全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

4-硝基苯肼薄膜对丙酮气体的检测研究
Research on the Detection of Acetone Gas Using 4-Nitrobenzene Hydrazine Films

DOI: 10.12677/ms.2025.154071, PP. 660-667

Keywords: 丙酮气体,4-硝基苯肼,气敏薄膜
Acetone Gas
, 4-Nitrophenyl Hydrazine, Gas-Sensitive Film

Full-Text   Cite this paper   Add to My Lib

Abstract:

本文利用4-硝基苯肼制备出以玻璃片为基底的气敏薄膜,通过对吸收光谱以及拉曼光谱的分析对气敏薄膜对丙酮气体的气敏特性进行验证与分析,并对其反应机理进行分析,并且所制备的气敏薄膜与丙酮气体反应前后在空气环境中均具有良好的稳定性。本文最终对丙酮气体检测提出了一种新方法。
In this paper, 4-nitrophenylhydrazine was used to prepare a gas-sensitive film based on glass sheets, and the gas-sensitive characteristics of the gas-sensitive film to acetone gas were verified and analyzed by the analysis of absorption spectroscopy and Raman spectroscopy, and its reaction mechanism was analyzed, and the prepared gas-sensitive film had good stability in the air environment before and after the reaction with acetone gas. Finally, a new method for acetone gas detection is proposed.

References

[1]  张素芳. 面向丙酮检测的铁酸镍基气体传感器研究[D]: [硕士学位论文]. 长春: 吉林大学, 2020.
[2]  Wang, C. and Sahay, P. (2009) Breath Analysis Using Laser Spectroscopic Techniques: Breath Biomarkers, Spectral Fingerprints, and Detection Limits. Sensors, 9, 8230-8262.
https://doi.org/10.3390/s91008230
[3]  Miekisch, W., Schubert, J.K. and Noeldge-Schomburg, G.F.E. (2004) Diagnostic Potential of Breath Analysis—Focus on Volatile Organic Compounds. Clinica Chimica Acta, 347, 25-39.
https://doi.org/10.1016/j.cccn.2004.04.023
[4]  Bhardwaj, R. and Hazra, A. (2021) MXene-Based Gas Sensors. Journal of Materials Chemistry C, 9, 15735-15754.
https://doi.org/10.1039/d1tc04085e
[5]  Nakhleh, M.K., Amal, H., Jeries, R., et al. (2017) Diagnosis and Classification of 17 Diseases from 1404 Subjects via Pattern Analysis of Exhaled Molecules. ACS Nano, 11, 112-125.
[6]  Phillips, M., Herrera, J., Krishnan, S., Zain, M., Greenberg, J. and Cataneo, R.N. (1999) Variation in Volatile Organic Compounds in the Breath of Normal Humans. Journal of Chromatography B: Biomedical Sciences and Applications, 729, 75-88.
https://doi.org/10.1016/s0378-4347(99)00127-9
[7]  Wang, D., Zhang, F., Prabhakar, A., Qin, X., Forzani, E.S. and Tao, N. (2020) Colorimetric Sensor for Online Accurate Detection of Breath Acetone. ACS Sensors, 6, 450-453.
https://doi.org/10.1021/acssensors.0c02025
[8]  Mohar, M. (2019) 2,4,7‐Triaminofluorenone as a Multi‐Analyte Colorimetric Sensor of Fluoride, Acetone Vapor, and Other Harmful Compounds. ChemistrySelect, 4, 8061-8067.
https://doi.org/10.1002/slct.201901923
[9]  Yu, J.J., et al. (2021) Detection of Transdermal Biomarkers Using Gradient-Based Colorimetric Array Sensor. Biosensors & Bioelectronics, 195, Article ID: 113650.
[10]  Ito, K., Kawamura, N., Suzuki, Y. and Yamada Maruo, Y. (2020) Colorimetric Detection of Gaseous Acetone Based on a Reaction between Acetone and 4-Nitrophenylhydrazine in Porous Glass. Microchemical Journal, 159, Article ID: 105428.
https://doi.org/10.1016/j.microc.2020.105428
[11]  Wang, Z., Sun, J. and Zhang, J. (2022) Breath Acetone Sensors Based on Metal Oxide Semiconductors: A Review. Sensors, 22, Article No. 1653.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133