Effect of Methanol in the Wash-Solvent Bottle and the OnGuard Cartridges on the Determination of Different Anions Using Ion Chromatography

DOI: 10.4236/ajac.2012.32025, PP. 175-179

Keywords: Ion Chromatography, Interference, Anions, Methanol, OnGuard Cartridges

Full-Text   Cite this paper   Add to My Lib

Abstract:

The effect of using methanol in the flush-solvent bottle of the auto-sampler of Ion Chromatograph on the determination of sulfate ions was studied using AS11-HC 2 mm analytical column. The use of 50% methanol in the flush solvent bottle results in overestimation of sulfate concentration by 18%. However, the use of 10% methanol instead of 50% did not show such error in the determination of sulfate using the same column. Furthermore, the effect of using OnGuard-RP and OnGuard-P cartridges for sample pretreatment on the determination of different anions was also studies using AS14-HC 2 mm analytical column. The results indicate that using OnGuard-RP cartridge caused the concentration of fluoride, bromide, nitrate, phosphate and sulfate ions to be underestimated, whereas the concentration of chloride ions to be overestimated. The error in the determination of fluoride, bromide, nitrate, phosphate sulfate, and chloride was found to be 40.0%, 26.0%, 22.8%, 26.8%, 18.0%, and 25.0% of the certified standard concentration, respectively. It was also found that the use of OnGuard-P cartridge resulted in underestimation of fluoride, chloride, bromide, nitrate, phosphate, and sulfate by 60.0%, 40.0%, 82.0%, 87.2%, 45.2%, and 39.0% of the certified standard concentration, respectively. These findings point out to careful corrections that should be considered in any application of ion chromatography utilizing such sample pretreatment.

References

[1]  D. A. Skoog, F. J. Holler and S. R. Crouch, “Principles of In-strumental Analysis,” Brooks/Cole, Belmont, 2007.
[2]  P.R. Haddad, P.E. Jackson, “Ion Chromatography: Principles and Applications,” Elsevier, New York, 1990.
[3]  B. López-Ruiz, “Advances in the Determination of Inorganic Anions by Ion Chromatography,” Journal of Chromatography A, Vol. 881, No. 1-2, 2000, pp. 607-627. doi:10.1016/S0021-9673(00)00244-2
[4]  C. A. Lucy, “Recent Advances in Ion Chromatography: A Perspective,” Journal of Chromatography A, Vol. 739, No. 1-2, 1996, pp. 3-13. doi:10.1016/0021-9673(96)00034-9
[5]  J. H. Lee, J. S. Kim, B. H. Min, S. T. Kim and J. H. Kim, “Determination of Anions in Certified Reference Materi- als by Ion Chromatography,” Journal of Chromatography A, Vol. 813, No. 1, 1998, pp. 85-90. doi:10.1016/S0021-9673(98)00267-2
[6]  P. N. Nesterenko, “Simultaneous Separation and Detec- tion of Anions and Cations in Ion Chromatography,” TrAC Trends in Analytical Chemistry, Vol. 20, No. 6-7, 2001, pp. 311-319. doi:10.1016/S0165-9936(01)00072-3
[7]  R. Garc??a-Fernández, J. I. Garc??a-Alonso and A. Sanz- Medel, “Simultaneous Determination of Inorganic Anions, Calcium and Magnesium by Suppressed Ion Chromatography,” Journal of Chromatography A, Vol. 1033, No. 1, 2004, pp. 127-133. doi:10.1016/j.chroma.2004.01.024
[8]  J. S. Fritz, “Factors Affecting Selectivity in Ion Chroma- tography,” Journal of Chromatography A, Vol. 1085, No. 1, 2005, pp. 8-17. doi:10.1016/j.chroma.2004.12.087
[9]  P. R. Haddad, P. E. Jackson and M. J. Shaw, “Developments in Suppressor Tech-nology for Inorganic Ion Analysis by Ion Chromatography Using Conductivity Detection,” Journal of Chromatography A, Vol. 1000, No. 1-2, 2003, pp. 1903-2003. doi:10.1016/S0021-9673(02)01999-4
[10]  W. Hu, H. Tao, M. Tominaga, A. Miyazaki and H. Haraguchi, “A New Approach for the Simultaneous Determination of Inorganic Cations and Anions Using Ion Chromatography,” Analytica Chimica Acta, Vol. 299, No. 2, 1994, pp. 249-256. doi:10.1016/0003-2670(94)00347-5
[11]  Y. Ding and S. Mou, “Effects of Common Metal Ions on the Determination of Anions by Suppressed Ion Chromatography,” Journal of Chromatography A, Vol. 956, No. 1-2, 2002, pp. 65-70. doi:10.1016/S0021-9673(01)01545-X

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133