Two flow methods, based, respectively, on flow-injection analysis (FIA) and on multicommutated flow analysis (MCFA), were compared with regard to their use for the determination of total selenium in infant formulas by hydride-generation atomic absorption spectrometry. The method based on multicommutation provided lower detection and quantification limits (0.08 and 0.27?μg?L?1 compared to 0.59 and 1.95?μ?L?1, resp.), higher sampling frequency (160 versus. 70 samples per hour), and reduced reagent consumption. Linearity, precision, and accuracy were similar for the two methods compared. It was concluded that, while both methods proved to be appropriate for the purpose, the MCFA-based method exhibited a better performance. 1. Introduction The importance of selenium for the life of animals has been known since the 1950s, while the essentiality of this element for humans was revealed in 1970s with the discovery of its ability to prevent the Keshan disease, first described in 1935 in China in a province of the same name [1]. Subsequently, it was discovered its important role as part of the body’s antioxidant mechanisms and also its role in protecting the body against heavy metals as well as its importance in the immune system [1, 2]. Cow’s milk and dairy products are usually a poor source of selenium in human nutrition. Human milk is considered the best source of selenium for young children and infants [3]. However, human milk is a poor source of selenium, so recently manufacturers of dairy-based infant formulas have added selenium to these products. Selenium has a very narrow range between dietary deficiency (<40?μg/day for adults) and toxic levels (>400?μg/day). For this reason, it is very important to have control of the selenium intake by human and animals. Several analytical techniques are suitable for determining total selenium in milk, such as neutron activation analysis (Instrumental Neutron Activation Analysis (INAA)), fluorimetry, gas chromatography (GC), and atomic absorption spectrometry (AAS) [4]. The neutron activation technique is not available in most laboratories; it is generally used for determinations of selenium in certified reference materials as an alternative method and in proficiency testing. It has the advantage of being a nondestructive technique, but the detection limits are usually higher than for other techniques [3, 4]. Other methods usually are based on the generation of a piazselenol complex, which is subsequently submitted to different detection techniques. For instance, a fluorimetric method is recommended in the bulletin of
References
[1]
P. Tiglea and E. Mello De Capitani, “Selenio,” in Metais, Geranciamento da Toxicidade, F. A. De Azeredo and A. A. Da Matta Chasin, Eds., pp. 239–262, Editora Atheneu, S?o Paulo, Brazil, 2003.
[2]
F. Fordyce, “Selenium Deficiency and Toxicity in the Environment,” in Essentials of Medical Geology. Impacts of the Natural Environment on Public Health, O. Selinus, B. Alloway, J. A. Centeno, et al., Eds., pp. 373–415, Elsevier, Burlington, Mass, USA, 2005.
[3]
M. S. Alaejos and C. D. Romero, “Selenium concentration in milks,” Food Chemistry, vol. 52, no. 1, pp. 1–18, 1995.
[4]
L. H. Foster and S. Sumar, “Methods of analysis used for the determination of selenium in milk and infant formulae: a review,” Food Chemistry, vol. 53, no. 4, pp. 453–466, 1995.
[5]
Bulletin of the International Dairy Federation no 278/1992, Copper. Trace Elements in milk and milk products, pp. 16-20, IDF, Brussels, Belgium, 1992.
[6]
“AOAC. Official methods of analysis. 974.15,” in Selenium in Human and Pet Food, M. Ihnat, Ed., pp. 28–29, AOAC International, Arlington, Va, USA, 1996.
[7]
Z. Marczenko and M. Balcerzak, Separation, Preconcentration and Spectrophotometry in Inorganic Analysis, Analytical Spectroscopy Library, Elsevier Science, Amsterdam, The Netherlands, 2000.
[8]
A. Paiva Oliveira, J. A. Gomes Neto, J. Araújo Nóbrega, P. R. Miranda Correia, and P. Vitoriano Oliveira, “Determination of selenium in nutritionally relevant foods by graphite furnace atomic absorption spectrometry using arsenic as internal standard,” Food Chemistry, vol. 93, no. 2, pp. 355–360, 2005.
[9]
C. Sola-Larra?aga and I. Navarro-Blasco, “Chemometric analysis of minerals and trace elements in raw cow milk from the community of Navarra, Spain,” Food Chemistry, vol. 112, no. 1, pp. 189–196, 2009.
[10]
J. Dědina, “Flow methods in gas-liquid separations,” in Flow Analysis with Atomic Spectrometric Detectors, A. Sanz-Medel, Ed., Elsevier Science, Amsterdam, The Netherlands, 1999.
[11]
W. R. Mindak and S. P. Dolan, “Determination of arsenic and selenium in food using a microwave digestion-dry ash preparation and flow injection hydride generation atomic absorption spectrometry,” Journal of Food Composition and Analysis, vol. 12, no. 2, pp. 111–122, 1999.
[12]
O. Mu?iz-Naveiro, R. Domínguez-González, A. Bermejo-Barrera et al., “Selenium content and distribution in cow's milk supplemented with two dietary selenium sources,” Journal of Agricultural and Food Chemistry, vol. 53, no. 25, pp. 9817–9822, 2005.
[13]
R. Danby and S. Shaw, GBC HG3000. Automatic Hydride Generator. Operation Manual, GBC Scientific Equipment Pty, Victoria, Australia, 1990.
