全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

基于磁导率锁定放大的高压输电线压接结构内部钢管探测
Internal Steel Pipe Detection in High-Voltage Transmission Line Compression Joints Based on Permeability Locked-In Amplification

DOI: 10.12677/jsta.2026.141009, PP. 93-100

Keywords: 高压输电线,锁定放大,磁导率,压接结构,无损探伤
High-Voltage Transmission Line
, Locked-In Amplification, Permeability, Compression Joint, Non-Destructive Testing

Full-Text   Cite this paper   Add to My Lib

Abstract:

为解决高压输电线压接结构内部钢管检测中X射线法设备笨重、存在辐射的难题,本文提出一种基于磁导率锁定放大的无损检测方法。设计了由硅钢铁芯和激励–检测线圈构成的专用磁导率探头,用于提取内部钢管的磁特性变化;开发了以正交锁定放大为核心的微弱信号处理电路,通过开关解调和低通滤波从强噪声背景中提取信号的正交分量,进而计算幅值与相位。以LGJ-400/35型输电线压接结构为对象的实验表明:该系统噪声低于50 mVpp,能清晰识别钢管位置,定位精度优于10 mm;所研制的便携系统总重仅2.9 kg,较传统X射线设备(通常13~40 kg)大幅减轻。本研究为高压输电线压接质量检测提供了一种轻量化、高精度的有效解决方案,有助于推动线路巡检自动化发展。
To address the challenges of heavy equipment and radiation exposure associated with X-ray inspection of internal steel pipes in high-voltage transmission line compression joints, this paper proposes a non-destructive testing method based on permeability locked-in amplification. A specialized permeability probe, consisting of a silicon steel core with excitation and detection coils, was designed to extract magnetic characteristic variations from the internal steel pipe. A weak signal processing circuit, centered on orthogonal lock-in amplification, was developed to extract the quadrature components of the signal from a high-noise background through switching demodulation and low-pass filtering, enabling the calculation of signal amplitude and phase. Experiments conducted on LGJ-400/35 transmission line compression joints demonstrated that the system exhibits noise below 50 mVpp, enables clear identification of the steel pipe location with a positioning accuracy better than 10 mm, and the developed portable system weighs only 2.9 kg, significantly less than traditional X-ray equipment (typically 13~40 kg). This research provides an effective, lightweight, and high-precision solution for quality inspection of high-voltage transmission line compression joints, facilitating the advancement of automated line inspection.

References

[1]  戴雨志, 牛雨欣, 张亢. 输电线路断线原因分析及防范措施[J]. 机械与电子控制工程, 2023, 5(9): 101-103.
[2]  Zeng, Z., Lv, J., Qu, S. and Shao, H. (2023) Simulation Analysis of Crimping Process of Strain Clamp-ACSR System. 2023 3rd International Conference on Intelligent Power and Systems (ICIPS), Shenzhen, 20-22 October 2023, 245-249.
https://doi.org/10.1109/icips59254.2023.10404168
[3]  惠宝军, 傅明利, 刘通, 等. 110 kV及以上电力电缆系统故障统计分析[J]. 南方电网技术, 2017, 11(12): 44-50+67.
[4]  杨梅芳. 基于磁导率检测技术的铁磁试件检测试验研究[D]: [硕士学位论文]. 南昌: 南昌航空大学, 2018.
[5]  Levin, A.A., Narykova, M.V., Lihachev, A.I., Kardashev, B.K., Kadomtsev, A.G., Prasolov, N.D., et al. (2022) Comparison of Structural, Microstructural, Elastic, and Microplastic Properties of the AAAC (A50) and ACSR (AC50/8) Cables after Various Operation Periods in Power Transmission Lines. Crystals, 12, Article 1267.
https://doi.org/10.3390/cryst12091267
[6]  Gao, Y., Song, G., Li, S., Zhen, F., Chen, D. and Song, A. (2020) LineSpyX: A Power Line Inspection Robot Based on Digital Radiography. IEEE Robotics and Automation Letters, 5, 4759-4765.
https://doi.org/10.1109/lra.2020.3003772
[7]  Pinto, A.V., Sebrao, M.Z., Lourenco, C.R.S., et al. (2010) Remote Detection of Internal Corrosion in Conductor Cables of Power Transmission Lines. 2010 1st International Conference on Applied Robotics for the Power Industry, Montreal, 5-7 October 2010, 1-6.
https://doi.org/10.1109/carpi.2010.5624453
[8]  程衍伟. 基于ARM的输电线电磁无损检测系统开发[D]: [硕士学位论文]. 南京: 南京航空航天大学, 2016.
[9]  Brahim, Y.I., Bellemare, J., Rousseau, G., et al. (2023) Ultrasensitive Lightweight Magnetic Probe for Non-Destructive Inspection of High-Voltage Overhead Lines. NDT & E International, 134, Article ID: 102781.
https://doi.org/10.1016/j.ndteint.2022.102781
[10]  彭放, 刘甜甜, 苏江文, 等. 基于X射线无损探伤的输电线路耐张线夹缺陷检测[J]. 机械制造与自动化, 2024, 53(4): 264-270.
[11]  王浩洋, 余快, 龚景阳, 等. 输电线路耐张导线金具压接质量检测方法现状与展望[J]. 电气技术, 2023, 24(4): 1-8.
[12]  邱公喆, 康宜华, 程偲, 等. 连续油管分层缺陷磁导率扰动电磁检测方法与检测系统[J]. 焊管, 2023, 46(5): 36-43.
[13]  朱艳生, 高勇, 吕乙松, 等. 微弱信号检测的锁相放大电路仿真[J]. 湖南文理学院学报(自然科学版), 2023, 35(1): 20-25.
[14]  邓明亮. 架空输电线路耐张管压接缺陷分析与质量检查[J]. 湖南电力, 2018, 38(3): 34-37.
[15]  陈家慧, 王方强, 兰贵天, 等. 耐张线夹防滑槽漏压的失效分析与机理研究[J]. 热加工工艺, 2022, 51(12): 146-150+155.
[16]  Ou, Z., Shu, Z., He, T., Xu, C., Cen, J. and Han, Z. (2024) A Weak Bias-Magnetized Dynamic Permeability Testing Method for Detecting and Distinguishing Inner and Outer Diameter Defects in Gas Pipelines. NDT & E International, 151, Article ID: 103284.
https://doi.org/10.1016/j.ndteint.2024.103284
[17]  Zhang, Y., Hu, D., Chen, J. and Yin, L. (2023) Research on Non-Destructive Testing of Stress in Ferromagnetic Components Based on Metal Magnetic Memory and the Barkhausen Effect. NDT & E International, 138, Article ID: 102881.
https://doi.org/10.1016/j.ndteint.2023.102881

Full-Text

Contact Us

service@oalib.com

QQ:3279437679