贵阳龙洞堡机场自动气象观测系统供电设备配置研究
Research on the Power Supply Equipment Configuration of the Automatic Meteorological Observation System at Guiyang Longdongbao Airport

DOI: 10.12677/iae.2025.132024, PP. 174-181

Keywords: 贵阳龙洞堡机场,自动气象观测系统,供电设备,不间断电源
Guiyang Longdongbao Airport
, Automatic Meteorological Observation System, Power Supply Equipment, Uninterruptible Power Supply

Full-Text   Cite this paper   Add to My Lib

Abstract:

贵阳龙洞堡机场作为贵州省的重要航空枢纽,其运行效率和安全性对区域经济发展具有重要影响。民航自动气象观测系统是机场运行的核心环节之一,其稳定性和可靠性直接依赖于供电设备的合理配置。本文以贵阳龙洞堡机场为例,针对自动气象观测系统的供电设备配置展开研究,重点分析其电力需求特点、负载特性及供电可靠性要求。基于实际运行情况和理论分析,本文探讨了适用于该系统的供电设备配置方案,并结合实际运行中存在的问题提出改进建议。研究结果可为贵阳龙洞堡机场供电系统的升级改造提供理论依据,同时也可为其他类似机场的供电设备配置提供参考,对提升机场运行安全性和可靠性具有重要意义。
As an important aviation hub in Guizhou Province, the operational efficiency and safety of Guiyang Longdongbao Airport have a significant impact on regional economic development. The civil aviation automatic weather observation system is one of the core components of airport operation, and its stability and reliability directly depend on the reasonable configuration of power supply equipment. This article takes Guiyang Longdongbao Airport as an example to study the configuration of power supply equipment for automatic weather observation systems, focusing on analyzing their power demand characteristics, load characteristics, and power supply reliability requirements. Based on actual operating conditions and theoretical analysis, this article explores the power supply equipment configuration scheme applicable to the system, and proposes improvement suggestions in combination with the problems existing in actual operation. The research results can provide theoretical basis for the upgrading and renovation of the power supply system at Guiyang Longdongbao Airport, and also provide reference for the configuration of power supply equipment in other similar airports, which is of great significance for improving the safety and reliability of airport operation.

References

[1]  赵宁宁. 民航机场自动气象观测系统的维护及故障处理探讨[J]. 信息通信, 2018(5): 281-282.
[2]  中国民用航空局. 民用航空自动气象观测系统技术规范AP-117-TM-2018-03R1 [S]. 北京: 中国民用航空局空管行业管理办公室, 2018.
[3]  中国民用航空局. 民用航空机场气象台建设指南AP-117-TM-2012-01 [S]. 北京: 中国民用航空局空管行业管理办公室, 2012.
[4]  高峻岭. UPS电源设备的选配和日常维护[J]. 电信技术, 2002(5): 22-24.
[5]  张庆忠, 邵长靖, 倪培亮, 等. 高效节能的电动机不间断电源系统MUPS [J]. 电世界, 2010, 51(8): 16-18.
[6]  黄赟, 沈嘉琪, 谢志桐. 通信设备的供电模式研究探讨[C]//中国通信学会通信电源委员会. 通信电源新技术论坛——2010通信电源学术研讨会论文集. 上海: 中国移动上海公司传动中心浦东动力部, 2010: 5.