As cataract surgery progresses from “restoration of sight” to “refractive correction”, precise prediction of intraocular lens (IOL) power is critical for enhancing postoperative visual quality in patients. IOL power calculation methods have evolved and innovated throughout time, from early theoretical and regression formulas to nonlinear formulas for estimating effective lens position (ELP), multivariable formulas, and innovative formulas that use optical principles and AI-based online formulas. This paper thoroughly discusses the development and iteration of traditional IOL calculation formulas, the emergence of new IOL calculation formulas, and the selection of IOL calculation formulas for different patients in the era of refractive cataract surgery, serving as a reference for “personalized” IOL implantation in clinical practice.
References
[1]
Bamdad, S., Bolkheir, A., Sedaghat, M.R., et al. (2018) Changes in Corneal Thickness and Corneal Endothelial Cell Density after Phacoemulsification Cataract Surgery: A Double-Blind Randomized Trial. Electron Physician, 10, 6616-6623. https://doi.org/10.19082/6616
[2]
Lee, C.M. and Afshari, N.A. (2017) The Global State of Cataract Blindness. Current Opinion in Ophthalmology, 28, 98-103. https://doi.org/10.1097/ICU.0000000000000340
[3]
Retzlaff, J.A., Sanders, D.R. and Kraff, M.C. (1990) Development of the SRK/T Intraocular Lens Implant Power Calculation Formula. Journal of Cataract & Refractive Surgery, 16, 333-340. https://doi.org/10.1016/S0886-3350(13)80705-5
[4]
Olsen, T. (2007) Calculation of Intraocular Lens Power: A Review. Acta Ophthalmologica, 85, 472-485.
[5]
Sanders, D.R., Retzlaff, J. and Kraff, M.C. (1988) Comparison of the SRK II™ Formula and Other Second Generation Formulas. Journal of Cataract & Refractive Surgery, 14, 136-141. https://doi.org/10.1016/S0886-3350(88)80087-7
[6]
Holladay, J.T., Prager, T.C., Chandler, T.Y., et al. (1988) A Three-Part System for Refining Intraocular Lens Power Calculations. Journal of Cataract & Refractive Surgery, 14, 17-24. https://doi.org/10.1016/S0886-3350(88)80059-2
[7]
Sanders, D.R., Retzlaff, J.A., Kraff, M.C., et al. (1990) Comparison of the SRK/T Formula and Other Theoretical and Regression Formulas. Journal of Cataract & Refractive Surgery, 16, 341-346. https://doi.org/10.1016/S0886-3350(13)80706-7
[8]
Hoffer, K.J. (1993) The Hoffer Q Formula: A Comparison of Theoretic and Regression Formulas. Journal of Cataract & Refractive Surgery, 19, 700-712. https://doi.org/10.1016/S0886-3350(13)80338-0
[9]
Shen, Y., Wang, Y., Zhu, B., et al. (2017) Comparison of Five Intraocular Lens Calculation Formulas in Eyes with Short Axial Length. Journal of Shanghai Jiao Tong University (Medical Science), 37, 26-29.
[10]
Haigis, W., Lege, B., Miller, N., et al. (2000) Comparison of Immersion Ultrasound Biometry and Partial Coherence Interferometry for Intraocular Lens Calculation According to Haigis. Graefes Archive for Clinical & Experimental Ophthalmology, 238, 765-773. https://doi.org/10.1007/s004170000188
[11]
Barrett and Graham, D. (1993) An Improved Universal Theoretical Formula for Intraocular Lens Power Prediction. Journal of Cataract & Refractive Surgery, 19, 713-720. https://doi.org/10.1016/S0886-3350(13)80339-2
[12]
Olsen, T. and Hoffmann, P.C. (2014) Constant: New Concept for Ray Tracing-assisted Intraocular Lens Power Calculation. Journal of Cataract & Refractive Surgery, 40, 764-773. https://doi.org/10.1016/j.jcrs.2013.10.037
[13]
Ladas, J.G., Siddiqui, A.A., Devgan, U., et al. (2015) A 3-D “Super Surface” Combining Modern Intraocular Lens Formulas to Generate a “Super Formula” and Maximize Accuracy. JAMA Ophthalmology, 133, 1431-1436. https://doi.org/10.1001/jamaophthalmol.2015.3832
[14]
Zhang, J., Wang, W., Liu, Z., et al. (2021) Accuracy of New-Generation Intraocular lens Calculation Formulas in Eyes Undergoing Combined Silicone Oil Removal and Cataract Surgery. Journal of Cataract and Refractive Surgery, 47, 593-598. https://doi.org/10.1097/j.jcrs.0000000000000509
[15]
Yu, Y. and Lv, Y. (2011) Calculation of Intraocular Lens Power after Excimer Laser Refractive Corneal Surgery. Chinese Journal of Ophthalmic Optics and Visual Science, 13, 71-75.
