Effects of Carbon Film and Chloride Ions on the Pitting Corrosion of Copper in Anion Exchange-Treated Water Containing Water Treatment Chemicals

DOI: 10.4236/msa.2026.1710017, PP. 255-266

Keywords: Copper, Carbon Film, Pitting Corrosion, Anion Exchange-Treated Water, Chloride Ion, Benzotriazole, Phosphonic Acid

Full-Text   Cite this paper   Add to My Lib

Abstract:

Copper tubes are widely used in heat exchangers for air conditioning units and refrigerators. Carbon film formed on the inner surface of copper tubes during manufacturing have been reported to cause carbon-film-dependent pitting corrosion interaction with the quality of the water flowing in the tube. In field applications phosphonic acid (HEDP) and benzotriazole (BTA) are used to suppress this pitting corrosion. Anion exchange-treated water, produced by passing tap water through anion exchange resin to replace corrosive ions (Cl? and S O 4 2? ) with corrosion inhibiting ions ( HC O 3 ? ), it has also been reported to improve corrosion resistance when combined with these water treatment chemicals. In this study, the effects of chloride ion concentration and carbon film on the corrosion resistance of copper in anion exchange-treated water containing water treatment chemicals were investigated. Corrosion potential and anodic polarization curves were measured in anion-exchange treated water containing 10 mg/L of HEDP and 5 mg/L of BTA, at various chloride ion concentrations. Copper tube specimens with residual carbon amounts of 0 mg/m2 and 5 mg/m2 were used. Corrosion potential measurements show that the corrosion potential decreased and corrosion was occurred in the presence of carbon film at a chloride ion concentration of 100 mg/L. Anodic polarization curve measurement showed that the breakdown potential shifted to the less noble potential side as the chloride ion concentration increased. These results indicate that, in anion-exchange-treated water containing water treatment chemicals, corrosion is more likely to occur as the Cl? concentration increases. Furthermore, the presence of a carbon film is considered to enhance this tendency.

References

[1]  Yamada, Y., Mori, A., Hatanaka, R., Atsumi, T. and Nakao, N. (1998) Pitting Corrosion of Copper Coiled Tubes in the Air Conditioning System Having the Open Heat Storage Water Tank. Zairyo-to-Kankyo, 47, 723-728.
https://doi.org/10.3323/jcorr1991.47.723
[2]  Osami, S., Kajikawa, H., Sasaki, M., Yamada, Y., Toda, I. and Iitsuka, M. (2002) Effect of Residual Carbon Deposit on Corrosion Behavior of Copper Tube in Air Conditioner Water. Journal of the Institute of Copper, 41, 131-135.
[3]  Sakai, M., Seri, O., Yamada, Y., Toda, I. and Iitsuka, M. (2002) Effect of Residual Carbon Deposits on Corrosion Behavior of Copper Tube Filled with Water. Zairyo-to-Kankyo, 51, 12-16.
https://doi.org/10.3323/jcorr1991.51.12
[4]  Aramaki, K. (1976) Introduction to Corrosion Inhibitors. Corrosion Engineering, 25, 693-702.
https://doi.org/10.3323/jcorr1974.25.11_693
[5]  Yamada, Y., Seri, O., Tagashira, K. and Nagata, K. (1993) Pitting Corrosion of Copper in Aqueous Solutions Containing Phosphonic Acid as an Inhibitor. Zairyo-to-Kankyo, 42, 558-563.
https://doi.org/10.3323/jcorr1991.42.558
[6]  Sakai, M., Yamagishi, N. and Matsumoto, N. (2012) Corrosion Behavior and Pitting Morphology of Copper in Synthetic Freshwater Containing Silica. Zairyo-to-Kankyo, 61, 48-51.
https://doi.org/10.3323/jcorr.61.48
[7]  Yamaguchi, Y., Sasaki, T., Kuratani, M., Iyasu, T., Yamada, Y. and Sakurada, O. (2022) Effects of Silicate on Corrosion Resistance of Copper Tube by Cooling Water System Water Treatment Chemical. Journal of Japan Institute of Copper, 61, 154-158.
https://doi.org/10.34562/jic.61.1_154
[8]  Yuichi, O. and Taneno, M. (1996) Anticorrosive Effect of Anion Exchange Treatment on Carbon Steel and Copper in a Closed Cooling Water System. Proceeding of Japan Corrosion Conference, Suita, 16-18 October 1996, 261-264.
[9]  Takasaki, S. and Yamada, Y. (2007) Effects of Temperature and Aggressive Anions on Corrosion of Carbon Steel in Potable Water. Corrosion Science, 49, 240-247.
https://doi.org/10.1016/j.corsci.2006.05.035
[10]  Nakamura, Y., Yamada, I., Matsukawa, Y., Okazaki, S. and Asakura S. (2021) Crrosion Countermeasure for Building Equipment in Water Pitting System Part1-Corrosion Prevention Nature for Carbon Steel in Tap Waters Treated with Anion Exchange Resin. Journal of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan, 46, 57-65.
https://doi.org/10.18948/shase.46.297_57
[11]  Matsumoto, M., Aoyama, R., Takahashi, F., Nakamura, Y., Matsukawa, Y., Yamada, Y., et al. (2026) The Effect of Anion-Exchange-Treated Water Containing Phosphonic Acid and Benzotriazole on Copper Corrosion Resistance. Open Journal of Composite Materials, 16, 73-84.
https://doi.org/10.4236/ojcm.2026.163005
[12]  Yamada, Y., Seri, O., Tagashira, K. and Nagata, K. (1993) Effect of Cl? on the Pitting Corrosion of Copper in a Phosphonic Acid Solution. Journal of the Surface Finishing Society of Japan, 44, 753-756.
https://doi.org/10.4139/sfj.44.753
[13]  Kano, Y., Ikeda, I., Iyasu, T., Yamaguchi, Y., Yamada, Y. and Sakurada, O. (2022) Relationship between Corrosion Form and Elution Behavior of Copper Tubes Surfaces with Different Residual Carbon Amounts. Materials Sciences and Applications, 13, 595-602.
https://doi.org/10.4236/msa.2022.1312037
[14]  Aoyama, R., Takahashi, F., Sugiura, K., Arima, Y., Sakurada, O., Iyasu, T., Yamada, Y., Kawauchi, Y. and Itagaki, M. (2025) Effect of Scale Dispersants and Chloride Ion on Copper Pitting Corrosion in the Presence of Corrosion Inhibitors. Journal of Japan Institute of Copper, 64, 194-198.
https://doi.org/10.34562/jic.64.1_194
[15]  Ikeda, I., Kano, Y., Sasaki, T., Yamaguchi, Y., Imaizumi, Y., Tanaka, N., Yamada, Y. and Sakurada, O (2023) Comparison and Evaluation between the Rapid Evaluation Test and the Field Evaluation for Assessing the Pitting Corrosion Resistance of Copper Tube. Journal of Japan Institute of Copper, 62, 90-94.
https://doi.org/10.34562/jic.62.1_90
[16]  Takahashi, F., Sugiura, K., Aoyama, R., Sakurada, O., Ikeda, I., Kuratani, M., Tanaka, N., Yamada, T., Kawauchi, Y. and Itagaki, M. (2025) Effect of Carbon Film on Copper Tubes Pitting Corrosion in the Presence of Scale Dispersants and Corrosion Inhibitors. Journal of Japan Institute of Copper, 64, 204-208.
https://doi.org/10.34562/jic.64.1_204

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133