Designing hybrid power plants is a crucial aspect of deploying energy sources in remote rural areas far from the power grid. Many studies have been conducted on this topic. However, there is a lack of information on the process of commissioning and evaluating the performance of these plants, specifically for photovoltaic-diesel hybrids. The suggested approach involves conducting three types of tests: “generator only”, “multi-generator”, and “hybrid”. The methodology helps investigate the behaviour and performance of generators, load distribution and current quality. It was implemented in a hybrid PV/diesel plant in Burkina Faso, where it revealed technical shortcomings that hindered optimal performance. The power output of the Diesel generators deviated from the manufacturer’s specifications, with diesel generators only producing 65 - 80% of their rated capacity during testing. Moreover, a malfunction in the voltage regulator of Diesel generator 2 prevented it from operating in parallel with the others. The photovoltaic arrays, however, operated efficiently, maintaining an average global efficiency of around 83%. In terms of protection, testing revealed that a reverse power relay is needed to protect each diesel generator, as it may be damaged by reversed power. It is crucial to mention that the EN 50,160 standard’s electrical quality requirements were fully met, with total harmonic distortion consistently below 8%. This methodology may serve as a guide for commissioning rural hybrid power plants in sub-Saharan Africa and other regions.
References
[1]
Schneider, N. (2021) Population Growth, Electricity Demand and Environmental Sustainability in Nigeria: Insights from a Vector Auto-Regressive Approach. International Journal of Environmental Studies, 79, 149-176. https://doi.org/10.1080/00207233.2021.1905317
[2]
Hlongwane, N.W. and Daw, O.D. (2023) Electricity Consumption and Population Growth in South Africa: A Panel Approach. International Journal of Energy Economics and Policy, 13, 374-383. https://doi.org/10.32479/ijeep.13044
[3]
Ndukwu, J. (2025) Population Dynamics, Energy Consumption and Economic Growth in Sub-Saharan African. International Journal of Economics and Financial Management, 10, 41-57.
[4]
Brew-Hammond, A. (2010) Energy Access in Africa: Challenges Ahead. Energy Policy, 38, 2291-2301. https://doi.org/10.1016/j.enpol.2009.12.016
[5]
Mohammed, Y.S., Mustafa, M.W. and Bashir, N. (2014) Hybrid Renewable Energy Systems for Off-Grid Electric Power: Review of Substantial Issues. Renewable and Sustainable Energy Reviews, 35, 527-539. https://doi.org/10.1016/j.rser.2014.04.022
[6]
Natividad, L.E. and Benalcazar, P. (2023) Hybrid Renewable Energy Systems for Sustainable Rural Development: Perspectives and Challenges in Energy Systems Modeling. Energies, 16, Article 1328. https://doi.org/10.3390/en16031328
[7]
Vincent, S.A., Tahiru, A., Lawal, R.O., Aralu, C.E. and Okikiola, A.Q. (2024) Hybrid Renewable Energy Systems for Rural Electrification in Developing Countries: Assessing Feasibility, Efficiency, and Socioeconomic Impact. World Journal of Advanced Research and Reviews, 24, 2190-2204. https://doi.org/10.30574/wjarr.2024.24.2.3515
[8]
El-Hefnawi, S.H. (1998) Photovoltaic Diesel-Generator Hybrid Power System Sizing. Renewable Energy, 13, 33-40. https://doi.org/10.1016/s0960-1481(97)00074-8
[9]
El-Shafy A. Nafeh, A. (2010) Proposed Technique for Optimally Sizing a PV/Diesel Hybrid Systems. Renewable Energy and Power Quality Journal, 1, 1572-1577. https://doi.org/10.24084/repqj08.727
[10]
Khatib, T., Mohamed, A., Sopian, K. and Mahmoud, M. (2011) Optimal Sizing of Building Integrated Hybrid PV/Diesel Generator System for Zero Load Rejection for Malaysia. Energy and Buildings, 43, 3430-3435. https://doi.org/10.1016/j.enbuild.2011.09.008
[11]
Yamegueu, D., Azoumah, Y., Py, X. and Zongo, N. (2011) Experimental Study of Electricity Generation by Solar PV/Diesel Hybrid Systems without Battery Storage for Off-Grid Areas. Renewable Energy, 36, 1780-1787. https://doi.org/10.1016/j.renene.2010.11.011
[12]
Tsuanyo, D., Aussel, D., Azoumah, Y. and Neveu, P. (2015) Optimal Design of a PV/Diesel Hybrid System for Decentralized Areas through Economic Criteria. World Academy of Science, Engineering and Technology, International Journal of Computer, ElectricalAutomation, Control and Information Engineering, 9, 486-491.
