Factors Affecting Continuous Glucose Monitoring Results: A Meta-Analysis

DOI: 10.4236/jdm.2025.153008, PP. 107-120

Keywords: Diabetic Patients, Continuous Dynamic Blood Glucose Monitoring, Influence

Full-Text   Cite this paper   Add to My Lib

Abstract:

Since its introduction, continuous glucose monitoring (CGM) has achieved good benefits in clinical blood glucose monitoring and self-blood glucose management for diabetic patients. However, during the usage process, there are various interfering factors, among which there are more or less controversial ones. This study evaluated the impact of these factors on the accuracy of continuous glucose monitoring (CGM). A meta-analysis was conducted on a type of observational study that used continuous glucose monitoring (CGM) to monitor blood glucose levels in individuals diagnosed with or undiagnosed for diabetes. A total of 526 articles were retrieved from four electronic databases. By using EndNeto software to exclude ineligible data, 425 articles were eliminated. For the remaining 101 articles, information such as the title, author, and publication year of each document was entered into the system, which automatically identified and excluded 14 duplicate studies. In the end, the remaining 87 articles were carefully reviewed. Of these 87 studies: 17 were animal experiments, 31 involved research on individuals under 18 years old, 14 were missing articles, and 15 were reviews. Ultimately, 11 studies met our requirements for analysis. The results of the heterogeneity test showed that the data was heterogeneous (χ2: 3438.01, I2 = 99.7%, p = 0.266 > 0.05). Statistical analysis was conducted using the fixed-effect model, and there was no publication bias. It is indicated that with the continuous update of science and technology, fewer and fewer factors that are considered likely to affect the results of continuous dynamic blood glucose monitoring will be reduced and eliminated. As a result, more advanced, convenient, efficient and accurate continuous dynamic blood glucose monitoring methods will benefit humanity. To provide an effective basis for accurately judging the blood glucose levels of diabetic patients, and to offer effective guidance for patients in aspects such as correct exercise, diet control, and pancreatic islet use in blood glucose self-management.

