冬季水冲洗车排水防寒措施试验研究
Experimental Study on Winter Water Washing Vehicle Drainage and Cold Prevention Measures

DOI: 10.12677/met.2024.135052, PP. 446-453

Keywords: 接触网,绝缘子,水冲洗车,快速排水,防冻
Contact Network
, Insulator, Water Washing Car, Rapid Drainage, Antifreeze

Full-Text   Cite this paper   Add to My Lib

Abstract:

为了解决接触网绝缘子水冲洗车排水时间长,冬季排水困难,且排水过程中容易结冻的问题,文章提出采用电伴热保温措施和一种高压气流辅助快速排水的方案,在水冲洗车作业完毕后,通过“一键排水”的自动化控制方式,打开系统排水阀门,利用高压风机约260 mbar的压力对整个水冲洗系统管道内进行加压,实现快速排水。经过设计试验方案验证:通常自然排水时间长达30分钟左右;而经过高压气流辅助排水,排水时间只需要5分钟时间。试验证明水冲洗系统排水时引入高压气流可使排水效率大幅提高,且高压风机产生的热风高达64℃,更有利于冬季排水时防止结冻现象产生。
In order to solve the problems of long drainage time, difficult drainage in winter, and easy freezing during the drainage process of the contact network insulator water flushing vehicle, it is proposed to adopt electric heat tracing insulation measures and a high-pressure airflow assisted rapid drainage scheme. After the water flushing vehicle operation is completed, the system drainage valve is opened through the automatic control method of “one click drainage”, and the entire water flushing system pipeline is pressurized using a high-pressure fan with a pressure of about 260 mbar to achieve rapid drainage. After verification of the design test plan, it was found that the natural drainage time is usually up to about 30 minutes. After high-pressure airflow assisted drainage, the drainage time only takes 5 minutes. Experiments have shown that introducing high-pressure airflow during water flushing system drainage can significantly improve drainage efficiency, and the high-pressure fan generates hot air up to 64℃, which is more conducive to preventing freezing during winter drainage.

References

[1]  关志成, 王绍武, 梁曦东, 等. 我国电力系统绝缘子污闪事故及其对策[J]. 高压电技术, 2000(6): 37-39.
[2]  卫永刚. KJ-D接触网绝缘子水冲洗车在朔黄铁路的应用及改进建议[J]. 黑龙江科技信息, 2017(20): 143-145.
[3]  张巍. 绝缘子带电水冲洗车浅析[J]. 机械管理开发, 2012(1): 95-97.
[4]  王正旺, 白绍烈, 庞转棠, 等. 电力污闪事故的气象条件分析[J]. 自然灾害学报, 2005(5): 136-140.
[5]  马军卫. 低温环境供水管道防冻解决方案[J]. 设备管理与维修, 2021(5): 142-144.
[6]  林立彬, 廉海浔, 刘胜军, 等. 公路隧道消防管道保温措施研究[J]. 隧道建设, 2022, 42(z2): 548-555.
[7]  张伟, 王汉林. 设备管道保温伴热方式分析及选择[J]. 大氮肥, 2022, 45(6): 410-413.
[8]  周洋洋, 刘焱. 电伴热技术在建筑给排水管道保温系统中的应用[J]. 给水排水, 2009, 45(S1): 358-360.
[9]  赵雪华. 管道快速排水瞬变流数值模拟研究[D]: [硕士学位论文]. 天津: 天津大学, 2019.
[10]  陈文玺, 夏建飞. 冬季给水管防冻保温公式应用研究[C]//中国建筑学会建筑给水排水研究分会. 中国建筑学会建筑给水排水研究分会第三届第二次全体会员大会暨学术交流会论文集. 2018: 1169-1175.