全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Impact of the Non-Negativity Constraint for In-Line Phase Contrast Computed Tomography

DOI: 10.4236/jsip.2025.164005, PP. 58-69

Keywords: Non-Negativity Constraint, IL-PCCT, X-Ray

Full-Text   Cite this paper   Add to My Lib

Abstract:

In-line X-ray phase-contrast computed tomography (IL-PCCT) can reconstruct high resolution images, and the core of IL-PCCT is the image reconstruction algorithm. As we all know, image reconstruction algorithm can suppress artifacts and produce high-quality reconstructed images using a priori constraint information. For conventional absorption X-ray CT, a common constraint is that linear attenuation coefficient has to be positive, as a negative value is physically not possible. Using the non-negative values priori information is believed to be beneficial in terms of image quality and convergence speed. Phase retrieval is a key step in achieving IL-PCCT. Due to considerations such as radiation dose, single-distance phase retrieval is typically employed. However, single-distance phase retrieval relies on limited data, and especially when the data is insufficient, it may lead to inaccurate reconstruction results. If they exceed the expected range or do not match the physical characteristics of the sample, they generally indicate errors in the retrieval process. In the image reconstruction process, when using projection data obtained from single-distance phase retrieval, whether to introduce a non-negative constraint as a regularization condition is a question worth exploring, but its validity has not yet been systematically studied. In this work, we present an investigation into this problem. The investigation is divided into various experimental studies that non-negativity constraint effect on the IL-PCCT.

References

[1]  Coan, P., Bamberg, F., Diemoz, P.C., Bravin, A., Timpert, K., Mützel, E., et al. (2010) Characterization of Osteoarthritic and Normal Human Patella Cartilage by Computed Tomography X-Ray Phase-Contrast Imaging. Investigative Radiology, 45, 437-444.
https://doi.org/10.1097/rli.0b013e3181e193bd
[2]  Snigirev, A., Snigireva, I., Kohn, V., Kuznetsov, S. and Schelokov, I. (1995) On the Possibilities of X-Ray Phase Contrast Microimaging by Coherent High-Energy Synchrotron Radiation. Review of Scientific Instruments, 66, 5486-5492.
https://doi.org/10.1063/1.1146073
[3]  Davis, T.J., Gao, D., Gureyev, T.E., Stevenson, A.W. and Wilkins, S.W. (1995) Phase-contrast Imaging of Weakly Absorbing Materials Using Hard X-Rays. Nature, 373, 595-598.
https://doi.org/10.1038/373595a0
[4]  Momose, A. (2020) X-Ray Phase Imaging Reaching Clinical Uses. Physica Medica, 79, 93-102.
https://doi.org/10.1016/j.ejmp.2020.11.003
[5]  Kak, A.C. and Slaney, M. (2001) Principles of Computerized Tomographic Imaging. Society for Industrial and Applied Mathematics.
https://doi.org/10.1137/1.9780898719277
[6]  Hounsfifield, G.N. (1972) A Method and Apparatus for Examination of a Body by Radiation Such as X-Ray or γ Radiation. Patent Specifification 1283915.
[7]  Gordon, R., Bender, R. and Herman, G.T. (1970) Algebraic Reconstruction Techniques (ART) for Three-Dimensional Electron Microscopy and X-Ray Photography. Journal of Theoretical Biology, 29, 471-481.
https://doi.org/10.1016/0022-5193(70)90109-8
[8]  Sidky, E.Y., Kao, C. and Pan, X. (2006) Accurate Image Reconstruction from Few-Views and Limited-Angle Data in Divergent-Beam Ct. Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics, 14, 119-139.
https://doi.org/10.3233/xst-2006-00155
[9]  Sidky, E.Y. and Pan, X. (2008) Image Reconstruction in Circular Cone-Beam Computed Tomography by Constrained, Total-Variation Minimization. Physics in Medicine and Biology, 53, 4777-4807.
https://doi.org/10.1088/0031-9155/53/17/021
[10]  Rudin, L.I., Osher, S. and Fatemi, E. (1992) Nonlinear Total Variation Based Noise Removal Algorithms. Physica D: Nonlinear Phenomena, 60, 259-268.
https://doi.org/10.1016/0167-2789(92)90242-f
[11]  Cai, J., Dong, B., Osher, S. and Shen, Z. (2012) Image Restoration: Total Variation, Wavelet Frames, and Beyond. Journal of the American Mathematical Society, 25, 1033-1089.
https://doi.org/10.1090/s0894-0347-2012-00740-1
[12]  Bui, K., Park, F., Lou, Y. and Xin, J. (2021) A Weighted Difference of Anisotropic and Isotropic Total Variation for Relaxed Mumford—Shah Color and Multiphase Image Segmentation. SIAM Journal on Imaging Sciences, 14, 1078-1113.
https://doi.org/10.1137/20m1337041
[13]  Ji, D., Qu, G., Hu, C., Liu, B., Jian, J. and Guo, X. (2017) Anisotropic Total Variation Minimization Approach in In-Line Phase-Contrast Tomography and Its Application to Correction of Ring Artifacts. Chinese Physics B, 26, Article ID: 060701.
https://doi.org/10.1088/1674-1056/26/6/060701
[14]  Barrett, R., Berry, M., Chan, T.F., Demmel, J., Donato, J., Dongarra, J., et al. (1994) Templates for the Solution of Linear Systems: Building Blocks for Iterative Methods. Society for Industrial and Applied Mathematics.
https://doi.org/10.1137/1.9781611971538
[15]  Wang, Z., Bovik, A.C., Sheikh, H.R. and Simoncelli, E.P. (2004) Image Quality Assessment: From Error Visibility to Structural Similarity. IEEE Transactions on Image Processing, 13, 600-612.
https://doi.org/10.1109/tip.2003.819861
[16]  Gonzalez, R.C. and Woods, R.E. (2017) Digital Image Processing. 4th Edition, Electronic Industry Press., 368-393.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133