Pulsatile Flow Hemodynamics in a Stenosed Artery for Newtonian and Non-Newtonian Rheological Models

DOI: 10.4236/ojmsi.2025.134010, PP. 185-195

Keywords: Pulsatile Flow, Stenosis, Hemodynamics, Recirculation, Non-Newtonian Rheological Model

Full-Text   Cite this paper   Add to My Lib

Abstract:

Atheromatous disease can cause a heart attack or stroke in humans. This present research aims to investigate the comparison between Newtonian and rheological models in terms of hemodynamic risk factors. A three-dimensional computational model has been considered here for 45%, 60%, and 75% stenoses. The COMSOL Multiphysics software has been used in fluid flow simulation to solve the governing equations. The comparison between Newtonian and non-Newtonian has been performed to predict the model’s suitability. Hemodynamic parameters such as time-averaged wall shear stress (TAWSS), oscillatory shearing index, and blood residence time show a lower disturbed flow regime for non-Newtonian fluid compared to Newtonian fluid. The TAWSS for 75% stenosis is increased by 54.84% and 37.18% to those of 45% and 60% stenoses. A suitable non-Newtonian model can be used in bioengineering fields.

References

[1]  Akbar, S. and Shah, S.R. (2024) Mathematical Modeling of Blood Flow Dynamics in the Cardiovascular System: Assumptions, Considerations, and Simulation Results. Journal of Current Medical Research and Opinion, 7, 2216-2225.
[2]  Anamika Shah, S.R. and Singh, A. (2017) Mathematical and Computational Study of Blood Flow through Diseased Artery. International Journal of Computer Science, 5, 1-6.
[3]  Dutt, M.G., Shah, S.R. and Arya, S. (2024) Optimizing Cardiovascular Health: Ayurvedic Insights into Blood Flow through Normal and Stenosed Arteries. International Journal of AYUSH, 13, 18-35.
[4]  Udupa, M.C., Saha, S. and Natarajan, S. (2025) Study of Blood Flow Patterns in a Stenosed Artery through the Combined Effect of Body Acceleration and Generalized Womersley Solution. Scientific Reports, 15, Article No. 1845.
https://doi.org/10.1038/s41598-025-85566-2
[5]  Shah, S.R., Siddiqui, S.U. and Singh, A. (2015) Mathematical Modelling and Analysis of Blood Flow through Diseased Blood Vessels. International Journal of Engineering and Management Research, 5, 366-372.
[6]  Singh, S. and Shah, R.R. (2010) A Numerical Model for the Effect of Stenosis Shape on Blood Flow through an Artery Using Power-Law Fluid. Advance in Applied Science Research, 1, 66-73.
[7]  Shah, S.R. and Kumar, R. (2017) A Mathematical Approach to Study the Blood Flow through Tapered Stenosed Artery with the Suspension of Nanoparticles. DEStech Transactions on Engineering and Technology Research, 1, 1-6.
https://doi.org/10.12783/dtetr/amsm2017/14809
[8]  Shah, S.R. (2013) A Mathematical Model for the Analysis of Blood Flow through Diseased Blood Vessels under the Influence of Porous Parameter. Journal of Biosciences and Technology, 4, 534-541.
[9]  Singh, A. and Shah, S.R. (2024) Influence of Transverse Magnetic Field on Steady Blood Flow in a Stenosed Artery: Numerical and Analytical Insights. International Journal of Mathematical Archive, 15, 1-10.
[10]  Kumar, V. and Shah, S.R. (2022) A Mathematical Study for Heat Transfer Phenomenological Processes in Human Skin. International Journal of Mechanical Engineering, 7, 683-692.
[11]  Sapna, K. and Siddiqui, S.U. (2004) Study of Blood Flow through a Stenosed Capillary Using Casson’s Fluid Model. Ultra Science: International Journal of Physical Sciences, 16, 133-142.
[12]  Sapna, S. (2009) Analysis of Non-Newtonian Fluid Flow in a Stenosed Artery. Inter-national Journal of Physical Sciences, 4, 663-671.
[13]  Wu, H., Wang, H., Wang, H., Zhang, Y. and Guo, L. (2025) Numerical Simulation of Flow and Heat Transfer Characteristics in the Extrusion and Stretching Process of Non-Newtonian Fluid in Microchannel. Chemical Engineering Science, 306, Article ID: 121252.
https://doi.org/10.1016/j.ces.2025.121252
[14]  Wajihah, S.A. and Sankar, D.S. (2023) A Review on Non-Newtonian Fluid Models for Multi-Layered Blood Rheology in Constricted Arteries. Archive of Applied Mechanics, 93, 1771-1796.
