Fluorescence sensor arrays built on lanthanide metal-organic frameworks (Ln-MOFs) have rapidly become a standard approach for discriminating structurally similar analytes. These range from antibiotic congeners and their metabolites to co-occurring metal ions in food and biological matrices. The typical workflow pairs multi-channel fluorescence titration with principal component analysis (PCA) or hierarchical cluster analysis (HCA). A visually separated score plot is then routinely presented as sufficient evidence of discriminatory power. This paper audits that convention across the recent Ln-MOF sensor array literature. We identify five recurring evidentiary gaps. First, circular validation: a model is tested only on the data used to build it. Second, the absence of a quantitative separation metric to replace descriptive language such as “well separated”. Third, a concentration-dependence blind spot, where discrimination is demonstrated at a single analyte concentration rather than across the working range. Fourth, the near-total absence of robustness testing under simulated noise or real-world perturbation. Fifth, the conflation of classification claims with quantification claims that are rarely separately validated. Drawing on studies that have already addressed one or more of these gaps individually, we show that closing them requires no new sensing chemistry. Only a different treatment of data most studies already collect is needed. We propose a nine-item minimum reporting checklist and illustrate it against two representative published arrays. We argue for its adoption as a low-cost first step toward comparable, reproducible discrimination claims, drawing an explicit parallel to earlier minimum-reporting movements such as MIQE and STARD.
References
[1]
Xie, R., Yang, P., Liu, J., Zou, X., Tan, Y., Wang, X., et al. (2021) Lanthanide-Functionalized Metal-Organic Frameworks Based Ratiometric Fluorescent Sensor Array for Identification and Determination of Antibiotics. Talanta, 231, Article ID: 122366. https://doi.org/10.1016/j.talanta.2021.122366
[2]
Wang, X., Gopalsamy, K., Clavier, G., Maurin, G., Ding, B., Tissot, A., et al. (2024) Lanthanide MOF-Based Luminescent Sensor Arrays for the Detection of Castration-Resistant Prostate Cancer Curing Drugs and Biomarkers. ChemicalScience, 15, 6488-6499. https://doi.org/10.1039/d3sc06899d
[3]
Yin, K., Wu, S., Zheng, H., Gao, L., Liu, J., Yang, C., et al. (2021) Lanthanide Metal-Organic Framework-Based Fluorescent Sensor Arrays to Discriminate and Quantify Ingredients of Natural Medicine. Langmuir, 37, 5321-5328. https://doi.org/10.1021/acs.langmuir.1c00412
[4]
Zhang, W., Sun, J., Li, X., Wang, S., Zhang, W., Gong, Y., et al. (2025) Lanthanide MOF-Based Luminescent Sensor Array for Detection and Identification of Contaminants in Water and Biomarkers. Talanta, 281, Article ID: 126853. https://doi.org/10.1016/j.talanta.2024.126853
[5]
Shi, X., Wu, Y., Hu, G. and Li, Y. (2025) Machine Learning-Assisted Lanthanide Fluorescence Sensor Array Based on Ph Regulation for Pattern Recognition of Metal Ions in Biological Fluids. TheJournalofPhysicalChemistryC, 129, 12437-12449. https://doi.org/10.1021/acs.jpcc.5c03409
[6]
Yue, X., Fu, L., Li, Y., Xu, S., Lin, X. and Bai, Y. (2023) Lanthanide Bimetallic MOF-Based Fluorescent Sensor for Sensitive and Visual Detection of Sulfamerazine and Malachite. FoodChemistry, 410, Article ID: 135390. https://doi.org/10.1016/j.foodchem.2023.135390
[7]