References

[1]  Harreiter, J. and Roden, M. (2023) Diabetes Mellitus—Definition, Klassifikation, Diagnose, Screening Und Prävention (Update 2023). Wiener klinische Wochenschrift, 135, 7-17.
https://doi.org/10.1007/s00508-022-02122-y
[2]  Inoue, K., Liu, M., Aggarwal, R., Marinacci, L.X. and Wadhera, R.K. (2025) Prevalence and Control of Diabetes among US Adults, 2013 to 2023. Journal of the American Medical Association, 333, 1255-1257.
https://doi.org/10.1001/jama.2024.28513
[3]  Chinese Diabetes Society and Chinese Medical Association (2025) Guidelines for the Prevention and Treatment of Diabetes in China (2024 Edition). Chinese Journal of Diabetes, 17, 136-139.
[4]  Chinese Diabetes Society and Chinese Medical Association (2021) Clinical Application Guidelines for Blood Glucose Monitoring in China (2021 Edition). Chinese Journal of Diabetes, 13, 936-948.
[5]  Liu, Y.X. (2023) Development and Challenges of Wearable Flexible Continuous Glucose Monitoring Technology. Application of Electronic Technology, 12, 75-84.
[6]  Yang, M. (2023) Clinical Application and Research Progress of Continuous Glucose Monitoring Systems. Chinese Journal of Practical Internal Medicine, 8, 688-693.
[7]  Sun, Z., Du, Y., Wang, S., Sun, S., Ye, Y., Sun, X., et al. (2024) Accuracy of Freestyle Libre Flash Glucose Monitoring in Patients with Type 2 Diabetes Who Migrated from Highlands to Plains. World Journal of Diabetes, 15, 1254-1262.
https://doi.org/10.4239/wjd.v15.i6.1254
[8]  Hanson, K., Kipnes, M. and Tran, H. (2024) Comparison of Point Accuracy between Two Widely Used Continuous Glucose Monitoring Systems. Journal of Diabetes Science and Technology, 18, 598-607.
https://doi.org/10.1177/19322968231225676
[9]  Avari, P., Tang, W., Jugnee, N., Hersi, I., Al-Balah, A., Tan, T., et al. (2023) The Accuracy of Continuous Glucose Sensors in People with Diabetes Undergoing Hemodialysis (ALPHA Study). Diabetes Technology & Therapeutics, 25, 447-456.
https://doi.org/10.1089/dia.2023.0013
[10]  Toyoda, M., Murata, T., Saito, N., Kimura, M., Takahashi, H., Ishida, N., et al. (2021) Assessment of the Accuracy of an Intermittent-Scanning Continuous Glucose Monitoring Device in Patients with Type 2 Diabetes Mellitus Undergoing Hemodialysis (AIDT2H) Study. Therapeutic Apheresis and Dialysis, 25, 586-594.
https://doi.org/10.1111/1744-9987.13618
[11]  Narasaki, Y., Kalantar-Zadeh, K., Daza, A.C., You, A.S., Novoa, A., Peralta, R.A., et al. (2024) Accuracy of Continuous Glucose Monitoring in Hemodialysis Patients with Diabetes. Diabetes Care, 47, 1922-1929.
https://doi.org/10.2337/dc24-0635
[12]  Villard, O., Breton, M.D., Rao, S., Voelmle, M.K., Fuller, M.R., Myers, H.E., et al. (2022) Accuracy of a Factory-Calibrated Continuous Glucose Monitor in Individuals with Diabetes on Hemodialysis. Diabetes Care, 45, 1666-1669.
https://doi.org/10.2337/dc22-0073
[13]  Matzka, M., Ørtenblad, N., Lenk, M. and Sperlich, B. (2024) Accuracy of a Continuous Glucose Monitoring System Applied Before, During, and after an Intense Leg-Squat Session with Low and High-Carbohydrate Availability in Young Adults without Diabetes. European Journal of Applied Physiology, 124, 3557-3569.
https://doi.org/10.1007/s00421-024-05557-5
[14]  Villa-Tamayo, M.F., Builes-Montaño, C.E., Ramirez-Rincón, A., Carvajal, J. and Rivadeneira, P.S. (2022) Accuracy of an Off-Label Transmitter and Data Manager Paired with an Intermittent Scanned Continuous Glucose Monitor in Adults with Type 1 Diabetes. Journal of Diabetes Science and Technology, 18, 701-708.
https://doi.org/10.1177/19322968221133405
