全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Linear Measurement of Corneal Density in Anterior Segment Spectral Optical Coherence Tomography (LM-SD-OCT)

DOI: 10.4236/ojoph.2025.153016, PP. 115-121

Keywords: Anterior Segment Optical Coherence Tomography, Optical Density, Densitometry

Full-Text   Cite this paper   Add to My Lib

Abstract:

Purpose: assess the accuracy of linear corneal density measurements obtained using spectral domain optical coherence tomography (OCT) in various images of normal corneas with the Image J program. Methods: Descriptive, cross-sectional, and observational study. Corneal images were captured using OCT Heidelberg Engineering with an anterior segment lens to calculate the average density of each layer in healthy corneas. We included subjects without corneal pathologies or surgeries and categorized them based on their age: 30 to 50 years, 51 to 70 years, and older than 70 years. The program image J of the NIH was used to calibrate the OCT image at a standardized value of 200 μm. Densities were obtained for the central cornea using high-resolution 8-bit images with 256 gray levels. Results: Spectral corneal OCT images of 140 eyes (170 patients) were analyzed, comprising 90 males and 80 females. The average gray value density for each corneal layer was determined, as follows: Te ar layer (238.25 ± 17.49), epithelium interface (91.55 ± 17), basal membrane and Bowman’s membrane (167.76 ± 16.19), anterior stroma (152.06 ± 9.09), posterior stroma (130.24 ± 8.32), and Descemet membrane (149.21 ± 7.80). Notably, optical densities significantly varied across different age groups and corneal layers (p < 0.05). Conclusions: The linear corneal layer densities obtained using the linear mode of spectral domain optical coherence tomography (SD-OCT) with Image J were a fast and practical method to complement the subjective descriptions of spectral anterior segment OCT images. These densities can then be compared across various pathologies.

References

[1]  Elsawy, A., Abdel-Mottaleb, M., Sayed, I., Wen, D., Roongpoovapatr, V., Eleiwa, T., et al. (2019) Automatic Segmentation of Corneal Microlayers on Optical Coherence Tomography Images. Translational Vision Science & Technology, 8, Article 39.
[2]  Han, S.B., Liu, Y., Noriega, K.M. and Mehta, J.S. (2016) Applications of Anterior Segment Optical Coherence Tomography in Cornea and Ocular Surface Diseases. Journal of Ophthalmology, 2016, Article ID: 4971572.
https://doi.org/10.1155/2016/4971572
[3]  Doors, M., Berendschot, T.T.J.M., de Brabander, J., Webers, C.A.B. and Nuijts, R.M.M.A. (2010) Value of Optical Coherence Tomography for Anterior Segment Surgery. Journal of Cataract and Refractive Surgery, 36, 1213-1229.
https://doi.org/10.1016/j.jcrs.2010.05.002
[4]  Maidana, D.E., Tsoka, P., Tian, B., Dib, B., Matsumoto, H., Kataoka, K., et al. (2015) A Novel ImageJ Macro for Automated Cell Death Quantitation in the Retina. Investigative Opthalmology & Visual Science, 56, 6701-6708.
[5]  Butt, G., Brock, K., Ng, A., Vareechon, C., Pearlman, E., Hill, L.J., Wallace, G.R. and Rauz, S. (2018) Using ImageJ to Quantify Microbial Keratitis Related Corneal Opacification in a Mouse Model. Investigative Ophthalmology & Visual Science, 59, Article 5851.
[6]  Rueden, C.T., Schindelin, J., Hiner, M.C., DeZonia, B.E., Walter, A.E., Arena, E.T., et al. (2017) ImageJ2: ImageJ for the Next Generation of Scientific Image Data. BMC Bioinformatics, 18, Article No. 529.
https://doi.org/10.1186/s12859-017-1934-z
[7]  He, Y., Ma, B.S., Zeng, J.H. and Ma, D.J. (2023) Corneal Optical Density: Structural basis, Measurements, Influencing Factors, and Roles in Refractive Surgery. Frontiers in Bioengineering and Biotechnology, 11, Article ID: 1144455.
https://doi.org/10.3389/fbioe.2023.1144455
[8]  Wertheimer, C.M., Elhardt, C., Wartak, A., Luft, N., Kassumeh, S., Dirisamer, M., et al. (2020) Corneal Optical Density in Fuchs Endothelial Dystrophy Determined by Anterior Segment Optical Coherence Tomography. European Journal of Ophthalmology, 31, 1771-1778.
https://doi.org/10.1177/1120672120944796
[9]  Coskun, C., Çelik, G., Zeki Fikret, C., Çomçalı, S. and Evren Kemer, Ö. (2024) Evaluation of Corneal Densitometry Values with Pentacam in Cases of Ocular Hypertension and Pseudoexfoliative Glaucoma. Photodiagnosis and Photodynamic Therapy, 46, Article 103988.
https://doi.org/10.1016/j.pdpdt.2024.103988

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133