Gao, G., Wang, L., Wang, X., Zhang, X., Lai, X., Yang, Q., et al. (2026) A Dual-Emission Ln-MOF as Ratiometric Fluorescence Sensor for Detecting NF and OTC with High Sensitivity and Selectivity. SpectrochimicaActaPartA: MolecularandBiomolecularSpectroscopy, 345, Article ID: 126831. https://doi.org/10.1016/j.saa.2025.126831
[8]
Chen, S.Y., Ye, J.T., Wang, L.Y., Lin, Y., Gong, Y.R., Xiao, M.D., et al. (2026) Lanthanide Metal-Organic Framework Fluorescent Sensor for the Detection of Furazolidone in Tap Water and Animal Feed. InorganicChemistry, 65, 5214-5221. https://doi.org/10.1021/acs.inorgchem.6c00129
[9]
Yue, X., Wu, C., Zhou, Z., Fu, L. and Bai, Y. (2022) Fluorescent Sensing of Ciprofloxacin and Chloramphenicol in Milk Samples via Inner Filter Effect and Photoinduced Electron Transfer Based on Nanosized Rod-Shaped Eu-MOF. Foods, 11, Article 3138. https://doi.org/10.3390/foods11193138
[10]
Zhang, H., Ma, L., Ma, F.L., Wang, X.F., Wang, L.L. and Wang, D.Z. (2025) Design of “Turn-Off” Luminescent 3D Ln-MOFs for Sensitive Detection of Fe3+ and Cr2O72?. JournalofMolecularStructure, 1335, Article ID: 141979. https://doi.org/10.1016/j.molstruc.2025.141979
[11]
Zhou, Y., Jiang, Y., Chen, X., Long, H., Zhang, M., Tang, Z., et al. (2024) Enhanced Sensitivity and Accuracy of Tb3+-Functionalized Zirconium-Based Bimetallic MOF for Visual Detection of Malachite Green in Fish. Foods, 13, Article 2855. https://doi.org/10.3390/foods13172855
[12]
Sharma, P. and Siddiqui, K.A. (2025) Metal-Organic Frameworks as Fluorescent and Colorimetric Sensors for Antibiotic Tracing. DiscoverChemistry, 2, Article No. 199. https://doi.org/10.1007/s44371-025-00282-0
[13]
Zhang, Y., Li, C., Jiang, M., Liu, Y. and Sun, Z. (2025) Advancements and Prospects of Metal-Organic Framework-Based Fluorescent Sensors. Biosensors, 15, Article 709. https://doi.org/10.3390/bios15110709
[14]
Chen, X. and Wang, Q. (2026) Recent Advances of Optical Sensing Arrays (2019-2025): From Design of Optical Elements to Multidimensional Analysis for Applications. AnalyticalChemistry, 98, 2633-2679. https://doi.org/10.1021/acs.analchem.5c05597
[15]
Zhou, X., Xie, C., Ye, L. and Ding, B. (2026) Smart Porous-Framework Sensor Arrays: Design Principles, AI-Driven Performance and Multiscenario Precision Detection. CoordinationChemistryReviews, 549, Article ID: 217306. https://doi.org/10.1016/j.ccr.2025.217306
[16]
Chi, J., Qin, Y., Song, Y. and Feng, L. (2025) Single-Component Dual-Emissive MOF Sensor Array for Fingerprint Identification of Multiplex Antibiotics. Analytical Chemistry, 97, 18299-18307. https://doi.org/10.1021/acs.analchem.5c03414
[17]
Xia, Y.F., Yu, X.S., Wen, S.T., Yuan, H.Q., Xu, C.C., Yang, L., et al. (2025) A Facile and Stable Single-System Fluorescent Sensor Array for the Quantification and Discrimination of Nitrofuran Antibiotics. FoodChemistry, 494, Article ID: 146136. https://doi.org/10.1016/j.foodchem.2025.146136
[18]
Wang, S., Xu, J., Yue, F., Zhang, L., Jia, L. and Zhao, T. (2025) Lanthanide-Empowered 3D-Printed Smartphone Interfacing Device Realizes Point-of-Care Discrimination of Multiple Fluoroquinolone Antibiotics in Aquatic Environments. SensorsandActuatorsB: Chemical, 443, Article ID: 138258. https://doi.org/10.1016/j.snb.2025.138258
[19]
Lei, M., Ge, F., Gao, X., Shi, Z. and Zheng, H. (2021) A Water-Stable Tb-MOF as a Rapid, Accurate, and Highly Sensitive Ratiometric Luminescent Sensor for the Discriminative Sensing of Antibiotics and D2O in H2O. InorganicChemistry, 60, 10513-10521. https://doi.org/10.1021/acs.inorgchem.1c01145
[20]
