Modeling and Analysis of Electrical Protection Systems: The Case of ZIZ Energie Mongo’s H61 Substations in the Sahelian Zone of Guéra (Chad) during the Rainy Season

DOI: 10.4236/epe.2026.1811035, PP. 758-776

Keywords: MATLAB/Simulink, Lightning, ZnO Surge Arrester, H61 Substation, Distribution Network, ZIZ Energie de Mongo, Rainy Season, Sahelian Zone, Keraunic Level, Grounding

Full-Text   Cite this paper   Add to My Lib

Abstract:

Mongo, the capital of the Guéra province, is located within the central Chadian massif, in the heart of the Sahel-Sudan belt. It lies between 12?10'58''N and 18?41'05''E, in a strategic climatic zone subject to the seasonal oscillations of the Intertropical Convergence Zone and, consequently, to climatic constraints. The rainy season extends from May/June to October, with annual precipitation ranging from 300 to 800 mm; the peak of the season occurs in July and August. In this region, lightning-induced overvoltages pose the most severe challenges for H61 transformer substations due to high lightning activity and humidity. These climatic factors compromise grid stability and expose overhead distribution substations to significant risks of insulation breakdown caused by atmospheric overvoltages. This study focuses on modeling a protection system for H61 overhead substations operated by the local electricity utility (ZIZ énergie) in Mongo a Sahelian zone specifically during the rainy season. A key aspect of the analysis is examining the behavior of the H61 transformer both with and without ZnO (zinc oxide) surge arresters. The results demonstrate that, in the absence of protection (i.e., without ZnO surge arresters), lightning strikes cause severe damage to the H61 transformer, impairing its operation and potentially rendering it inoperable. Integrating surge arresters and ensuring they are positioned as close as possible to the transformer provides effective and adequate protection. Furthermore, this research provides a valuable decision-support tool for researchers and experts in the field of electrical protection. MATLAB/Simulink is used for this purpose.

References

[1]  Bedoui, S. and Bayadi, A. (2007) Atténuation des surtensions dans les postes de transformation haute tension par l’emploi des parafoudres ZnO. Université Ferhat Abbas.
http://dspace.univ-setif.dz:8888/jspui/handle/123456789/9
[2]  Forma TIS (2026) Parafoudre. Forma TIS.
https://blog.formatis.pro/parafoudre/
[3]  (2014) Surge Arresters—Part 4: Metal-Oxide Surge Arresters without Gaps for A.C. Systems.
https://cdn.standards.iteh.ai/samples/18691/570872f782d245c8b028278532ab73a4/IEC-60099-4-2014.pdf
[4]  Aoues, M.M., Birouche, M.C., Miouat, M.A. and Djoudi, M.H. (2014) Etude des protections d’un réseau MT application poste de boukhalfa 60/30kV. Université Mouloud Mammeri.
https://dspace.ummto.dz/
[5]  Safia, K. and Lila, B. (2011) Protection des transformateurs MT/BT contre les surtensions de foudre. Université Mouloud Mammeri.
https://dspace.ummto.dz/handle/ummto/8531
[6]  Bouzid, S. and Imarazene, A. (2014) Modernisation de la protection des autotrans-formateurs contre les surtensions atmosphériques. Mémoire de Master, Université Mouloud Mammeri de Tizi-Ouzou.
[7]  Aoudia, M., Azzoug, A. and Belhocine, M. (2011) Etude des protections du poste source freha 60/30 kv contre les surtensions. Université Mouloud Mammeri de Tizi-Ouzou.
https://dspace.ummto.dz/server/api/core/bitstreams/ee5361b5-e683-4e33-8cae-a2116308681d/content
[8]  INSEED (2026) Institut national de la statistique et des études économiques et demographiques. INSEED.
https://www.inseed.td/
[9]  Studocu (1996) NF C 11 201: Réseaux de distribution publique d’énergie.
https://www.studocu.com/row/document/universite-de-ndjamena/exercice-pratique/nf-c-11-201-reseaux-de-distribution-publique-denergie-norme-1996/148935577
[10]  Parafoudres.
https://assets.legrand.com/general/ouidoo/pdf/legrand-guide-technique-parafoudres.pdf
[11]  Shutterstock (2026) 1,3 Millier Images et Photos de Lightning over Beach Libres de Droits.
https://www.shutterstock.com/fr/search/lightning-over-beach
[12]  IEEE Standards Association (2026) IEEE Standard for Metal-Oxide Surge Arresters for AC Power Circuits (> 1 kV).
https://standards.ieee.org/ieee/C62.11/5839/
[13]  Bayadi, A., Harid, N., Zehar, K. and Belkhiat, S. (2003) Simulation of Metal Oxide Surge Arrester Dynamic Behavior under Fast Transients. Proceedings of the International Conference on Power Systems Transients (IPST), New Orleans, June 2003.
[14]  Meghezzi, A. and Sidi Said, A. (2013) étude des surtensions dues à la ferrorésonance en phases incomplètes.
https://dspace.ummto.dz/server/api/core/bitstreams/36ea55f0-b4f7-423c-8179-fad57d0c5845/content
[15]  30kV/BT 160kVA-100kVA-50kVA MT transformateurs haut de poteau huile de type H61_fabricant de Chine-Engelec Power Technology CO., LTD.
https://www.engelecgroup.com/30kV-BT-160kVA-100kVA-50kVA-MT-transformateurs-haut-de-poteau-huile-de-type-H61-pd767411198.html
[16]  Mahseredjian, J., Xémard, A. and Khodabakhchian, B. (2007) Régimes transitoires dans les réseaux électriques.
https://www.techniques-ingenieur.fr/ressources-documentaires/energies-th4/conversion-de-l-energie-electrique-ti301/regimes-transitoires-dans-les-reseaux-electriques-d82

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133