全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Combined FET and TEVAR via the Ascending Aorta for Complex Aortic Arch Aneurysms

DOI: 10.4236/wjcs.2025.157016, PP. 165-172

Keywords: Frozen Elephant Trunk, TEVAR, Aortic Arch Aneurysm, Hybrid Aortic Repair, Antegrade Access

Full-Text   Cite this paper   Add to My Lib

Abstract:

The Frozen Elephant Trunk (FET) technique using the FROZENIX J-graft simplifies total arch replacement but poses challenges in patients with anatomically complex aortas. We report two cases of simultaneous ascending and aortic arch replacement using FROZENIX and thoracic endovascular aortic repair (TEVAR) via the ascending aorta in such anatomically challenging cases. Case 1: A 78-year-old man with a prior Y-graft replacement and TEVAR for abdominal aortic aneurysm presented with a tortuous descending aorta, which made device advancement difficult. He underwent successful total arch replacement using FROZENIX combined with TEVAR via the ascending aorta. Case 2: A 77-year-old man with chronic renal failure and a large aortic arch aneurysm underwent the same combined procedure with favorable results. Both patients recovered without neurological or renal complications and were discharged in stable condition. Simultaneous FET and TEVAR via the ascending aorta may offer a viable single-stage alternative for high-risk or anatomically complex cases.

References

[1]  Ius, F., Fleissner, F., Pichlmaier, M., Karck, M., Martens, A., Haverich, A., et al. (2013) Total Aortic Arch Replacement with the Frozen Elephant Trunk Technique: 10-Year Follow-Up Single-Centre Experience. European Journal of Cardio-Thoracic Surgery, 44, 949-957.
https://doi.org/10.1093/ejcts/ezt229
[2]  Okita, Y. (2020) Frozen Elephant Trunk with Frozenix Prosthesis. Annals of Cardiothoracic Surgery, 9, 152-163.
https://doi.org/10.21037/acs.2020.03.13
[3]  Tamura, K., Nomura, F., Mukai, S. and Ihara, K. (2002) Pitfalls in Open Stent Grafting for Distal Aortic Arch Aneurysm. Japanese Journal of Cardiovascular Surgery, 31, 139-142.
https://doi.org/10.4326/jjcvs.31.139
[4]  Tsagakis, K., Pacini, D., Di Bartolomeo, R., Benedik, J., Cerny, S., Gorlitzer, M., et al. (2011) Arch Replacement and Downstream Stent Grafting in Complex Aortic Dissection: First Results of an International Registry. European Journal of Cardio-Thoracic Surgery, 39, 87-94.
https://doi.org/10.1016/j.ejcts.2010.03.070
[5]  Lee, J.H. and Park, K.H. (2019) Endovascular Aneurysm Repair by Combining Different Endografts: The Zenith Body and Endurant Limbs. Vascular Specialist International, 35, 10-15.
https://doi.org/10.5758/vsi.2019.35.1.10
[6]  Nomura, Y., Tonoki, S., Kawashima, M., Fujisue, J., Uchino, G., Miyahara, S., et al. (2021) Distal Stent Graft-Induced New Entry after Total Arch Replacement with Frozen Elephant Trunk for Aortic Dissection. Annals of Vascular Diseases, 14, 362-367.
https://doi.org/10.3400/avd.oa.21-00105
[7]  Takagaki, M., Midorikawa, H., Yamaguchi, H., Nakamura, H., Kadowaki, T., Ueno, Y., et al. (2020) Rapidly Progressed Distal Arch Aneurysm with Distal Open Stent Graft-Induced New Entry Caused by “Spring-Back” Force. Annals of Vascular Diseases, 13, 343-346.
https://doi.org/10.3400/avd.cr.20-00075

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133