Lian, X., Chen, F., Li, Y., Zhang, R., Niu, H. and Zhang, Z. (2026) A Smartphone-Read, Machine Learning-Enhanced Lanthanide Hydrogel Sensor for Multimodal and On-Site Detection of Kanamycin in Food Safety. AnalyticalChemistry, 98, 3239-3251. https://doi.org/10.1021/acs.analchem.5c07000
[21]
Leng, Y., Zhang, J., Xu, T., Ma, Y., Luo, H., Huo, D., et al. (2026) A Triple-Channel Fluorescent Sensor Array Based on R6G@Eu-MOF for Baijiu Discrimination. MicrochemicalJournal, 226, Article ID: 118455. https://doi.org/10.1016/j.microc.2026.118455
[22]
Yuan, P.X., Wang, Y.P., Du, F., Yang, L.P. and Wang, L.L. (2025) Ratiometric Fluorescence Sensing and Discrimination of Tetracycline Analogs by Using Coumarin-Embedded Eu-MOF Nanosensor. Talanta, 281, Article ID: 126914. https://doi.org/10.1016/j.talanta.2024.126914
[23]
Esbensen, K.H. and Geladi, P. (2010) Principles of Proper Validation: Use and Abuse of Re-Sampling for Validation. JournalofChemometrics, 24, 168-187. https://doi.org/10.1002/cem.1310
[24]
Kennard, R.W. and Stone, L.A. (1969) Computer Aided Design of Experiments. Technometrics, 11, 137-148. https://doi.org/10.1080/00401706.1969.10490666
[25]
Du, S.Z., Sun, Z., Han, L., Qing, M., Luo, H.Q. and Li, N.B. (2020) Two 3d-4f Metal-Organic Frameworks as Fluorescent Sensor Array for the Discrimination of Phosphates Based on Different Response Patterns. SensorsandActuatorsB: Chemical, 324, Article ID: 128757. https://doi.org/10.1016/j.snb.2020.128757
[26]
Gao, Y., Zhu, Y., Wang, Y. and Bi, J. (2024) Water-Stable Ln-MOF as a Multi-Emitting Luminescent Sensor for the Detection of Metal Ions and Pharmaceuticals. SpectrochimicaActaPartA: MolecularandBiomolecularSpectroscopy, 323, Article ID: 124915. https://doi.org/10.1016/j.saa.2024.124915
[27]
He, X.Y., Wang, Y., Xue, Q., Qian, W.F., Li, G.L. and Li, Q. (2025) Molecularly Imprinted MOF Nanozymes: Demonstration of Smartphone-Integrated Dual-Mode Platform for Ratiometric Fluorescent/Colorimetric Detection of Chloramphenicol. FoodChemistry: X, 26, Article ID: 102322. https://doi.org/10.1016/j.fochx.2025.102322
[28]
Sun, Y.X., Ji, B.T., Chen, J.H., Liu, L.P., Gao, L.L., Deng, Z.P., et al. (2025) A Smartphone-Integrated Bimetallic Ratiometric Fluorescent Probe for Specific Visual Detection of Tetracycline Antibiotics in Food Samples and Latent Fingerprinting. FoodChemistry, 464, Article ID: 141782. https://doi.org/10.1016/j.foodchem.2024.141782
[29]
Zhang, W., Zhao, Y., Sun, J., Peng, D., Li, X., Lv, Y., et al. (2024) Fluorescent Sensors Based on Lanthanide-Based Metal-Organic Frameworks via Devices and Ph Response. InorganicChemistry, 63, 15527-15536. https://doi.org/10.1021/acs.inorgchem.4c02795
[30]
Thompson, M., Ellison, S.L.R. and Wood, R. (2002) Harmonized Guidelines for Single-Laboratory Validation of Methods of Analysis (IUPAC Technical Report). PureandAppliedChemistry, 74, 835-855. https://doi.org/10.1351/pac200274050835
[31]
Bustin, S.A., Benes, V., Garson, J.A., Hellemans, J., Huggett, J., Kubista, M., et al. (2009) The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments. ClinicalChemistry, 55, 611-622. https://doi.org/10.1373/clinchem.2008.112797
[32]
Bossuyt, P.M., Reitsma, J.B., Bruns, D.E., Gatsonis, C.A., Glasziou, P.P., Irwig, L., et al. (2015) STARD 2015: An Updated List of Essential Items for Reporting Diagnostic Accuracy Studies. BMJ, 35, h5527. https://doi.org/10.1136/bmj.h5527
[33]
Taylor, C.F., Field, D., Sansone, S.A., Aerts, J., Apweiler, R., Ashburner, M., et al. (2008) Promoting Coherent Minimum Reporting Guidelines for Biological and Biomedical Investigations: The MIBBI Project. NatureBiotechnology, 26, 889-896. https://doi.org/10.1038/nbt.1411