Background: Epidural anesthesia is an effective intervention to treat labor pain and provide analgesia for orthopedic procedures. A rare complication of this technique is epidural catheter retention. Case Presentation: In this case report, we present an otherwise healthy 21-year-old G2P0010 woman at 39 weeks and 3 days gestation whose anesthetic management was complicated by a symptomatic retained epidural catheter fragment. Computed tomography (CT) imaging of her spine showed the fractured catheter within her paraspinal muscles and neurosurgery recommended no surgical intervention at that time. The patient reported resolution of back pain while in the postpartum unit which she continues to endorse two weeks after discharge. Conclusion: Retained epidural catheter is a medical emergency that requires immediate imaging and neurological evaluation. While magnetic resonance imaging is typically regarded as the standard imaging modality for this complication, in epidural sets that contain metallic components, we suggest using CT to avoid the risk of thermal nerve damage. In cases where the patient does not report any acute complaints, nonsurgical management may be appropriate but close follow-up is required to monitor for catheter migration.
References
[1]
Hawkins, J.L. (2010) Epidural Analgesia for Labor and Delivery. New England Journal of Medicine, 362, 1503-1510. https://doi.org/10.1056/nejmct0909254
[2]
(2016) Practice Guidelines for Obstetric Anesthesia: An Updated Report by the American Society of Anesthesiologists Task Force on Obstetric Anesthesia and the Society for Obstetric Anesthesia and Perinatology. Anesthesiology, 124, 270-300. https://pubs.asahq.org/anesthesiology/article/124/2/270/12693/Practice-Guidelines-for-Obstetric-AnesthesiaAn
[3]
Clivatti, J., Siddiqui, N., Goel, A., Shaw, M., Crisan, I. and Carvalho, J.C.A. (2013) Quality of Labour Neuraxial Analgesia and Maternal Satisfaction at a Tertiary Care Teaching Hospital: A Prospective Observational Study. Canadian Journal of Anesthesia, 60, 787-795. https://doi.org/10.1007/s12630-013-9976-9
[4]
Parnass, S.M. and Schmidt, K.J. (1990) Adverse Effects of Spinal and Epidural Anaesthesia. Drug Safety, 5, 179-194. https://doi.org/10.2165/00002018-199005030-00003
[5]
Sharma, R., Setlur, R., Bhargava, A. and Vardhan, S. (2007) Walking Epidural: An Effective Method of Labour Pain Relief. Medical Journal Armed Forces India, 63, 44-46. https://doi.org/10.1016/s0377-1237(07)80107-9
[6]
Merrer, J., Bonnet, M., Blondel, B., Tafflet, M., Khoshnood, B., Le Ray, C., et al. (2021) Predictors of Incomplete Maternal Satisfaction with Neuraxial Labor Analgesia: A Nationwide Study. Anaesthesia Critical Care & Pain Medicine, 40, Article 100939. https://doi.org/10.1016/j.accpm.2021.100939
[7]
Eltzschig, H.K., Lieberman, E.S. and Camann, W.R. (2003) Regional Anesthesia and Analgesia for Labor and Delivery. New England Journal of Medicine, 348, 319-332. https://doi.org/10.1056/nejmra021276
[8]
Jongleux, E.F., Miller, R. and Freeman, A. (1998) An Entrapped Epidural Catheter in a Postpartum Patient. Regional Anesthesia and Pain Medicine, 23, 615-617. https://doi.org/10.1097/00115550-199823060-00018
[9]
Tarukado, K., Oda, T., Tono, O., Suetsugu, H. and Doi, T. (2015) A Retained Epidural Catheter Fragment Treated by Surgery. Asian Spine Journal, 9, 461-464. https://doi.org/10.4184/asj.2015.9.3.461
[10]
Gompels, B., Rusby, T. and Slater, N. (2022) Fractured Epidural Catheter with Retained Fragment in the Epidural Space—A Case Study and Proposed Management Algorithm. British Journal of AnaesthesiaOpen, 4, Article 100095. https://doi.org/10.1016/j.bjao.2022.100095
[11]
Mitra, R. and Fleischmann, K. (2007) Management of the Sheared Epidural Catheter: Is Surgical Extraction Really Necessary? Journal of Clinical Anesthesia, 19, 310-314. https://doi.org/10.1016/j.jclinane.2006.11.005
[12]
Reena and Vikram, A. (2017) Fracture of Epidural Catheter: A Case Report and Review of Literature. Saudi Journal of Anaesthesia, 11, 108-110.