https://doi.org/10.1007/s00419-023-02368-6
[15]  Eberhard, U., Seybold, H.J., Secchi, E., Jiménez-Martínez, J., Rühs, P.A., Ofner, A., et al. (2020) Mapping the Local Viscosity of Non-Newtonian Fluids Flowing through Disordered Porous Structures. Scientific Reports, 10, Article No. 11733.
https://doi.org/10.1038/s41598-020-68545-7
[16]  Nader, E., Skinner, S., Romana, M., Fort, R., Lemonne, N., Guillot, N., et al. (2019) Blood Rheology: Key Parameters, Impact on Blood Flow, Role in Sickle Cell Disease and Effects of Exercise. Frontiers in Physiology, 10, Article 1329.
https://doi.org/10.3389/fphys.2019.01329
[17]  Wang, S., Wu, D., Li, G., Zhang, Z., Xiao, W., Li, R., et al. (2023) Deep Learning-Based Hemodynamic Prediction of Carotid Artery Stenosis before and after Surgical Treatments. Frontiers in Physiology, 13, Article 1094743.
https://doi.org/10.3389/fphys.2022.1094743
[18]  Rahman, M.M., Hossain, M.A., Mamun, K. and Akhter, M.N. (2018) Comparative Study of Newtonian and Non-Newtonian Blood Flow through a Stenosed Carotid Artery. AIP Conference Proceedings, 1980, Article ID: 040017.
https://doi.org/10.1063/1.5044327
[19]  Liu, H., Lan, L., Abrigo, J., Ip, H.L., Soo, Y., Zheng, D., et al. (2021) Comparison of Newtonian and Non-Newtonian Fluid Models in Blood Flow Simulation in Patients with Intracranial Arterial Stenosis. Frontiers in Physiology, 12, Article 718540.
https://doi.org/10.3389/fphys.2021.718540
[20]  Wong, K.K.L., Wu, J., Liu, G., Huang, W. and Ghista, D.N. (2020) Coronary Arteries Hemodynamics: Effect of Arterial Geometry on Hemodynamic Parameters Causing Atherosclerosis. Medical & Biological Engineering & Computing, 58, 1831-1843.
https://doi.org/10.1007/s11517-020-02185-x
[21]  Kumar, J.P., Sadique, M. and Shah, S.R. (2022) Mathematical Study of Blood Flow through Blood Vessels under Diseased Condition. International Journal of Multidisciplinary Research and Development, 9, 31-44.
[22]  Kumar, A. and Shah, S.R. (2024) Hemodynamic Simulation Approach to Understanding Blood Flow Dynamics in Stenotic Arteries. International Journal of Scientific Research in Science and Technology, 11, 630-636.
https://doi.org/10.32628/ijsrst241161116
[23]  Akbar, S., Sharma, R.K., Sadique, M., Jaiswal, K.M., Chaturvedi, P., Kumar, V., et al. (2024) Computational Analysis of Clot Formation Risk in Diabetes: A Mathematical Modeling Approach. Bibechana, 21, 233-240.
https://doi.org/10.3126/bibechana.v21i3.64973
[24]  Chaturvedi, P. and Shah, S.R. (2023) Mathematical Analysis for the Flow of Sickle Red Blood Cells in Microvessels for Bio Medical Application. The Yale Journal of Biology and Medicine, 96, 13-21.
https://doi.org/10.59249/atvg1290
[25]  Shah, S.R. (2012) A Case Study on Non-Newtonian Viscosity of Blood through Atherosclerotic Artery. Asian Journal of Engineering and Applied Technology, 1, 47-52.
https://doi.org/10.51983/ajeat-2012.1.1.2501
[26]  Ratan Shah, S. (2011) Non-Newtonian Flow of Blood through an Atherosclerotic Artery. Research Journal of Applied Sciences, 6, 76-80.
https://doi.org/10.3923/rjasci.2011.76.80
[27]  Zid, I., Alilat, D., Rebhi, R., Alliche, M., Chamkha, A.J. and Zeguai, S. (2025) MHD Natural Convection of Non-Newtonian Carreau-Yasuda Nanofluid in a Square Porous Cavity by Dupuit-Darcy Model. The European Physical Journal Plus, 140, Article No. 450.
https://doi.org/10.1140/epjp/s13360-025-06407-9
[28]  Ojha, M., Cobbold, R.S.C., Johnston, K.W. and Hummel, R.L. (1989) Pulsatile Flow through Constricted Tubes: An Experimental Investigation Using Photochromic Tracer Methods. Journal of Fluid Mechanics, 203, 173-197.
https://doi.org/10.1017/s0022112089001424
[29]  Toufique Hasan, A.B.M. and Dipak Kanti, D. (2008) Numerical Simulation of Sinusoidal Fluctuated Pulsatile Laminar Flow through Stenotic Artery. Journal of Applied Fluid Mechanics, 1, 25-35.
[30]  Lee, K.W. and Xu, X.Y. (2002) Modelling of Flow and Wall Behaviour in a Mildly Stenosed Tube. Medical Engineering & Physics, 24, 575-586.
https://doi.org/10.1016/s1350-4533(02)00048-6

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133