[16]
Olsen, T. (2007) Calculation of Intraocular Lens Power: A Review. Acta Ophthalmologica, 85, 472-485.
[17]
Rong, X., He, W., Zhu, Q., et al. (2019) Intraocular Lens Power Calculation in Eyes with Extreme Myopia: Comparison of Barrett Universal II, Haigis, and Olsen formulas. Journal of Cataract & Refractive Surgery, 45, 732-737. https://doi.org/10.1016/j.jcrs.2018.12.025
[18]
Gavin, E.A. and Hammond, C.J. (2008) Intraocular Lens Power Calculation in Short Eyes. Eye, 22, 935-938. https://doi.org/10.1038/sj.eye.6702774
[19]
Wang, Q. and Ma, X. (2019) Analysis of the Accuracy of Intraocular Lens Measurement Formulas in Short Axial Length Eyes. China Medical Device Information, 25, 21-22.
[20]
Voytsekhivskyy, O.V., Hoffer, K.J., Savini, G., et al. (2021) Clinical Accuracy of 18 IOL Power Formulas in 241 Short Eyes. Current Eye Research, 46, 1832-1843. https://doi.org/10.1080/02713683.2021.1933056
[21]
Yang, Z., Shi, Q., Wu, H., et al. (2022) Analysis of the Accuracy of Four Intraocular Lens Power Calculation Formulas in Predicting Postoperative Refraction in Cataract Patients with Short Axial Length. Contemporary Medicine, 28, 89-92.
[22]
Wang, L. (2019) Clinical Progress in the Surgical Treatment of High Myopia Cataract. Journal of Integrated Traditional Chinese and Western Medicine in Shenzhen, 29, 194-196.
[23]
Yildiz, A. (2020) The Comparison of the Intraocular Lens Power Calculation Formulas in Long Eyes. Journal of the Pakistan Medical Association, 70, 1173-1176. https://doi.org/10.5455/JPMA.15406
[24]
Gokce, S.E., Zeiter, J.H., Weikert, M.P., et al. (2017) Intraocular Lens Power Calculations in Short Eyes Using 7 Formulas. Journal of Cataract & Refractive Surgery, 43, 892-897. https://doi.org/10.1016/j.jcrs.2017.07.004
[25]
Yang, Z., Shi, Q., Wu, H., et al. (2021) Accuracy Analysis of Six Intraocular Lens Power Calculation Formulas in Cataract Eyes with Long Axial Length. China Modern Medicine, 28, 134-136.
[26]
Li, D., Yi, X, Zhang, M., et al. (2023) Predictive Analysis of Postoperative Refractive Power Using Different IOL Formulas in Cataract Patients with Long Axial Length. Journal of Xinjiang Medical University, 46, 201-205.
[27]
Wang, T., Wang, Q., Li, Y., et al. (2022) Comparison of the Accuracy of Five Calculation Formulas in Predicting Postoperative Refraction in Cataract Patients with Extreme Myopia. Practical Techniques for Prevention of Blindness, 17, 115-119+114+139.
[28]
Darcy, K., Gunn, D.J., Tavassoli, S., et al. (2020) Assessment of the Accuracy of New and Updated Intraocular Lens Power Calculation Formulas in 10930 Eyes from the UK National Health Service. Journal of Cataract & Refractive Surgery, 46, 2-7.
[29]
Liu, X., Yu, H. and Chen, S. (2018) Analysis of the Accuracy of Online Calculation of Intraocular Lens Power Using the Haigis-L Formula after Refractive Surgery for Myopia. Journal of Fujian Medical University, 52, 425-428.
[30]
Chen, X., Yuan, F. and Wu, L. (2016) Metaanalysis of Intraocular Lens Power Calculation after Laser Refractive Surgery Inmyopic Eyes. Journal of Cataract & Refractive Surgery, 42, 163-170. https://doi.org/10.1016/j.jcrs.2015.12.005
[31]
Abulafia, A., Hill, W.E., Koch, D.D., et al. (2016) Accuracy of the Barrett True-K Formula for Intraocular Lens Power Prediction after Laser in Situ Keratomileusis or Photorefractive Keratectomy for Myopia. Journal of Cataract and Refractive Surgery, 42, 363-369. https://doi.org/10.1016/j.jcrs.2015.11.039