Wireless Preamplifier for the Specimen Current Mode Detector in a SEM

DOI: 10.4236/opj.2024.142002, PP. 23-28

Keywords: Scanning Electron Microscopy, Backscattered Electron Imaging, Wireless Specimen Current Preamplifier, Universal (SE/BSE) Dyukov Detector

Full-Text   Cite this paper   Add to My Lib

Abstract:

Using a scanning electron microscope (SEM) in the back-scattered electron (BSE) mode the composition of multi-element specimens may be determined based on the strong dependence of emission coefficient η on the average atomic number of elements Z. The output video signal of the usual BSE detectors is produced from their sensors, and the larger proportion of high-energy electrons with modified spectrum is added. Since η = is/ip (is and ip currents of specimen and probe), better accuracy must be achieved by direct measurements those currents on the specimen surface. Here, an experimental model of a current detector for a presented specimen is described. The cage is mounted on the carousel of the moving specimen stage. The input of the preamplifier is connected to the specimen holder in the form of a disk, the diameter of which is 12 mm. When the probe along its surface scanned, the input potential begins to pulsate with a negative polarity. The output of this preamplifier is connected to a small light-emitting diode, which creates intensity-modulated radiation in the chamber. Thus created the light video signal will be picked up by the photomultiplier of the E-T detector. The modes of true SE and BSE are set by applying tens bias volts of various polarities to the specimens or the cage itself.

References

[1]  Reed, S.J.B. (2005) Electron Microprobe Analysis and Scanning Electron Microscopy in Geology. 2nd Edition, Cambridge University Press, Cambridge.
https://doi.org/10.1017/cbo9780511610561
[2]  Sánchez, E., Deluigi, M.T. and Castellano, G. (2012) Mean Atomic Number Quantitative Assessment in Backscattered Electron Imaging. Microscopy and Microanalysis, 18, 1355-1361.
https://doi.org/10.1017/s1431927612013566
[3]  Robinson, V.N.E. (1984) Electron Detectors Used for Imaging in the Scanning Electron Microscope. Scanning Electron Microscopy, 3, 187-195.
https://digitalcommons.usu.edu/electron/vol3/iss1/19
[4]  Dyukov, V.G. and Nepijko, S.A. (2020) Progress in Determining of Compound Composition by BSE Imaging in a SEM and the Relevant Detector Disadvantages. Advances in Imaging and Electron Physic, 215, 107-140.
https://doi.org/10.1016/bs.aiep.2020.06.004
[5]  Štubian, M., Bobek, J., Setvin, M., Diebold, U. and Schmid, M. (2020) Fast Low-Noise Transimpedance Amplifier for Scanning Tunneling Microscopy and Beyond. Review of Scientific Instruments, 91, Article 074701.
https://doi.org/10.1063/5.0011097

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133