[15]  Bauhaus, H., Erdogan, P., Braun, H. and Thevis, M. (2023) Continuous Glucose Monitoring (CGM) in Sports—A Comparison between a CGM Device and Lab-Based Glucose Analyser under Resting and Exercising Conditions in Athletes. International Journal of Environmental Research and Public Health, 20, Article 6440.
https://doi.org/10.3390/ijerph20156440
[16]  Ólafsdóttir, A.F., Andelin, M., Saeed, A., Sofizadeh, S., Hamoodi, H., Jansson, P., et al. (2022) Performance of Dexcom G5 and Freestyle Libre Sensors Tested Simultaneously in People with Type 1 or 2 Diabetes and Advanced Chronic Kidney Disease. World Journal of Clinical Cases, 10, 7794-7807.
https://doi.org/10.12998/wjcc.v10.i22.7794
[17]  Eichenlaub, M., Waldenmaier, D., Wehrstedt, S., Pleus, S., Link, M., Jendrike, N., et al. (2025) Performance of Three Continuous Glucose Monitoring Systems in Adults with Type 1 Diabetes. Journal of Diabetes Science and Technology, 2025, 1-10.
https://doi.org/10.1177/19322968251315459
[18]  Pleus, S., Stuhr, A., Link, M., Haug, C. and Freckmann, G. (2021) Variation of Mean Absolute Relative Differences of Continuous Glucose Monitoring Systems Throughout the Day. Journal of Diabetes Science and Technology, 16, 649-658.
https://doi.org/10.1177/1932296821992373
[19]  Sterne, J.A., Hernán, M.A., Reeves, B.C., Savović, J., Berkman, N.D., Viswanathan, M., et al. (2016) ROBINS-I: A Tool for Assessing Risk of Bias in Non-Randomised Studies of Interventions. British Medical Journal, 355, i4919.
https://doi.org/10.1136/bmj.i4919
[20]  Jiang, Q.Q., Zhang, Y., Qiao, L., Zha, Q.H., Xie, L. and Luo, Z.Z. (2022) A Cross-Sectional Survey and Analysis of Influencing Factors of Humanistic of the Current Status of Humanistic Care Ability of Burn Specialist Nurses. Chinese Journal of Burns and Wound Repair, 38, 1073-1078.
[21]  Sharifuzzaman, M., Shin, Y.D., Yoo, J., Reza, M.S., Kim, Y. and Park, J.Y. (2023) An Oxygen-Insensitive and Minimally Invasive Polymeric Microneedle Sensor for Continuous and Wide-Range Transdermal Glucose Monitoring. Talanta, 263, Article 124747.
https://doi.org/10.1016/j.talanta.2023.124747
[22]  Fedulovs, A., Janevica, J., Kruzmane, L. and Sokolovska, J. (2024) Glucose Control and Variability Assessed by Continuous Glucose Monitoring in Patients with Type 1 Diabetes and Diabetic Kidney Disease. Biomedical Reports, 22, Article No. 23.
https://doi.org/10.3892/br.2024.1901
[23]  He, J., Cao, X., Liu, H., Liang, Y., Chen, H., Xiao, M., et al. (2023) Power and Sensitivity Management of Carbon Nanotube Transistor Glucose Biosensors. ACS Applied Materials & Interfaces, 16, 1351-1360.
https://doi.org/10.1021/acsami.3c17309
[24]  Pradhan, R., Chimene, D., Ko, B.S., Goncharov, A., Ozcan, A. and McShane, M.J. (2024) Insertable Biomaterial-Based Multianalyte Barcode Sensor toward Continuous Monitoring of Glucose and Oxygen. ACS Sensors, 9, 6060-6070.
https://doi.org/10.1021/acssensors.4c01926
[25]  Tong, X., Jiang, T., Yang, J., Song, Y., Ao, Q., Tang, J., et al. (2025) Continuous Glucose Monitoring (CGM) System Based on Protein Hydrogel Anti-Biofouling Coating for Long-Term Accurate and Point-of-Care Glucose Monitoring. Biosensors and Bioelectronics, 277, Article 117307.
https://doi.org/10.1016/j.bios.2025.117307
[26]  Zhu, W., Yu, H., Pu, Z., Guo, Z., Zheng, H., Li, C., et al. (2023) Effect of Interstitial Fluid Ph on Transdermal Glucose Extraction by Reverse Iontophoresis. Biosensors and Bioelectronics, 235, Article 115406.
https://doi.org/10.1016/j.bios.2023.115406
[27]  Tingsarat, W., Buranasupkajorn, P., Khovidhunkit, W., Boonchaya-anant, P. and Laichuthai, N. (2021) The Accuracy of Continuous Glucose Monitoring in the Medical Intensive Care Unit. Journal of Diabetes Science and Technology, 16, 1550-1554.
