 77, 996-1001.
https://doi.org/10.1016/j.ijrobp.2009.06.006
[19]  Wang, C., Lin, Y., Tseng, H., Xiao, F., Chen, C., Cheng, W., et al. (2015) Prolonged Treatment Time Deteriorates Positioning Accuracy for Stereotactic Radiosurgery. PLOS ONE, 10, e0123359.
https://doi.org/10.1371/journal.pone.0123359
[20]  Jung, H., Yoon, J., Dona Lemus, O., Tanny, S., Zhou, Y., Milano, M., et al. (2024) Dosimetric Evaluation of Linac-Based Single-Isocenter Multi-Target Multi-Fraction Stereotactic Radiosurgery with More than 20 Targets: Comparing MME, Hyperarc, and Rapidarc. Radiation Oncology, 19, Article No. 19.
https://doi.org/10.1186/s13014-024-02416-7

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133