[13]
Koucoi, G. (2016) Energy Management Strategies for Hybrid Pv/Diesel Energy Systems: Simulation and Experimental Validation. International Journal of Energy and Power Engineering, 5, 6-14. https://doi.org/10.11648/j.ijepe.20160501.12
[14]
Gharib, M.R. and Mohammadbeigi, A. (2025) Optimal Sizing, Techno-Economic, and Environmental Assessment of Hybrid Renewable Energy Systems. Energy Strategy Reviews, 59, Article ID: 101721. https://doi.org/10.1016/j.esr.2025.101721
[15]
Nain, D. and Kumar, D. (2021) Performance Analysis of Hybrid PV/Diesel Power Generation System with Battery Storage. International Journal for Scientific Research & Development, 9, 98-106.
[16]
Ramli, M.A.M., Hiendro, A. and Bouchekara, H.R.E.H. (2014) Performance Analysis of Hybrid PV/Diesel Energy System in Western Region of Saudi Arabia. International Journal of Photoenergy, 2014, Article ID: 626251. https://doi.org/10.1155/2014/626251
[17]
Azman, N. and Sulistiawan, R. (2024) Design and Performance Evaluation of an Off-Grid Hybrid Solar System in a Remote Location: A Case Study of Legundi Island. MethodsX, 12, Article ID: 102716. https://doi.org/10.1016/j.mex.2024.102716
[18]
Brahim, B. (2018) Performance Investigation of a Hybrid PV-Diesel Power System for Remote Areas. International Journal of Energy Research, 43, 1019-1031. https://doi.org/10.1002/er.4301
[19]
Yamegueu, D., Nelson, H.T. and Boly, A.S. (2024) Improving the Performance of PV/Diesel Microgrids via Integration of a Battery Energy Storage System: The Case of Bilgo Village in Burkina Faso. Energy, Sustainability and Society, 14, Article No. 48. https://doi.org/10.1186/s13705-024-00480-1
[20]
Richmond, J., Agrawal, S. and Urpelainen, J. (2020) Drivers of Household Appliance Usage: Evidence from Rural India. Energy for Sustainable Development, 57, 69-80. https://doi.org/10.1016/j.esd.2020.05.004
[21]
Isihak, S., Akpan, U. and Ohiare, S. (2020) The Evolution of Rural Household Electricity Demand in Grid-Connected Communities in Developing Countries: Result of a Survey. Future Cities and Environment, 6, 1-11. https://doi.org/10.5334/fce.96
[22]
Tamele, B.Z.S., Wassie, Y.T., Tsamba, A.J. and Ahlgren, E.O. (2025) Electricity Consumption and Its Determinants in Rural Mozambique—At the Edge of the Electricity Grid. Energy for Sustainable Development, 85, Article ID: 101662. https://doi.org/10.1016/j.esd.2025.101662
[23]
Lee, K.Y., Park, Y.M. and Ortiz, J.L. (1984) Fuel-Cost Minimisation for Both Real-And Reactive-Power Dispatches. IEE Proceedings C Generation, Transmission and Distribution, 131, 85-93. https://doi.org/10.1049/ip-c.1984.0012
[24]
Zhang, W., Li, F. and Tolbert, L.M. (2007) Review of Reactive Power Planning: Objectives, Constraints, and Algorithms. IEEE Transactions on Power Systems, 22, 2177-2186. https://doi.org/10.1109/tpwrs.2007.907452
[25]
Saqib, M.A. and Saleem, A.Z. (2015) Power-quality Issues and the Need for Reactive-Power Compensation in the Grid Integration of Wind Power. Renewable and Sustainable Energy Reviews, 43, 51-64. https://doi.org/10.1016/j.rser.2014.11.035
[26]
Goh, H.H., Sim, S.Y., Abd Samat, M.N., Mohamed, A.M., Ling, C.W., Chua, Q.S., et al. (2017) Loss of Excitation (LOE) Protection of Synchronous Generator. Indonesian Journal of Electrical Engineering and Computer Science, 8, Article 230. https://doi.org/10.11591/ijeecs.v8.i1.pp230-236
[27]