https://doi.org/10.1177/19322968211027590
[28]  Šoupal, J., Kao, K., Brandner, L., Grunberger, G. and Prázný, M. (2023) Low Initial Adherence with Flash Glucose Monitoring Is Not a Predictor of Long-Term Glycemic Outcomes: Longitudinal Analysis of the Association between Experience, Adherence, and Glucose Control for Freestyle Libre Users. Diabetes Therapy, 14, 1231-1240.
https://doi.org/10.1007/s13300-023-01422-4
[29]  Wright, J.J., Williams, A.J., Friedman, S.B., Weaver, R.G., Williams, J.M., Hodge, E., et al. (2022) Accuracy of Continuous Glucose Monitors for Inpatient Diabetes Management. Journal of Diabetes Science and Technology, 17, 1252-1255.
https://doi.org/10.1177/19322968221076562
[30]  Cornet, S., Moranne, O., Jouret, F., Parotte, M.C., Georges, B., Godon, E., et al. (2024) Performance of an Interstitial Glucose Monitoring Device in Patients with Type 1 Diabetes during Haemodialysis. Clinical Kidney Journal, 17, sfae045.
https://doi.org/10.1093/ckj/sfae045
[31]  Henry, Z., Villar, E., Chauvet, C., Belloi, A., Prunescu, I., Doroszewski, F., et al. (2024) Continuous Glucose Monitoring with Freestyle Libre PRO Sensor in Patients with Type 2 Diabetes and End-Stage Renal Failure on Haemodialysis (FSLPRO-DIAL Pilot Study). Acta Diabetologica, 61, 1537-1541.
https://doi.org/10.1007/s00592-024-02323-z
[32]  Ling, J., Ng, J.K.C., Chan, J.C.N. and Chow, E. (2022) Use of Continuous Glucose Monitoring in the Assessment and Management of Patients with Diabetes and Chronic Kidney Disease. Frontiers in Endocrinology, 13, Article 869899.
https://doi.org/10.3389/fendo.2022.869899
[33]  Da Prato, G., Pasquini, S., Rinaldi, E., Lucianer, T., Donà, S., Santi, L., et al. (2021) Accuracy of CGM Systems during Continuous and Interval Exercise in Adults with Type 1 Diabetes. Journal of Diabetes Science and Technology, 16, 1436-1443.
https://doi.org/10.1177/19322968211023522
[34]  Mason, L.J., Hartwig, T. and Greene, D. (2024) Validating the Use of Continuous Glucose Monitors with Nondiabetic Recreational Runners. International Journal of Sports Physiology and Performance, 19, 1307-1313.
https://doi.org/10.1123/ijspp.2024-0102
[35]  Maytham, K., Hagelqvist, P.G., Engberg, S., Forman, J.L., Pedersen-Bjergaard, U., Knop, F.K., et al. (2024) Accuracy of Continuous Glucose Monitoring during Exercise-Related Hypoglycemia in Individuals with Type 1 Diabetes. Frontiers in Endocrinology, 15, Article 1352829.
https://doi.org/10.3389/fendo.2024.1352829
[36]  Ng, J.K.C., Ling, J., Luk, A.O.Y., Lau, E.S.H., Ma, R.C.W., Li, P.K.T., et al. (2023) Evaluation of a Fourth-Generation Subcutaneous Real-Time Continuous Glucose Monitor (CGM) in Individuals with Diabetes on Peritoneal Dialysis. Diabetes Care, 46, 1191-1195.
https://doi.org/10.2337/dc22-2348
[37]  Gu, J., Zhao, Z., Li, H., Li, B., Chen, S., Cao, Y., et al. (2025) Accuracy of Freestyle Libre Continuous Glucose Monitoring System in Critically Ill Patients after Cardiac Surgery. Journal of Cardiothoracic Surgery, 20, Article No. 75.
https://doi.org/10.1186/s13019-024-03229-1
[38]  Price, C.E., Fanelli, J.E., Aloi, J.A., Anzola, S.C., Vishneski, S.R., Saha, A.K., et al. (2023) Feasibility of Intraoperative Continuous Glucose Monitoring: An Observational Study in General Surgery Patients. Journal of Clinical Anesthesia, 87, Article 111090.
https://doi.org/10.1016/j.jclinane.2023.111090
[39]  Shin, J., Jo, E., Woo, H.Y., Cho, A., Ko, M., Kim, S., et al. (2024) Perioperative Glucose Monitoring with Continuous Glucose Monitors Identifies Risk Factors for Post-Transplant Diabetes Mellitus in Kidney Transplant Recipients. Scientific Reports, 14, Article No. 21240.
https://doi.org/10.1038/s41598-024-72025-7