The purpose of this study is to compare the reliability of manual muscle testing (MMT) for hip external rotation (ER) in the side-lying (SL) and seated positions. The SL position aligns hip ER testing with current clinical practice and may allow greater contribution from the piriformis during strength assessment in physical therapy. Hip external rotator strength of 18 subjects was measured using a handheld dynamometer (HHD) placed 3 cm above the medial malleolus in both seated and SL positions. Tibial and femoral lengths were recorded to calculate torque for each position. Inter- and intra-rater reliability were assessed using intraclass correlation coefficients (ICC). Across all three examiners, intra-rater reliability was consistently higher in the SL position, ranging from poor to excellent (ICC = 0.229 [95% CI ?0.072, 0.503], 0.811 [0.594, 0.909], 0.942 [0.889, 0.970]) compared to the seated position (ICC = 0.187 [?0.101, 0.463], 0.555 [0.271, 0.747], 0.739 [0.387, 0.881]). Inter-rater reliability was poor in both positions (seated ICC = 0.240 [0.006, 0.563]; SL ICC = 0.234 [0.003, 0.551]). These findings suggest that testing hip ER strength in the SL position poses similar reliability to assessment in the seated position. While inter-rater reliability was determined to be poor for both testing positions, some examiners were found to have increased intra-rater reliability in the SL position. The SL position aligns resistance against gravity, improves objective strength measurement, enhances isolation of the external rotators, increases contribution from all ER muscles, and reduces hip flexor compensation seen in seated testing. Reliable assessment of these muscles is important for injury prevention and rehabilitation, so the SL position can be considered an equally reliable way to assess hip ER strength clinically.
References
[1]
Bazett-Jones, D.M. and Squier, K. (2020) Measurement Properties of Hip Strength Measured by Handheld Dynamometry: Reliability and Validity across the Range of Motion. Physical Therapy in Sport, 42, 100-106. https://doi.org/10.1016/j.ptsp.2020.01.005
[2]
Soomro, R.R., Karimi, H. and Gillani, S.A. (2022) Reliability of Hand-Held Dynamometer in Measuring Gluteus Medius Isometric Muscle Strength in Healthy Population. Pakistan Journal of Medical Sciences, 38, 1238-1242. https://doi.org/10.12669/pjms.38.5.5207
[3]
Waiteman, M.C., Garcia, M.C., Briani, R.V., Norte, G., Glaviano, N.R., De Azevedo, F.M., et al. (2023) Can Clinicians Trust Objective Measures of Hip Muscle Strength from Portable Dynamometers? A Systematic Review with Meta-Analysis and Evidence Gap Map of 107 Studies of Reliability and Criterion Validity Using the COSMIN Methodology. Journal of Orthopaedic & Sports Physical Therapy, 53, 655-672. https://doi.org/10.2519/jospt.2023.12045
[4]
Byrne, A., Lodge, C. and Wallace, J. (2020) Intrarater Test-Retest Reliability of Hip Abduction, Internal Rotation, and External Rotation Strength Measurements in a Healthy Cohort Using a Handheld Dynamometer and a Portable Stabilization Device: A Pilot Study. Archives of Rehabilitation Research and Clinical Translation, 2, Article ID: 100050. https://doi.org/10.1016/j.arrct.2020.100050
[5]
Glaviano, N.R. and Bazett-Jones, D.M. (2021) The Influence of Sagittal Plane Hip Position on Lower-Extremity Muscle Activity and Torque Output. Journal of Sport Rehabilitation, 30, 573-581. https://doi.org/10.1123/jsr.2020-0268
[6]
Bloom, N. and Cornbleet, S.L. (2014) Hip Rotator Strength in Healthy Young Adults Measured in Hip Flexion and Extension by Using a Hand-Held Dynamometer. PM&R, 6, 1137-1142. https://doi.org/10.1016/j.pmrj.2014.06.002
[7]
Delp, S.L., Hess, W.E., Hungerford, D.S. and Jones, L.C. (1999) Variation of Rotation Moment Arms with Hip Flexion. Journal of Biomechanics, 32, 493-501. https://doi.org/10.1016/s0021-9290(99)00032-9
[8]
Yoo, T., Kim, S., Burland, J.P. and Glaviano, N.R. (2025) Reliability of Hand-Held Dynamometer in Measuring Gluteal Muscle Rate of Torque Development and Peak Torque: Push and Pull Configurations. International Journal of Sports Physical Therapy, 20, 595-605. https://doi.org/10.26603/001c.133550
[9]
Khayambashi, K., Ghoddosi, N., Straub, R.K. and Powers, C.M. (2016) Hip Muscle Strength Predicts Noncontact Anterior Cruciate Ligament Injury in Male and Female Athletes. The American Journal of Sports Medicine, 44, 355-361. https://doi.org/10.1177/0363546515616237
[10]
Xie, P., István, B. and Liang, M. (2022) The Relationship between Patellofemoral Pain Syndrome and Hip Biomechanics: A Systematic Review with Meta-Analysis. Healthcare, 11, Article No. 99. https://doi.org/10.3390/healthcare11010099
[11]
Reese, N.B. (2012) Muscle and Sensory Testing. 3rd Edition, Elsevier.
[12]
Hislop, H.J., Avers, D., Brown, M. and Daniels, L. (2014) Daniels and Worthingham’s Muscle Testing: Techniques of Manual Examination and Performance Testing. 9th Edition, Elsevier.
[13]
Naqvi, U., Margetis, K. and Sherman, A.L. (2025) Muscle Strength Grading. StatPearls Publishing. http://www.ncbi.nlm.nih.gov/books/NBK436008/
[14]
Conable, K.M. and Rosner, A.L. (2011) A Narrative Review of Manual Muscle Testing and Implications for Muscle Testing Research. Journal of Chiropractic Medicine, 10, 157-165. https://doi.org/10.1016/j.jcm.2011.04.001
[15]
Thorborg, K., Petersen, J., Magnusson, S.P. and H?lmich, P. (2010) Clinical Assessment of Hip Strength Using a Hand-Held Dynamometer Is Reliable. Scandinavian Journal of Medicine & Science in Sports, 20, 493-501. https://doi.org/10.1111/j.1600-0838.2009.00958.x
[16]
McNabb, K., Sánchez, M.B., Selfe, J., Reeves, N.D. and Callaghan, M. (2024) Handheld Dynamometry: Validity and Reliability of Measuring Hip Joint Rate of Torque Development and Peak Torque. PLOS ONE, 19, e0308956. https://doi.org/10.1371/journal.pone.0308956
[17]
Koo, T.K. and Li, M.Y. (2016) A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research. Journal of Chiropractic Medicine, 15, 155-163. https://doi.org/10.1016/j.jcm.2016.02.012