Mechanical Failure of Internal Fixation and Arthroplasty Implants in the Department of Orthopaedics and Traumatology, Bouaké University Hospital, C?te d’Ivoire
Objective: To describe the mechanical failures of internal fixation constructs and arthroplasty implants managed. Materials and Methods: We conducted a cross-sectional, descriptive observational study of all patients admitted and treated for mechanical failure of an internal fixation construct or of an arthroplasty implant between 2015 and 2025. The variables studied were the characteristics of the series and the characteristics of the mechanical failures. Results: Forty-three patient records were collected over the study period. The mean age was 40 ± 16 years. There were 27 men (63%). Loosening or disassembly of the fixation construct and implant breakage accounted for 53% (n = 23) and 30% (n = 13) of cases, respectively. Arthroplasty failure occurred in two cases (5%). The most frequent causes were unauthorised early weight-bearing on the lower limb (n = 15; 35%), comminuted fracture (n = 7; 16%) and unidentified causes (n = 7; 16%). Treatment consisted of implant removal followed by revision fixation with a screw plate (n = 15; 35%), a locked intramedullary nail (n = 13; 31%) or a sliding hip screw-plate (n = 9; 21%), and cemented bipolar hemiarthroplasty (n = 2; 5%). Five postoperative infections were recorded (11%). Among the 35 patients reviewed, the mean time to bone union was 6 ± 2 months (range 4 - 7). Both revised arthroplasties had a favourable outcome. Conclusion: Loosening or disassembly of the internal fixation construct was the most frequently observed mechanical failure in this series, with the femur as the predominant site. Arthroplasty failure was rare. The most frequent cause was unauthorised early weight-bearing on the lower limb.
References
[1]
Burny, F., Bourgois, R. and Lemaire, L. (1974) Failure of the Osteosynthesis Material: Implication of the Implant. Acta Orthopaedica Belgica, 37, 846-860.
[2]
Hunter, S.G. (1982) The Migration of Femoral Küntscher Nails: A Clinical Study. Injury, 13, 460-463. https://doi.org/10.1016/0020-1383(82)90159-0
[3]
Müller, M.E. (1976) Pitfalls of Internal Fixation [Pièges de l’ostéosynthèse]. Conférencesd’Enseignementdela SOFCOT, 6, 95-113.
[4]
Moyikoua, A. and Pena-Pitra, B. (1993) Mechanical Complications of Osteosynthesis of the Lower Limb: Analysis of 22 Cases. Medecined’Afriquenoire, 40, 509-515.
[5]
Traore, M., Gogoua, R., Kouame, M., Yepie, A., Anoumou, M. and Varango, G. (2017) Mechanical Complications after Limb Osteosynthesis: Analysis of Etiologic Factors in 42 Cases. Open Journal of Orthopedics, 7, 43-52. https://doi.org/10.4236/ojo.2017.72006
[6]
Tekpa, B.J.D., Yafondo, T.A., Nguena-Yamalet, U., Issa-Mapouka, A., Fassioni, E., et al. (2020) Mechanical Complications of Osteosynthesis in a Developing Country: Frequency and Risk Factors. International Journal of Musculoskeletal Disorders, 4, 1-7.
[7]
Mujinga, I.M.W., Ilunga, G.N., Baba, A.L.A., Mukakala, A.K., Kitoko, H.T., Ntanga, D.I., et al. (2024) Surgical Revision of Limb Osteosynthesis at the University Clinics of Lubumbashi: Epidemiological, Clinical, Aetiological, Therapeutic and Outcome Features. Revue Africaine de Médecine etde Santé Publique, 7, 182-204.
[8]
Mudiangombe, N., Mbodji, M., Jalloh, M., Kabeya, Y., Kyungu, Y., Diagne, S., et al. (2023) Migration pelvienne d’une broche guide au cours d’une ostéosynthèse pour fracture de la hanche: à propos de 2 cas. African Urology, 3, 184-185. https://doi.org/10.36303/auj.0114
[9]
Ware, J.E., Kosinski, M. and Keller, S.D. (1996) A 12-Item Short-Form Health Survey: Construction of Scales and Preliminary Test of Reliability and Validity. Medical Care, 34, 220-233. https://doi.org/10.1097/00005650-199603000-00003
[10]
Sheffler, L.C., Yoo, B., Bhandari, M. and Ferguson, T. (2013) Observational Studies in Orthopaedic Surgery: The STROBE Statement as a Tool for Transparent Reporting. Journal of Bone and Joint Surgery, 95, e14. https://doi.org/10.2106/jbjs.l.00484
[11]
Essadki, B. and Lamine, A. (2000) The Aseptic Mechanical Complications of Fractures of the Femoral Diaphysis Treated by Screwed Plates. Acta Orthopaedica Belgica, 66, 61-68.
[12]
Essadki, B., Largab, A., El Ibrahimi, A. and Elmrini, A. (2003) Revision of Total Hip Arthroplasty: A Series of 60 Cases. Revue de Chirurgie Orthopédique et Réparatrice de l’Appareil Moteur, 89, 553-560.
[13]
Ibrahimou, T.K., Ibrahimou, B., Makekita, W.N. and Mudimisi, M. (2016) The Mechanical Complications of Centromedullary Nailing of the Femur in a Precarious Environment: Report of Six Observations at N’Djili Hospital, Kinshasa. Revue médicale des Grands Lacs, 5, 96-103.
[14]
Gogoua, D., Touré, S., Anoumou, M., Kouamé, M., Koné, B. and Varango, G. (2006) Mechanical Complications of Osteosynthesis of Limb Fractures: An Epidemiological Analysis of 26 Observations. Mali Médical, 21, 5-9.
[15]
Loubignac, F. and Chabas, J.F. (2009) A Newly Designed Locked Intramedullary Nail for Trochanteric Hip Fractures Fixation: Results of the First 100 Trochanteric? Implantations. Orthopaedics & Traumatology: Surgery & Research, 95, 139-144. https://doi.org/10.1016/j.otsr.2009.01.002
[16]
Batchom, A.D., Nana, C.T., Arabo, S. and Handy Eoné, D. (2021) Mechanical Failure of Osteosynthesis Using Nails, Plates and Blade Plates at Laquintinie Hospital, Douala. La Revue de Médecine et de Pharmacie de Douala, 11, 1321-1325. https://www.ajol.info/index.php/rmp/article/view/229205
[17]
W’Ifongo, W., Lembalemba, B., Kalokola, L. and Afelokoky, E. (2014) Nail Migration and Bending, Two Complications of Centromedullary Nailing of the Femur: A Case Observed at the University Clinics of Kisangani, Democratic Republic of the Congo. Kisangani Médical, 5, 104-108.
[18]
Parvizi, J., Rapuri, V.R., Purtill, J.J., Sharkey, P.F., Hozack, W.J. and Rothman, R.H. (2004) Treatment Protocol for Infected Total Hip Arthroplasty. The Journal of Bone and Joint Surgery—American Volume, 86, 134-143.
[19]
Ramaniraka, N.A., Rakotomanana, L.R. and Leyvraz, P.F. (2000) The Fixation of the Cemented Femoral Component: Effects of Stem Stiffness, Cement Thickness and Roughness of the Cement-Bone Surface. The Journal of Bone and Joint Surgery—British Volume, 82, 297-303.
[20]
Schwarzkopf, R., Oni, J.K. and Marwin, S.E. (2014) Total Hip Arthroplasty Revision: Current Concepts. Orthopedic Clinics of North America, 45, 257-268.