PerkinElmer, “Recommended analytical conditions and general information for flow injection mercury/hydride analyses using the PerkinElmer FIAS-100/400,” Technical Data Sheets, PerkinElmer Inc. Copyright 1998–2009, http://www.perkinelmer.com/CMSResources/Images/44-74841TCH_FIASAnalyticalConditions.pdf.
[16]
J. Ruzicka and E. Hansen, Flow Injection Analysis, John Wiley & Sons, New York, NY, USA, 2nd edition, 1989.
[17]
M. Trojanowicz, Flow Injection Analysis: Instrumentation and Applications, World Scientific, Singapore, 2000.
[18]
Y. Zhang and S. B. Adeloju, “Flow injection-hydride generation atomic absorption spectrometric determination of selenium, arsenic and bismuth,” Talanta, vol. 76, no. 4, pp. 724–730, 2008.
[19]
D. Mazej, M. Horvat, F. Barbone, and V. Stibilj, “Simple and rapid method for determination of selenium in breast milk by HG-AFS,” Microchimica Acta, vol. 147, no. 1-2, pp. 73–79, 2004.
[20]
O. Mu?iz-Naveiro, R. Domínguez-González, A. Bermejo-Barrera, P. Bermejo-Barrera, J. A. Cocho, and J. M. Fraga, “Study of the bioavailability of selenium in cows' milk after a supplementation of cow feed with different forms of selenium,” Analytical and Bioanalytical Chemistry, vol. 385, no. 1, pp. 189–196, 2006.
[21]
E. Ródenas-Torralba, P. Cava-Montesinos, A. Morales-Rubio, M. L. Cervera, and M. De La Guardia, “Multicommutation as an environmentally friendly analytical tool in the hydride generation atomic fluorescence determination of tellurium in milk,” Analytical and Bioanalytical Chemistry, vol. 379, no. 1, pp. 83–89, 2004.
[22]
S. Moyano, J. A. Gásquez, E. Marchevsky, R. Olsina, and L. D. Martinez, “The determination of Se by flow injection hydride generation ICP-OES using anion exchange for on-line removal of copper,” Atomic Spectroscopy, vol. 18, no. 5, pp. 152–155, 1997.
[23]
N. Etxebarria, R. Antolín, G. Borge, T. Posada, and J. C. Raposo, “Optimisation of flow-injection-hydride generation inductively coupled plasma spectrometric determination of selenium in electrolytic manganese,” Talanta, vol. 65, no. 5, pp. 1209–1214, 2005.
[24]
N. V. Semenova, L. O. Leal, R. Forteza, and V. Cerdà, “Multisyringe flow injection system for total inorganic selenium determination by hydride generation-atomic fluorescence spectrometry,” Analytica Chimica Acta, vol. 486, no. 2, pp. 217–225, 2003.
[25]
F. R. P. Rocha, B. F. Reis, E. A. G. Zagatto, J. L. F. C. Lima, R. A. S. Lapa, and J. L. M. Santos, “Multicommutation in flow analysis: concepts, applications and trends,” Analytica Chimica Acta, vol. 468, no. 1, pp. 119–131, 2002.
[26]
M. Catalá Icardo, J. V. García Mateo, and J. Martínez Calatayud, “Multicommutation as a powerful new analytical tool,” Trends in Analytical Chemistry, vol. 21, no. 5, pp. 366–378, 2002.
[27]
M. A. Feres, P. R. Fortes, E. A. G. Zagatto, J. L. M. Santos, and J. L. F. C. Lima, “Multi-commutation in flow analysis: recent developments and applications,” Analytica Chimica Acta, vol. 618, no. 1, pp. 1–17, 2008.
[28]
E. J. Llorent-Martínez, P. O. Barrales, M. Luisa Fernández-de Córdova, and A. Ruiz-Medina, “Multicommutation in flow systems: a useful tool for pharmaceutical and clinical analysis,” Current Pharmaceutical Analysis, vol. 6, no. 1, pp. 53–65, 2010.
[29]
M. Pistón, J. Silva, R. Pérez-Zambra, and M. Knochen, “Determination of total selenium by multicommutated-flow hydride generation atomic absorption spectrometry. Application to cow's milk and infant formulae,” Analytical Methods, vol. 1, no. 2, pp. 139–143, 2009.
[30]
F. D. Pierce and H. R. Brown, “Inorganic interference study of automated arsenic and selenium determination with atomic absorption spectrometry,” Analytical Chemistry, vol. 48, no. 4, pp. 693–695, 1976.
[31]
R. M. Brown Jr., R. C. Fry, J. L. Moyers, S. J. Northway, M. B. Denton, and G. S. Wilson, “Interference by volatile nitrogen oxides and transition-metal catalysis in the preconcentration of arsenic and selenium as hydrides,” Analytical Chemistry, vol. 53, no. 11, pp. 1560–1566, 1981.
[32]
L. H. Foster and S. Sumar, “Hydride generation atomic absorption spectrometric (HGAAS) determination of selenium in term and preterm infant formulae available in the United Kingdom,” Food Chemistry, vol. 55, no. 3, pp. 293–298, 1996.
[33]
J. N. Miller and J. C. Miller, Estadística para Química Analítica, Addison-Wesley Iberoamerican S.A., Wilmington, Del, USA, 2nd edition, 1993.
[34]
D. L. Massart, B. G. M. Vandeginste, L. M. C. Buydens, S. De Jong, P.J. Lewi, and J. Smeyers-Verbeke, Handbook of Chemometrics and Qualimetrics: Part A, Elsevier Science, Amsterdam, The Netherlands, 1997.