Issa, M., Ibrahim, H., Hosni, H., Ilinca, A. and Rezkallah, M. (2020) Effects of Low Charge and Environmental Conditions on Diesel Generators Operation. Eng, 1, 137-152. https://doi.org/10.3390/eng1020009
[28]
Marqusee, J. and Jenket, D. (2020) Reliability of Emergency and Standby Diesel Generators: Impact on Energy Resiliency Solutions. Applied Energy, 268, Article ID: 114918. https://doi.org/10.1016/j.apenergy.2020.114918
[29]
Barbosa, R., Issa, M., Silva, S. and Ilinca, A. (2022) Variable Speed Diesel Electric Generators: Technologies, Benefits, Limitations, Impact on Greenhouse Gases Emissions and Fuel Efficiency. Journal of Energy and Power Technology, 4, 1-21. https://doi.org/10.21926/jept.2201003
[30]
Winardi, B. and Nugroho, A. (2022) Study of Generator Set Overload Protection System in Power Generation Units. International Journal of Research in Vocational Studies (IJRVOCAS), 1, 11-15. https://doi.org/10.53893/ijrvocas.v1i4.67
[31]
Ghorbanzadeh, M., Issa, M. and Ilinca, A. (2023) Experimental Underperformance Detection of a Fixed-Speed Diesel-Electric Generator Based on Exhaust Gas Emissions. Energies, 16, Article 3537. https://doi.org/10.3390/en16083537
[32]
Khaled, M. (2024) Enhancing Diesel Generators Power and Fuel Consumption Using Thermoelectric Generators and Exhaust Air of HVAC Systems. International Journal of Thermofluids, 24, Article ID: 100969. https://doi.org/10.1016/j.ijft.2024.100969
[33]
Dedes, E.K., Hudson, D.A. and Turnock, S.R. (2012) Assessing the Potential of Hybrid Energy Technology to Reduce Exhaust Emissions from Global Shipping. Energy Policy, 40, 204-218. https://doi.org/10.1016/j.enpol.2011.09.046
[34]
Rangel, N., Li, H. and Aristidou, P. (2023) An Optimisation Tool for Minimising Fuel Consumption, Costs and Emissions from Diesel-PV-Battery Hybrid Microgrids. Applied Energy, 335, Article ID: 120748. https://doi.org/10.1016/j.apenergy.2023.120748
[35]
Stiel, A. and Skyllas-Kazacos, M. (2012) Feasibility Study of Energy Storage Systems in Wind/Diesel Applications Using the HOMER Model. Applied Sciences, 2, 726-737. https://doi.org/10.3390/app2040726
[36]
Kiray, V., Orhan, M. and Chijioke, J.N. (2021) Significant Increase in Fuel Efficiency of Diesel Generators with Lithium-Ion Batteries Documented by Economic Analysis. Energies, 14, Article 6904. https://doi.org/10.3390/en14216904
[37]
Hossain, M.J., Pota, H.R., Ugrinovskii, V. and Ramos, R.A. (2009) Excitation Control for Large Disturbances in Power Systems with Dynamic Loads. 2009 IEEE Power & Energy Society General Meeting, Calgary, 26-30 July 2009, 1-8. https://doi.org/10.1109/pes.2009.5275909
[38]
Zhou, B.R., Yao, W.F., Xu, T., Dong, Y.P. and Xie, X.R. (2015) Investigating the Influence of Types and Parameters of Excitation Systems on the Dynamic Reactive Power Reserve of Synchronous Generators. 2015 12th International Conference on Fuzzy Systems and Knowledge Discovery (FSKD), Zhangjiajie, 15-17 August 2015, 2432-2436. https://doi.org/10.1109/fskd.2015.7382335
[39]
Yamegueu, D., Azoumah, Y., Py, X. and Kottin, H. (2013) Experimental Analysis of a Solar PV/Diesel Hybrid System without Storage: Focus on Its Dynamic Behavior. International Journal of Electrical Power & Energy Systems, 44, 267-274. https://doi.org/10.1016/j.ijepes.2012.07.027
[40]
Dei, T. and Batjargal, N. (2022) Technical and Economical Evaluation of Micro-Solar PV/Diesel Hybrid Generation System for Small Demand. International Journal of Renewable Energy Development, 11, 1101-1112. https://doi.org/10.14710/ijred.2022.46747