[13]
Walia, S., Pisal, T., Kandari, A. and Jivrajani, P. (2022) Minimally Invasive Surgery to Remove a Broken and Retained Epidural Catheter Fragment. Cureus, 14, e25255. https://doi.org/10.7759/cureus.25255
[14]
Hippalgaonkar, A., Kudalkar, A., Gaikwad, S., Modak, S., Gupta, H. and Tendolkar, B. (2017) Successful Management of a Broken Epidural Catheter. Saudi Journal of Anaesthesia, 11, 228-231. https://doi.org/10.4103/1658-354x.203029
[15]
Alfadhel, A., Turkistany, H., Alkinani, A.A., Kabbani, N. and Alabdullah, A.F. (2024) Broken Epidural Catheter after Vaginal Delivery. Cureus, 16, e55013. https://doi.org/10.7759/cureus.55013
[16]
Subith, S., Dussa, K.R., Kokate, S., Mukadam, M., Zafar, S. and Choudhari, A. (2024) When the Unexpected Happens: The Intriguing Retrieval of a Broken Epidural Catheter. Journal of Orthopaedic Case Reports, 14, 136-139. https://doi.org/10.13107/jocr.2024.v14.i02.4246
[17]
Siddappa, N.D., Kim, J. and Khandge, A.V. (2020) Full-Endoscopic Removal of Sheared Lumbar Epidural Catheter Fragment. World Neurosurgery, 137, 421-424. https://doi.org/10.1016/j.wneu.2020.02.111
[18]
Wang, Z., Xie, F. and Lin, W. (2019) Translaminar Endoscopic Approach to Remove a Broken Epidural Catheter Fragment. Journal of Clinical Anesthesia, 58, 57-58. https://doi.org/10.1016/j.jclinane.2019.04.019
[19]
Sulhan, S., Sadrameli, S.S., Barber, S., Holman, P., Britz, G. and Huang, M. (2022) Fractured Lumbar Drain Catheter Retrieval Using an Endoscopic Transforaminal Approach to the Lumbar Spine. Operative Neurosurgery, 23, e331-e334. https://doi.org/10.1227/ons.0000000000000378
[20]
Ugboma, S., Au-Truong, X., Kranzler, L.I., Rifai, S.H., Joseph, N.J. and Salem, M.R. (2002) The Breaking of an Intrathecally-Placed Epidural Catheter during Extraction. Anesthesia & Analgesia, 95, 1087-1089. https://doi.org/10.1097/00000539-200210000-00055
[21]
Palaria, U., Das, A. and Jakhund, C. (2018) Broken Epidural Catheter: What Next to do? Indian Journal of Clinical Anaesthesia, 5, 289-291.
[22]
Owens, S., Erturk, M.A., Ouanes, J.P., Murphy, J.D., Wu, C.L. and Bottomley, P.A. (2014) Evaluation of Epidural and Peripheral Nerve Catheter Heating during Magnetic Resonance Imaging. Regional Anesthesia and Pain Medicine, 39, 534-539. https://doi.org/10.1097/aap.0000000000000151
[23]
Coffey, R.J., Kalin, R. and Olsen, J.M. (2014) Magnetic Resonance Imaging Conditionally Safe Neurostimulation Leads. Neurosurgery, 74, 215-225. https://doi.org/10.1227/neu.0000000000000242
[24]
Blackshear, R.H., Gravenstein, N. and Radson, E. (1991) Tension Applied to Lumbar Epidural Catheters During Removal Is Much Greater with Patient Sitting Versus Lying. Anesthesiology, 75, A833. https://doi.org/10.1097/00000542-199109001-00832
[25]
Morris, G.N., Warren, B.B., Hanson, E.W., Mazzeo, F.J. and DiBenedetto, D.J. (1996) Influence of Patient Position on Withdrawal Forces during Removal of Lumbar Extradural Catheters. British Journal of Anaesthesia, 77, 419-420. https://doi.org/10.1093/bja/77.3.419
[26]
Sia-Kho, E. and Kudlak, T.T. (1992) How to Dislodge a Severely Trapped Epidural Catheter. Anesthesia & Analgesia, 74, 933. https://doi.org/10.1213/00000539-199206000-00031
[27]
Start, R.J., Greenberg, D.J. and Herman, N.L. (1992) Use of a Wilson Convex Frame in Removing “Irretrievable” Epidural Catheters. Anesthesia & Analgesia, 75, 305-306. https://doi.org/10.1213/00000539-199208000-00033
[28]
Pierre, H.L., Block, B.M. and Wu, C.L. (2003) Difficult Removal of a Wire-Reinforced Epidural Catheter. Journal of Clinical Anesthesia, 15, 140-141. https://doi.org/10.1016/s0952-8180(02)00516-0
[29]
Gadalla, F. (1992) Removal of a Tenacious Epidural Catheter. Anesthesia & Analgesia, 75, 1071-1072. https://doi.org/10.1213/00000539-199212000-00041